hit counter script

Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual page 237

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Peak power
Derating of Peak Power
DC 500 V
DC 565 V
Comply with KCU peak power
The sum of the electric powers of all KSM/KMS of a drive line
should not exceed the indicated value P
connection box.
P
Peak power of KSM/KMS
LN_max
P
KCU peak power
DC_max
Fig. 7-8:
KCU peak power
As the length of the hybrid cable increases, the peak power available at the
cable end is reduced.
Peak power depending on the cable length
Due to occurring voltage drops, the effective length of the cable
influences the available peak power at KSM/KMS.
Observe the following diagrams and the sections
"Peak power when accelerating" on page 224
" Peak Power when Decelerating" on page 225
Notes on project planning
of the KCU drive
DC_max
R911335703_Edition 04 Bosch Rexroth AG
223/407

Advertisement

Table of Contents
loading

Table of Contents