MPH-02, MPB-02, MPD-02
6.6
Power Supply
Possibilities of Power Supply for IndraDrive
Pertinent Parameters
Pertinent Diagnostic Messages
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Brief Description
For IndraDrive devices we basically distinguish two lines:
• modular line, consisting of supply unit and modular inverter
(IndraDrive M)
• non-modular line, so-called converter devices, including power supply
and inverter (IndraDrive C)
The power supply of the motors controlled via inverter is realized by a
direct voltage power bus (DC bus). In the case of the modular line, this
bus is supplied by the supply unit connected to the mains. Converters are
supplied by the mains connection via the integrated supply unit.
• S-0-0380, DC bus voltage
• P-0-0114, Undervoltage threshold
• P-0-0118, Power supply, configuration
• P-0-0460, Module group, control word
• P-0-0461, Module group, status word
• P-0-0806, Current mains voltage crest value
• P-0-0809, Properties of charging circuit
• P-0-0810, Minimum mains crest value
• P-0-0815, Nominal mains voltage crest value
• P-0-0833, Braking resistor threshold
• P-0-0844, Braking resistor load
• P-0-0858, Data of external braking resistor
• P-0-0859, Data of internal braking resistor
• P-0-0860, Control word of power section
• P-0-0861, Status word of power section
• E2026 Undervoltage in power section
• E2040 Device overtemperature 2 prewarning
• E2050 Device overtemp. Prewarning
• E2061 Device overload prewarning
• E2086 Prewarning supply module overload
• E2802 HW control of braking resistor
• E2810 Drive system not ready for operation
• E2814 Undervoltage in mains
• E2026 Undervoltage in power section
• E2818 Phase failure
• E2819 Mains failure
• E2820 Braking resistor overload prewarning
• E2829 Not ready for power on
• E8025 Overvoltage in power section
• E8028 Overcurrent in power section
• 8057 Device overload, current limit active
6-79
Drive Control