hit counter script

Close Window Start; Close Window Stop - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

212 en | Schedules
Avoid programming the Open Early Begin, page 209 time that is between another window's
Open Window Start, page 210 and Open Window Stop, page 211 times.
Disabled windows have a 00:00 start time. If the entry for this parameter is 00:00, but times
are programmed for Close Window Start and Close Window Stop, the window is disabled.
To disable the window, both the hours and minutes spaces must be 00:00.
Ensure time entries use a 24-hour clock. For example, midnight = 00:00; 7:00 AM = 07:00; 2:45
PM = 14:45; 11:59 PM = 23:59.
If the window needs to activate on the same day you program it, reboot the control panel to
activate today's window.
RPS Menu Location
Schedules > Open/Close Windows > Close Early Begin
11.1.8

Close Window Start

Default: Disable
Selections: Disable, HH:MM (hours and minutes)
This parameter is one of three required to create a closing window. Enter the time that you
want the control panel to start the closing window. The window goes into effect at the
beginning of the minute.
00:00 is Midnight 23:59 is 11:59 P.M. Make entries using a 24-hour clock (for example, 7:00
AM is entered as 07:00, 2:45 PM is entered as 14:45).
To program a closing window, Close Early Begin, page 211 and Close Window Stop, page 212
must also be programmed.
A warning tone sounds and [PLEASE CLOSE NOW] displays at the keypad if the area is not
armed when the Close Window Start time comes. To temporarily silence the tone, press the
[ESC] key on the keypad. The warning tone restarts in 10 minutes if the area is not armed.
Refer to Close Early Begin, page 211 for report feature explanations.
RPS Menu Location
Schedules > Open/Close Windows > Close Window Start
11.1.9

Close Window Stop

Default: Disable
Selections: Disable, HH:MM (hours and minutes)
This parameter is one of three required to create a closing window. Enter the time that you
want the control panel to end the closing window. The window stops at the end of the minute.
00:00 is Midnight 23:59 is 11:59 P.M. Make entries using a 24-hour clock (for example, 2:45
PM is entered as 14:45).
To program a closing window, Close Early Begin and Close Window Start must also be
programmed.
If the area is not armed by the time the Close Window Stop time expires, the control panel
generates a FAIL TO CLOSE report if enabled in Fail To Close.
Closing reports generated between the Close Window Start time and Close Window Stop time
can be suppressed by setting Disable O/C in Window to Yes. Refer to Close Early Begin for
other report feature explanations.
Do not use a time of 23:59 as a window stop time unless the window continues on the next
day at 00:00. FAIL TO CLOSE reports are not sent, and the Auto Close feature does not work
for windows that stop at 23:59.
Do not program a single window to cross the midnight boundary. The window stop time must
be later than the window start time. To program a window that effectively crosses the
midnight boundary, you have to program two windows.
2017.03 | 09 | F.01U.303.998
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e

Table of Contents

Save PDF