The B810 RADION wireless module detects RF jamming (interference) when it is present. You
can use jamming Detection can be disabled for the B810 RADION Wireless module. The B820
Inovonics Wireless module also detects RF jamming (interference) when it is present.
Jamming Detection annot be disabled for the B820 Inovonics Wireless module.
RPS Menu Location
SDI2 Modules > Wireless Receiver > Enable Jamming Detection
14.8

Wireless Repeater

The wireless repeater modules are independent of the SDI2 bus. You can use a wireless
repeater to extend the range of the B820 Inovonics SDI2 Wireless Interface Module for an
installation site.
Capacity
The control panel supports two types of SDI2 wireless interface modules:
The type of wireless repeater must match the type of receiver. Choose the type of wireless
receiver before you configure any repeaters. The control panel supports up to 8 repeaters
simultaneously. All repeaters must be the same type.
Settings
You can configure the Enclosure Tamper on each of the wireless repeater modules.
Yes (default) = Enable enclosure tamper
No = Disable enclosure tamper.
You can configure the RFID for each of the Wireless Repeater modules.
There are no hardware switches on a wireless repeater. The location of the RFID within the
configuration table determines the wireless repeater number.
Notes
Even though RPS lists the Wireless Repeater configuration under the SDI2 Modules heading,
wireless repeaters are not physically connected to the SDI2 bus. You must configure a
wireless interface module as part of the system.
14.8.1

Module Enclosure Tamper

Default: No - Disable
Selections:
Yes - Enable enclosure tamper input
No - Disable enclosure tamper input
This parameter enables the enclosure tamper switch input on the SDI2 module.
When the input is enabled and connected to a Bosch ICP-EZTS tamper switch installed in the
module enclosure, the control panel can create a tamper event when the enclosure door is
opened, or when the enclosure is removed from the wall.
RPS Menu Location
SDI2 > Wireless Repeater > Enclosure Tamper
14.8.2

RADION RFID (B810)

Default: 0
Selection: 0, 11 - 167772156
This parameter provides a unique way for the Wireless Receiver and Wireless Repeaters to
identify what device is transmitting.