MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note:
The functionality of a drive-integrated PLC according to
IEC-61131-3 is only contained in the FWA-INDR*-MPH02VRS
firmware and requires the enabling of the additive functional
package "IndraMotion MLD-S".
See also sections:
• "Functional Packages" in chapter "System Overview"
• "Enabling of Functional Packages" in chapter "Handling,
Diagnostic and Service Functions"
Functional Features
The functional package "IndraMotion MLD-S" includes the following
general features/characteristic values:
• up to 4 preemptive user tasks are possible
• task types:
• periodic (min. 1 ms cycle time)
• free-running (permanently cyclic)
• event-controlled (min. 1 ms reaction time)
• memory resources:
• 512 kB program memory (with MMC) or
64 kB program memory (without MMC)
• 512 kByte data memory
• 250 bytes retain or 32 kbytes on MD1
• digital I/Os:
• 7...11 digital inputs, 0...4 digital outputs on X3
(CSH01.1 control section)
→ PLC and drive are sharing the inputs!
• 12 digital inputs, 8 digital outputs on MD1 (optional)
• 16 digital inputs, 16 digital outputs on PL
(as parallel master communication)
• 1 relay output on X3 (CSH01.1 control section)
→ PLC and drive are sharing the inputs!
• analog I/Os:
• 1 analog input (+/-10 V) on X3 (CSH01.1 control section)
• 2 analog outputs (0-5 V) on X3 (CSH01.1 control section)
•
analog inputs/outputs (+/-10 V) on MA1 (optional)
• other data:
• extensive debug possibilities:
Single-Step, Watch, Force/Write, Breakpoints, Powerflow
• performance of the programming system:
- IEC-61131 programming in IL, ST, SFC, CFC, LD, FBD
- Source Download, Online Change, Debugging, Offline Simulation
- libraries
- Debug Monitor for drive (PLC browser)
8-87
Drive Functions