IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
7.1.6
Control voltage power requirement 42 V
Power components
Basic power of the component
Digital inputs/outputs
Optional safety technology S3
Optional safety technology SD
Optional master communication
output coupling TO
Optional external master
communication ES
Optional safety technology L3
Motor holding brake KSM...041
Motor holding brake KSM...061
Motor holding brake KSM...071
Motor holding brake KSM...076
Motor holding brake KMS
Control voltage power requirement
of one component
Control voltage power requirement
of multiple components of a drive
Symbol
Power
requirement [W]
P
15
Basic
P
2.5
IO
P
2.5
S3
P
2.5
SD
P
-
TO
P
-
ES
P
-
L3
P
12
Br
18
24
24
n.s.
Tab. 7-1:
Control voltage power requirement
P
= P
+ P
N3_42V
Basic
IO
P
= ΣP
total
N3_42V
line
Explanation
Component: KSM, KMS, KMV, ...
Connection point X37, X38
The power component is only available when the
digital outputs are used without an additional external
24V supply.
Safety option "Safe Motion (without SBC)"
Safety option "Safe Motion"
No additional power required
Power requirement contained in basic power of the
component P
Basic
See specification of motor holding brake of the
connected motor
+ P
+ P
S3/SD
Br
R911335703_Edition 04 Bosch Rexroth AG
219/407
Notes on project planning