240 en | SDI2 modules
Configuring the module
When installing a B42x IP Communicator, set the available configuration parameters properly
to ensure proper module operation.
The B426 Ethernet Communication Module is used to connect to the control panel over an
Ethernet network. Typical uses include PC front-end (automation) software packages, network
RPS connection for off-site programming, diagnostic troubleshooting, central station receiver
reporting, and history retrieval. Module bus supervision is enforced when the SDI2
communication module is used in a central station reporting route.
You can use one or both B426/B450 communication modules for central station reporting or
RPS communications. Optionally, you can use one of the B42x modules for communication
with automation software. While in this mode, you cannot use the module to communicate
with RPS nor with the central station.
Notice!
To prevent communication loss, the configuration sent to the control panel for the B42x
module takes effect after RPS disconnects from the control panel.
If the module is configured through the B42x configuration web interface to disable control
panel programming (that is, Panel Programming Enable is set to No), then RPS programming
of the B42x is accepted by the control panel, but not applied to the B42x. The Panel
Programming Enable parameter is not available in RPS.
14.4.1

Module Enclosure Tamper

Default: No - Disable
Selections:
Yes - Enable enclosure tamper input
No - Disable enclosure tamper input
This parameter enables the enclosure tamper switch input on the SDI2 module.
When the input is enabled and connected to a Bosch ICP-EZTS tamper switch installed in the
module enclosure, the control panel can create a tamper event when the enclosure door is
opened, or when the enclosure is removed from the wall.
RPS Menu Location
SDI2 > B42x IP Communicator > Enclosure Tamper
14.4.2

IPv6 Mode

Default: No
Selections:
This parameter configures IP communication for IPv6 (Internet Protocol version 6) or IPv4
(Internet Protocol version 4)
When IPv6 Enable is set to Yes, the IPv4 parameters are read only (grayed out and not
editable). Set DHCP/AutoIP enable to Yes.
When IPv6 Enable is set to No, the IPv6 parameters are read only (grayed out and not
editable).
RPS Menu Location
SDI2 > B42x IP Communicator > IPv6 Mode
14.4.3

IPv4 DHCP/AutoIP Enable

Default: Yes
2017.03 | 09 | F.01U.303.998
Yes - Enable IPv6
No - Disable IPv6 (Use IPv4 mode).
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.