hit counter script

Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual page 243

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
1
Segment length (l
2
Maximum allowed length in flexible cable track (l
3
Example: With a segment length of 60 m, the maximum al‐
lowed length in the flexible cable track is approx. 32 m.
A
l
= 75 m; l
seg
B
l
= 48 m; l
seg
Fig. 7-12:
Maximum allowed cable length for routing in the flexible cable track
The length l
taken from the figure is the length of the movable part of
max_schlepp
the cable connection between two motors. The RKH0700 cable can be used
for the movable part of the flexible cable track connection so that it is
replaceable and thereby easy to maintain.
Technical justification of the specified lengths: Only within the specified
lengths is it ensured that the properties of the Ethernet communication
(attenuation, crosstalk) remain in the allowed range during the service life of
the cable.
)
seg
= 11.5 m
max_schlepp
= 48 m
max_schlepp
R911335703_Edition 04 Bosch Rexroth AG
229/407
Notes on project planning
)
max_schlepp

Advertisement

Table of Contents
loading

Table of Contents