Page 1
Operating and installation instructions Cooker hood DA 5330 W en - GB To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and should be recycled.
Any other usage is not supported by This appliance complies with all the manufacturer and could be relevant local and national safety dangerous. Miele cannot be held liable requirements. Inappropriate use for damage resulting from incorrect or can, however, lead to personal injury improper use or operation of the and damage to property.
Technical safety Installation, maintenance and repairs may only be carried out by a Before installation, check the cooker Miele authorised person in accordance hood for visible signs of damage. with current national and local safety Under no circumstances should you regulations.
Page 7
Warning and Safety instructions Do not connect the appliance to the Using at the same time as other mains electricity supply by a heating appliances that depend on multi-socket unit or an extension lead. the air from the room Extension leads do not guarantee the Warning - danger of toxic fumes required safety of the appliance (e.g.
Page 8
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
Warning and Safety instructions Correct use Do not use the cooker hood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the cooker hood. To avoid the danger into the appliance and hindering its of fire, do not flambé...
Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
Modes of operation The cooker hood works with . . . air extraction: . . . air recirculation: (requires a conversion kit and charcoal filters: see "Technical data") The air is drawn in, cleaned by the grease filters and directed outside. If the on-site ventilation system is not The air is drawn in and cleaned first by already fitted with non-return flaps,...
Page 13
For this to Grease filters happen, the operating hours counter Cover panels Miele DDW 53x0 needs to be activated before the appliance is used for the first time. (optional accessory)
Miele electric hob with onset controls. This module must be installed by a This cooker hood operates with two Miele service technician or suitably fans.
Operation Intensive setting The two sides of the cooker hood can When frying or cooking food with a be operated independently of one strong aroma, you may wish to select another. the Intensive setting, level IV, for a short period. To switch a fan on Automatic switch-off of the Intensive setting...
Operation Run-on option It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the The indicator lamps for fan power levels air, whether you are using air extraction I and IV will flash if the automatic or recirculation mode.
Operation To switch the hob lighting on Safety cut-out The hob lighting can be switched on Should the cooker hood be left on, the and off independently of the fan. fan will switch off automatically after 10 hours. The lighting will remain on. ^ Briefly press the lighting control to switch on the hob lighting.
Page 18
Operation ^ To do this, while the fan is switched 1 lamp = 25 % on, press and hold the grease filter 2 lamps = 50 % control until only the first of the – / + 3 lamps = 75 % indicator lamps is flashing.
Page 19
Operation Activating and altering the charcoal filter operating hours counter (in recirculation mode) ^ Press the run-on option control and The charcoal filter is needed for the grease filter control at the same recirculation mode. time. On delivery, the operating hours counter The indicator lamp for the grease filter for the charcoal filter is deactivated.
Page 20
Operation ^ Use the – / + controls to select the Reading the charcoal filter operating desired time. hours counter To check the percentage of time set already used: ^ Confirm the selection by pressing the charcoal filter control. All the indicator lamps will go out. ^ Press the On/Off control to switch the fan on.
Cleaning and care A range of Miele branded cleaning and Do not use too much water when conditioning products is available to cleaning the controls. Water could order from Miele (see back page for details) or via the internet at penetrate into the electronics and cause damage.
Cleaning and care Important for appliances with An oversaturated filter is a fire lacquered housing hazard. (special order finish) If cover panels are fitted as an optional It is very difficult to clean this type of extra, these need to be removed first. surface without causing minor marks to the surface material.
Page 23
Make sure that the spray arm can move freely. ^ Do not wash at more than 65° C. If a Miele dishwasher is being used, select the Sensor wash programme. ^ To do this, while the fan is switched ^ Use a mild dishwasher detergent.
New charcoal filters can be – they are no longer effective in purchased from your Miele dealer, absorbing kitchen odours. from the Miele Spare Parts Department or via the internet on They should, however, be replaced at www.miele.co.uk.
Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Please note that this appliance has two electrical connections, and both have to be disconnected for cleaning or maintenance work. Exercise caution when changing halogen lamps.
Appliance dimensions 1) Extraction Connection for air extraction 2 x C 150 mm, or C 125 mm with 2) Recirculation reducing collar. 3) Ventilation grille positioned at the top for recirculation 4) and 5) The shaded areas represent the wall or ceiling area for the vent cut-outs and for fitting the connection sockets.
If this cooker hood is installed above – If you want the top of the cooker a Miele Wok CS 1028 CombiSet hood to be mounted flush with the appliance, a minimum safety ceiling, make sure there is adequate distance of 760 mm must be space below it for working.
Page 29
Installation 6 protective sheets for use when fitting the towers. 2 exhaust connections for exhaust ducting C 150 mm 12 screws 5 x 40 mm and 12 x S 8 plugs for securing the wall 2 reducing collars brackets. for C 125 mm exhaust ducting The screws and plugs are 2 non-return valves designed for use in solid walls only.
Installation Dismantling Before installation, it is important to Should the appliance ever need to be read the information given on the dismantled, follow the installation following pages as well as the instructions in reverse order as "Appliance dimensions" and the described on the installation sheet.
Connection for air extraction – Where ducting is horizontal, it must Important: To avoid the danger of be laid to slope away at at least 1 cm toxic fumes, please observe the per metre. This is to ensure that Warning and Safety instructions. condensate cannot drain back into This is especially crucial when using the cooker hood.
Connection for air extraction Condensate trap (optional accessory) In addition to insulating the exhaust ducting, we recommend that two suitable condensate traps are also installed to collect and evaporate any condensate which may occur. Condensate traps are available for C 125 mm or C 150 mm ducting. When installing a condensate trap, ensure that they are positioned vertically and if possible directly above...
Connection for air extraction Silencer (optional accessory) To achieve even further reductions in noise levels, special silencers can be fitted in the ducting system..with air extraction: The silencers not only reduce noise from the fan, but also sounds from outside (e.g.
Electrical connection If these switches are not accessible All electrical work should be after installation (depending on undertaken by a suitably qualified country), an additional means of and competent person in strict disconnection must be provided for all accordance with current national poles.
Operation with Control module DSM 400 The Miele DSM 400 control module can Installation be used to combine the cooker hood with other components. As the right and left hand sides of the hood work independently of one another, two control modules are required for this.
For information on the appliance under guarantee, please contact: guarantee specific to your country – Your Miele Dealer / Chartered Agent please contact Miele. See back cover for contact details. In the U.K. your appliance is –...
Level III ....660 m Level IV Intensive Setting ..980 m Special accessory for recirculation mode: – 2 conversion kits DUW 20 – 2 Miele charcoal filters DKF 12-1...