238 en | SDI2 modules
14

SDI2 modules

14.1

B208 Octo-input

The B208 Octo-input is a device that attaches to the SDI2 bus of the control panel. Each
module provides 8 independently monitored control loops.
Panel type
B9512G
B8512G
Tab. 14.1: Capacity
Settings
RPS supports the configuration of the Enclosure Tamper, page 238 on each of the Octo-input
modules.
Yes = Enable enclosure tamper
No = Disable enclosure tamper. The default setting is No.
Switch Settings
Refer to Hardware Switch Settings > B208 Octo-input Module switch settings, page 258
14.1.1

Enclosure Tamper

Default: No - Disable
Selections:
Yes - Enable enclosure tamper input
No - Disable enclosure tamper input
This parameter enables the enclosure tamper switch input on the SDI2 module.
When the input is enabled and connected to a Bosch ICP-EZTS tamper switch installed in the
module enclosure, the control panel can create a tamper event when the enclosure door is
opened, or when the enclosure is removed from the wall.
RPS Menu Location
SDI2 modules > B208 Octo-input > Enclosure Tamper
14.2

B299 POPEX

Attach the B299 POPEX device to the SDI2 bus of the control panel.
Panel type
B9512G
B8512G
Tab. 14.2: Capacity
Settings
RPS supports the configuration of the Enclosure Tamper, page 238 on each of the POPEX
modules.
Yes = Enable enclosure tamper.
No = Disable enclosure tamper. The default setting is No.
Switch Settings
Refer to Hardware Switch Settings > B299 POPEX Module switch settings, page 260
2017.03 | 09 | F.01U.303.998
Modules supported
59
9
Modules supported
6
1
Program Entry Guide