4-2
Master Communication
drive address
"Enter" button
2.Comand
"Esc" button
commands/settings
"Up" button
"Down" button
1.Er.Anz
extended display
The address is set via the control panel as follows:
1. change to "commands/settings" mode
standard display
e.g.:
1
F2002
Fig. 4-2:
Activating the "commands/settings" mode
2. select element "2.1 drive address" by means of "Up/Down" buttons,
then confirm by means of "Enter" button
3. set drive address by means of "Up/Down" buttons, then confirm by
means of "Enter" button
• first set tens digit:
→ the display reads "2.1.1 drive address"
• then set units digit:
→ the display reads "2.1.2 drive address"
Note:
The tens or units digit is accepted by pressing the "Enter"
button. To return press the "Esc" button.
"Enter" button
2.1 Adr.
"Esc" button
display
explanation:
Fig. 4-3:
Selecting and setting the drive address
Address Setting via Parameter
The drive address can also be set by writing the P-0-4025, Drive address
of master communication parameter. This is particularly interesting if
you administrate the axis data in centralized form in the control unit and
want to set the address from the control unit when replacing devices.
See also "Notes on How to Replace the Devices" in chapter "Handling,
Diagnostic and Service Functions"
MPH-02, MPB-02, MPD-02
2.Comand
commands/settings
press "Enter"
and "Esc"
extended display
buttons for
8 seconds
1.Er.Anz
"Enter" button
2.1.1
ZE
"Esc" button
set tens digit with "Up/Down"
buttons
accept with "Enter" button
display
display changes (flashes)
Y.Y
between "Y.Y" and "XXXXXXXX"
XXXXXXXX
ZE ... tens/units ("Zehner/Einer") digit of drive
address
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
"Up" button
2.1.2 ZE
set units digit with "Up/Down"
buttons
display