Area; User Group Windows; User Group; Sunday Through Saturday - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

214 en | Schedules
11.1.12

Area #

Default: No
Selections:
Yes Activate the window in the specified area number.
No Disable the window in the specified area number.
This parameter determines whether a particular window activates in each of the control
panel's areas.
RPS Menu Location
Schedules > Open/Close Windows > Area #
11.2

User group windows

In this section, you can create up to eight User Group periods in which the passcodes for the
group chosen will be enabled. One user group can have multiple windows assigned to them
within a 24 hour period. Refer to User Group, in the Passcode Worksheet section of the
program to assign individuals to a group.
When you assign a User Group to one of the eight windows, all passcodes for the group are
enabled only for the period between the Enable Time and Disable Time for assigned User
Window #.
If a user is not assigned to a User Group or the number programmed for the user for User
Group is not assigned to a User Window # , the passcode for that user is enabled all the time.
11.2.1

User Group

Default:  (window #)
Selections:
0 = disabled
Enter a number to identify the group of users in this parameter.  When this window runs, the
user passcodes for this group are enabled / disabled.
You can assign a user group to more than one window in a 24 hour period, but the windows
must not overlap or exceed the midnight boundary.
RPS Menu Location
Schedules > User Group Windows > User Group
11.2.2

Sunday through Saturday

Default (Sunday through Saturday): No
Selections: Yes/No
In the seven weekday parameters, select the days of the week that the User Group window is
active.
To prevent the windows from activating on certain days of the year, set Xept Holiday to Yes,
and enable at least one holiday index. When Xept Holiday is set to Yes, the window executes
on the days of the week programmed unless the date is designated as a holiday by the
selected holiday index.
If opening and/or closing windows are only needed on certain days of the year, do not
program the windows to execute on any days of the week. Instead, set Xept Holiday to No,
and select a holiday index with the days of the year you want the window to be active.
2017.03 | 09 | F.01U.303.998
B9512G: 0 to 32
B8512G: 0 to 8
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.