hit counter script
Miele DA 5321 W Operating And Installation Instructions
Miele DA 5321 W Operating And Installation Instructions

Miele DA 5321 W Operating And Installation Instructions

Miele ventilation system operating and installation instructions

Advertisement

Operating and Installation
Instructions
Ventilation System
DA 5321 W
DA 5381 W
DA 5391 W
en - US, CA
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
M.-Nr. 07 260 360

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 5321 W

  • Page 1 Operating and Installation Instructions Ventilation System DA 5321 W DA 5381 W DA 5391 W en - US, CA To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 07 260 360...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the appliance Operation Turning on the fan ..........10 Selecting the power level.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is designed to vent This appliance is intended for cooking smoke and odors only. residential use only. Use the Be certain your appliance is appliance only for its intended properly installed and grounded by a purpose.
  • Page 4 Supervise its use by the elderly or certain conditions it may be possible for infirm. installation in these applications. Please contact the nearest Miele dealer or the Do not flambé or grill with an open Technical Service Department with flame beneath the hood.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS , WARNING - TO REDUCE , WARNING TO REDUCE THE RISK OF INJURY THE RISK OF A COOKTOP TO PERSONS IN THE EVENT OF A GREASE FIRE: COOKTOP GREASE FIRE, OBSERVE Never leave surface units THE FOLLOWING: unattended at high settings.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation Never connect an exhaust hood to an active chimney, dryer vent, vent flue, , WARNING or room ventilating ductwork. Seek To reduce the risk of fire only use professional advice before connecting metal ductwork. an exhaust hood vent to an existing, Any fittings, sealant, or materials inactive chimney or vent flue.
  • Page 7: Functional Description

    Functional description The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filter and directed outside. The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
  • Page 8: Guide To The Appliance

    Guide to the appliance...
  • Page 9: Grease Filter

    Guide to the appliance a Chimney extension k Grease filter button The indicator next to the grease filter b Chimney button lights when the grease filters need to be cleaned. This button is also c Canopy used: – to reset the grease filter timer after d Grease filter cleaning the grease filters (see "Cleaning and Care").
  • Page 10: Turning On The Fan

    Operation Turning on the fan Automatically switching back the Intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Press the On/Off button. ^ Turn the fan and the lights off. Selecting the power level ^ Press and hold the "Delay Shut down"...
  • Page 11 Operation If the power level indicators flash the Fan performance automatic switch back is not activated. The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this value. Level 1 operates at 40% capacity ^ To activate the automatic switch Level 2 operates at 60% capacity press the "+"...
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down Turning off the fan If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue ^ Press the On/Off button to turn the running for either 5 or 15 minutes.
  • Page 13: Turning The Lighting On/Off

    Operation Turning the lighting on/off Dimming the lighting The overhead lighting can be turned on The brightness of the lighting can be and off independently from the fan. adjusted. ^ While the lighting is turned on, press the light button. The lighting will dim until the button is released.
  • Page 14: Filter Timers

    Operation Filter timers Checking the filter timers A timer monitors the hours of fan To check the percentage of time operation. The indicator for the grease already used: filter will light after 30 hours of operation. The grease filters must then be cleaned.
  • Page 15: Reprogramming The Timers

    Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. The lit indicator shows the programmed – A time of 20 hours should be time: programmed in kitchens with 1st indicator from the left...
  • Page 16: Cleaning And Care

    Cleaning and Care Stainless steel Before cleaning or servicing the hood, disconnect it from the power Stainless steel surfaces can be cleaned supply by either removing the fuse, using a non-abrasive stainless steel unplugging it from the outlet, or cleaner. manually "tripping"...
  • Page 17: Grease Filters

    Cleaning and Care Grease filters ^ In a dishwasher: place the filter vertically in the lower basket, making The reusable metal grease filters sure that the spray arm is not remove solid particles from the vented blocked. kitchen air (grease, dust, etc). Use a hot temperature program, e.g.
  • Page 18: Changing The Light Bulbs

    Cleaning and Care Changing the light bulbs Disconnect the exhaust hood from the power supply by either shutting off the main breaker, unplugging the appliance or completely removing the fuse. When in use halogen bulbs become extremely hot, and can burn your hands.
  • Page 19: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 21 Installation Instructions...
  • Page 22: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 23: Appliance Dimensions

    Appliance dimensions 1) and 2) Installation area Wall/ceiling area respectively for vent hole and outlet installation. Vent hole 5 " (150 mm) with reducing collar 5" (125 mm).
  • Page 24 Appliance dimensions Distance between cooktop and Do not install this exhaust hood over hood (S) cooktops burning solid fuel. The installation procedure differs depending on the model and venting Provided a larger distance is not method. given by the manufacturer of the Before beginning the installation: cooktop, follow the minimum safety ^ Read all instructions.
  • Page 25: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 26 Installation accessories...
  • Page 27: Installation Accessories

    Installation accessories 3 protective shields to prevent scratches to the chimney during installation. 8 large headed screws 5 x 40 mm 2 hose clips for securing the for securing the retaining plates and the ducting. canopy. 1 reducing collar for use with 5" (S8 wall anchors included in the (125 mm) exhaust ducting.
  • Page 28: Installation Instructions

    Installation Installation instructions Dismantling ^ See the enclosed installation If the hood needs to be disassembled, instruction sheet. follow the instructions on the installation sheet in the reverse order. ^ Please read the "Important Safety Instructions" and Installation A lever is enclosed for easier removal instructions before installing this of the chimney extension.
  • Page 29: Air Extraction

    INSTRUCTIONS" to reduce the risk of prevent condensation dripping into personal injury. Follow all local building the appliance. codes when installing the hood. – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used.
  • Page 30: Condensate Trap

    Air extraction Condensate trap optional accessory – If the exhaust is ducted into an inactive flue, the air must be expelled In some cases, a condensate trap may parallel to the flow direction of the also be required to collect and flue.
  • Page 31: Electrical Connection

    Important (USA and Mexico only) licensed electrician or call Miele’s The hood comes equipped with a 4 ft Technical Service Department. See (1.2 m) power cord with a NEMA 5-15 back cover for contact information.
  • Page 32 DA 5381 W / DA 5391 W ..430 W DA 5321 W ....450 W Overhead lighting DA 5381 W / DA 5391 W .
  • Page 36 Alteration rights reserved / 0908 M.-Nr. 07 260 360 / 00 For most the updated manual see the Miele web site.

Table of Contents