MPH-02, MPB-02, MPD-02
Notes on Commissioning
Example
How to Proceed for Additional
Licensing
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Handling, Diagnostic and Service Functions
Condition As Supplied
When a drive is delivered, there have basically all licensed functional
packages been enabled. The contents of the parameters P-0-2003 and P-
0-2004 describe the maximum usable scope of firmware functions
defined by the purchase order.
Note:
The firmware type printed on the firmware type plate has to
comply with the content of parameter S-0-0030, Manufacturer
version.
The content of parameter S-0-0030 can be read via the
standard control panel (see "Control Panel of the IndraDrive
Controllers").
The example below shows the relation between content of S-0-0030 and
type plate:
• Content of S-0-0030: FWA-INDRV*-MPH02V09-MS-CL-SNC-ML
• Imprint on type plate: FWA-INDRV*-MPH02V09-MS-CL-SNC-ML
Reducing the Functionality
The scaling is made by deactivating functional packages via an entry in
parameter P-0-2003, Selection of functional packages.
This change can be made by directly writing data to the parameter via the
master communication or the respective dialog in the "DriveTop"
commissioning tool.
The time of change is registered by an entry in P-0-2002, Oper. hours of
contr. sect. at change of functional packages.
Note:
A change in parameter P-0-2003 only takes effect after
repeated booting process. The active functional packages are
displayed in P-0-2004.
Additional Licensing (Expansion of Functionality)
If the firmware originally ordered and delivered does not contain all
required functions, it is possible to subsequently enable further functional
packages. This requires additional licensing that is not free of charge.
Note:
For test purposes it is possible to enable non-licensed
functional packages via P-0-2003 for a limited time (max.
2 weeks).
If you use a non-licensed functional package permanently, any
guarantee on the part of Bosch Rexroth will expire!
For additional licensing proceed as follows:
1. enable required functional packages in P-0-2003
2. boot drive again and verify content of P-0-2004
(content must comply with that of P-0-2003!)
3. see parameter S-0-0030, Manufacturer version for firmware type
and write it down; this parameter displays current firmware
configuration defined via P-0-2003
10-53