IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
A
Servo drives evenly distributed over the entire drive line
B
Servo drives evenly distributed at the end of the drive line
C
Servo drives evenly distributed starting at 20% of the drive line
D
Limit value A: hybrid cable length = 4 m with P
Limit value B: hybrid cable length = 18 m with P
Limit value C: hybrid cable length = 17 m with P
l
Maximum allowed hybrid cable length of a drive line
total_max
P
KMV output XD10 load (without cable losses)
42V
Fig. 7-16:
Maximum allowed hybrid cable length of a drive line
For exact calculations of the allowed hybrid cable lengths in limit
cases, please contact our sales representative.
The figure below shows P
depending on P
(KMV output XD10 load).
42V
(KMV power consumption from 24V supply)
N3(KMV)
R911335703_Edition 04 Bosch Rexroth AG
235/407
Notes on project planning
= 507 W
42V
= 489.5 W
42V
= 489.5 W
42V