hit counter script
Table of Contents

Advertisement

Quick Links

MIC IP ultra 7100i │ MIC IP starlight 7100i
en
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch MIC-7504-Z12WR

  • Page 1 MIC IP ultra 7100i │ MIC IP starlight 7100i User Manual...
  • Page 3: Table Of Contents

    5.16 Audio 5.17 Pixel Counter Recording Introduction to recording Storage Management 6.2.1 Device manager 6.2.2 Recording media 6.2.3 Activating and configuring storage media 6.2.4 Formatting storage media 6.2.5 Deactivating storage media Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 4 10.1.10 Full-screen display 10.1.11 Audio communication 10.1.12 Storage, CPU and network status 10.1.13 Status icons 10.1.14 IP Address of Connected Devices 10.1.15 Date and Time 10.1.16 Video Security App 10.2 Playback 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 5: Mic Ip Ultra 7100I │ Mic Ip Starlight 7100I Table Of Contents | En

    Using Intelligent Tracking 11.2 Recommended Use of Your MIC Camera 11.3 Uploading a User Logo 11.4 Two-line and Three-line Camera Titles 11.5 Azimuth, Elevation, and Compass Directions Troubleshooting Status Codes AUX Commands Support Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 6: Introduction

    100 connections via Bosch Video Client or BVMS. Project Assistant In order to use this device with the Project Assistant app by Bosch, you must download the app from the Bosch Download Store, from Google Play, or from the Apple Store.
  • Page 7: Password Protection In Camera

    MIC IP ultra 7100i │ MIC IP starlight 7100i Introduction | en – From Apple Store (itunes.apple.com), search for Bosch Project Assistant. Select the app from the list. Click the appropriate button to download and install the app. Password protection in camera The device is password-protected.
  • Page 8: System Overview

    Click this icon to configure the device. Dashboard Click this icon to see detailed system information. Links Click this icon to navigate to the Bosch download store. Click this icon to get context-sensitive help for the page you are browsing. Live page The Live page is used to display the live video stream and control the unit.
  • Page 9: Dashboard

    The Dashboard page is used to display detailed information about the device. The Dashboard is only visible in the application bar if the Show 'Dashboard' option is enabled by a service-level user in the Configuration -> Web Interface -> Appearance page. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 10: General

    A check mark in this check box indicates that at least one certificate is loaded onto the camera. If no certificates are loaded, then “No certificate installed” appears to the right of the text. The Escrypt certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: –...
  • Page 11: Date/Time

    Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording. Device time zone Select the time zone in which the system is located. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 12: Display Stamping

    (Position (XY)). In the Position (XY) fields, enter the values for the desired position. Optionally, tick the Underlay with full-width black bar box to place a black bar beneath the time stamp. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 13 Select On to momentarily display camera response information, such as Digital Zoom, Iris open/close, and Focus near/far overlays in the image. Select Off to display no information. Select the desired option from the list. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 14 If you want to add a digital signature to the transmitted video images to ensure their integrity, select one of the cryptographic algorithms for this signature. Signature interval [s] For certain Video authentication modes, enter the interval (in seconds) between insertions of the digital signature. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 15: T 28181

    Enter the ID of the device. Device port Enter the number of the device port. The default is 5060. Password Enter the appropriate password. Alarm device ID Enter the ID of the alarm device. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 16: Web Interface

    Select this check box to show overlay icons on the live video image. Show VCA items Shows alarm fields, lines and routes configured for the video analytics in the following colors: 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 17: Live Functions

    80 kbps per connection in each direction. Auto logout time [min] Set a time frame (in minutes) for the automatic logout. Default value is 0 (no automatic logout). Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 18 LIVE page. If necessary, click Browse to find a suitable directory. Video file format Select a file format for the live page display. The MP4 format does not include metadata. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 19: Camera

    Do not remove power to the unit during a factory default or a firmware update. Wait at least two minutes for the default process to complete. If the unit appears to be "frozen" after two minutes, then reboot the unit. Refer to Troubleshooting, page 76 for more details. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 20: Positioning

    Select the Global check box to use the global, overall calibration for all AUTODOME and MIC cameras. Alternatively, clear the Global check box to obtain a local calibration and overwrite the global calibration for the selected profile. To do this, select the VCA profile before. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 21 The angle on ground represents an angle lying on the horizontal ground plane, such as the corner of a carpet or parking bay markings. Adjust the calibration elements to the situation: Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 22 The orientation of the camera in a counter-clockwise angle starting with 0° in the east (WGS 84) or on the X-axis (Cartesian). If the camera is directed towards the north (WGS 84) or the Y-axis (Cartesian), the azimuth is 90°. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 23: Scene Mode

    – Custom mode #1 If necessary, select a custom mode. – Custom mode #2 If necessary, select a second custom mode. Mode ID The name of the selected mode is displayed. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 24: Picture Settings

    Use the slide to select the desired number for fixed gain. The default is 2. Maximum gain level To set the Maximum gain level, select Low, Medium or High from the drop-down box. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 25 Night mode priority Select the option to which the camera should give priority while in night mode: – Motion – Color (default) Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 26: Enhance

    Intelligent Defog With the Intelligent Defog mode feature, visibility can be improved significantly when viewing foggy or other low-contrast scenes. Select Auto to activate the Intelligent Defog feature automatically as needed. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 27: Scene Mode Scheduler

    Change the profiles only once you are fully familiar with all the configuration options. Note: In the default setting, Stream 1 is transmitted for alarm connections and automatic connections. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 28 (Minimum bit rate). Select the necessary bit rate optimization setting: – Off: bit rate optimization is disabled – Maximum quality – High quality – Medium – Low bit rate – Minimum bit rate 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 29 A higher quantization value results in low image quality and lower network load. Typical QP values are between 18 and 30. The basic setting Auto automatically adjusts the quality to the settings for the P-frame video quality. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 30: Encoder Streams

    Profile 2 HD Balanced For an HD image, the video bit rate and frame quality are adjusted to a median profile for everyday use. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 31: Encoder Statistics

    Important parts of the scene (identified as objects in the GUI) are encoded at high resolution and therefore have an enhanced encoding quality. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 32: Privacy Masks

    The default mask template has four corners. You can add or delete corners as needed: – To add a corner, double-click the side of the mask where you want to add the corner. – To delete a corner, double-click the corner to remove. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 33: Lens Settings

    Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the day. Night near limit [m] Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the night. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 34: Ptz Settings

    Select the appropriate number of sectors (for example, 4, 6, 12, or 16). Note: The number that you select in this field determines the number of sectors that appear in the Sectors page (below). 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 35 Sets the upper tilt limit of the camera. Use the preview window to move the camera to the tilt limit and click the button. Pan limit left Set the appropriate pan limit on the left. Pan limit right Set the appropriate pan limit on the right. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 36: Pre-Positions And Tours

    SW, W, NW) heading in which the camera is pointing. Notice! The compass feature is not compatible with Bosch’s Intelligent Tracking feature. If Intelligent Tracking is activated, the camera automatically disables the display of the compass heading. Once Intelligent Tracking is deactivated, the camera returns the compass heading to the display.
  • Page 37: Pre-Position Settings

    Custom pre-position tour Select the dwell time in seconds or minutes for the Custom pre-position tour. 5.11 Pre-position settings Pre-position Select the number of the pre-position for which to save specific settings. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 38: Pre-Position Mapping

    Select the degree of intensity of the White light. 5.12 Pre-position mapping Pre-position mapping allows you to map a function to a pre-position action. This feature works for Bosch protocols and for non-Bosch protocols. Action Select the appropriate action: Show or Set. Pre-position Enter the number of the pre-position to map.
  • Page 39: Sectors

    Fast address This parameter allows the appropriate camera to be operated via the numerical address in the control system. Enter a number between 0000 and 9999, inclusive, to identify the camera. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 40: Illuminator

    (after which the camera will stop the wiper automatically). – Intermittent: Wipes twice, then stops. Every 15 seconds, this cycle repeats until users select another option in this field. – One shot: Wipes five times, then turns off. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 41: Audio

    To change the shape of a zone, place the cursor over the edge of the zone, hold down the mouse button and drag the edge of the zone to the required position. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 42: Recording

    A iSCSI target storage device can only be associated with one user. If a target is being used by another user, ensure that the current user no longer needs the target before decoupling that user. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 43: Formatting Storage Media

    You can specify whether, in addition to video data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 44: Maximum Retention Time

    Select the Virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example. Maximum Retention Time Recordings are overwritten when the retention time entered here has expired. Enter the required retention time in days for each recording track. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 45: Recording Scheduler

    You can stop the recording activity at any time and modify the settings. Click the Start button to activate the recording scheduler. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 46: Recording Status

    Select the target account for JPEG posting. Face detection When face recognition is available, selected images of the face can be sent to a target account. Target Select the target account for JPEG posting. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 47: Alarm

    Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission parameter here and on Network Access. Stream Select the number of the stream from the drop-down list. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 48 The following field may or may not appear, depending on your camera: Audio Select On to activate audio alarms. The following field may or may not appear, depending on your camera: 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 49: Video Content Analysis (Vca)

    (and to switch analysis types), or click Cancel. Alarm status The alarm status is displayed here for information purposes. This means you can check the effects of your settings immediately. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 50: Virtual Masks

    2. Select the mask with your mouse. Move the mouse to position the mask over the area of the view that you want to mask, and then click “Set.” The text “VM Configuration active!” appears in the View Control window. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 51: Audio Alarm

    Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered. Otherwise leave the box blank (0.0.0.0). SMTP port Select the appropriate SMTP port. SMTP user name Enter a registered user name for the chosen mailserver here. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 52: Alarm Task Editor

    Click Examples under the Alarm Task Editor field to see some script examples. A new window opens. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 53: Alarm Rules

    19 is set to [camera name] - IO“ (for a camera connected to MIC-ALM-WAS-24) Click the checkbox Enabled to activate the alarm. Click Set to save. The camera’s system activates the alarm rules. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 54: Network

    If the device is used behind a firewall, TCP (HTTP port) should be selected as the transmission protocol. For use in a local network, choose UDP. Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 55 In UDP mode, comply with the MTU value set below. Network MTU [Byte] Specify a maximum value in bytes for the package size (including IP header) to optimize data transmission. Click Set to apply the changes. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 56: Dyndns

    This field identifies any cloud-based services with which the camera communicates. – If you have registered the device on a cloud-based service such as Bosch Remote Portal, then this field identifies this fact (“Registered on Bosch Remote Portal”). Note: The button (Connect to Bosch Remote Portal) to connect to the device with that service is active.
  • Page 57 MIC IP ultra 7100i │ MIC IP starlight 7100i Network | en Note: The button (Connect to Bosch Remote Portal) to connect to the device with that service is not active. Stratocast Enter the Stratocast Registration code to connect with the Genetec’s Stratocast cloud.
  • Page 58: Network Management

    (Multi-unicast), or it is sent as a single stream to the network, where it is simultaneously distributed to multiple receivers in a defined group (Multicast). 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 59: Accounts

    Account name Enter an account name to be shown as the target name. IP address Enter the IP address of the server on which you wish to save the JPEG images. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 60: Ipv4 Filter

    IP Address 1 / 2 Enter the IPv4 address that you want to allow or block Mask 1 / 2 Enter the subnet mask for the appropriate IPv4 address. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 61: Service

    Licenses This window is for the activation of additional functions by entering activation codes. An overview of installed licenses is shown. The installation code of the unit is also displayed here. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 62: Certificates

    This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Select the text on this page with a mouse and copy it so that it can be pasted into an e-mail if required. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 63: Operation Via The Browser

    OSD displays the Camera number (title), the Pre-position number, and the Pre- position number stored. Below the list of pre-positions/scenes is a drop-down list showing the stored pre-positions/ scenes. Select the appropriate pre-position (1 through 6). Click to store the pre-position. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 64 Note: If the pre-position is already stored, a dialog box displays the message, “Overwrite current pre-position?” Click OK to overwrite, or click Cancel to cancel the operation. Click to display the selected pre-position in the video image. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 65: Aux Control

    Click this button again to turn off the IR light. White light Click this button to turn on the White light of the illuminator accessory (if available on your camera). Click this button again to turn off the White light. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 66: Recording Status

    – if the CPU load is too big, change the VCA settings, – if the network load is too big, change the encoder profile to reduce bitrate. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 67: Status Icons

    The unlabeled date and time ticker appears above the row of icons (including ) that is below the lower-left corner of the live video image. 10.1.16 Video Security App Start Video Security app To start the Video Security app, click Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 68: Playback

    Select the playback (forward or backward) speed using the speed regulator – Step forward or backward frame-by-frame when paused (small arrows) 10.3 Dashboard The Dashboard page shows information on 4 topics: – Device status – Recording status 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 69 You can also download a .JSON file with information about the device: At the bottom of the page, locate the Export button Click the Export button Select a location in your hard drive to store the file Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 70: Using Your Mic Camera

    If the Intelligent Tracking feature is set to Auto or Click, the live video image displays an eye icon with a symbol that conveys the state of Intelligent Tracking activity: Graphic Description Explanation 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 71 The camera will restart tracking if a target starts moving in the same area where the initial target stopped moving or if the camera detects an object moving along the last known trajectory. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 72: Recommended Use Of Your Mic Camera

    Note: Tour B is now intended for use with the 'IVA while moving' functions. Preset Tours For scenarios that require the camera to be in continuous motion for most of the day, Bosch recommends that you set the camera in Preset Tour mode, moving between a desired set of presets.
  • Page 73: Uploading A User Logo

    Select one of the following options. Users can toggle between the two options. – Display two (2) lines of text at the top of the video. Use the command AUX ON-75-ENTER. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 74 LOOKING will always appear in English and will be at a fixed location on the OSD. – The X or XX designates the compass direction that updates automatically as the camera pans. A identifies “North,” “South,” “East,” or West.” AA identifies “Northeast,” “Northwest,” “Southeast,” or “Southwest.” 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 75: Azimuth, Elevation, And Compass Directions

    Azimuth Zero point. Notice! Bosch recommends that only the installer calibrate the Azimuth Zero point. A recalibration to the Azimuth Zero point may cause inaccurate compass headings. Set the Azimuth Zero point: Determine the North compass heading, then move the camera to that position.
  • Page 76: Troubleshooting

    Your camera has an improper network connection. intermittently Test your camera with another power supply. Check the Bosch website for a software update that might address the issue. Nothing appears on the screen. Are the power cord and line connection between the camera and monitor made properly? The image on the screen is dim.
  • Page 77 (especially on the yoke arms). – If there is obvious and severe damage, stop using the camera and contact your Bosch Service Center for assistance. – If no damage is evident, complete one of the following steps: a) Cycle the power on the camera.
  • Page 78 MIC IP ultra 7100i │ MIC IP starlight 7100i Configuration or video management The model ID may be corrupt. software identifies the unit as Complete the steps in the section Rebooting the unit. “Videojet Generic”. 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 79: Status Codes

    21 VAC and 30 VAC. Camera may be operating in an 1. Verify that the ambient temperature is not environment where ambient below -40 °C (-40 °F). temperature is below the specification of the camera. Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 80 2. Verify the integrity/tightness of the external fasteners. Tighten where necessary. 3. If obvious damage is present, stop using the camera and contact the nearest Bosch Security Systems Service Center. 4. If no damage is evident, power the camera off and then on, and then evaluate operational performance.
  • Page 81 Configure the washer pre-position. If without washer pre-position being necessary, refer to the subchapter “Using the stored. Wiper/Washer (Bosch AUX/Pre-position Commands)” in the User Manual for details on configuring washer functions. Attempt was made to move to a pre- 1. Select/configure a different pre-position position that is mapped to an number for the desired location.
  • Page 82 (and the window defrosters, for MIC IP fusion 9000i). If the log notes heater or defroster failure, contact the nearest Bosch Security Systems Service Center. 3. If operation is obstructed because of...
  • Page 83 (Configuration > Camera > Installer Menu >Reboot device). If this action does not resolve the problem, contact the nearest Bosch Security Systems Service Center. The Service Center may request information from the diagnostics log of the camera (accessible from the Service menu).
  • Page 84: Aux Commands

    Sector Blanking On/Off Privacy Masking On/Off Proportional Speed On/- Recalibrate Azimuth Compass On/Off Azimuth/Elevation Display On/Off Compass Points Display On/Off Record Tour A On/Off Record Tour B On/Off Wiper On/Off (Continuous) 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 85 Function Command Description On/Off IR mode AUX ON sets IR to Auto. AUX OFF sets IR to OFF. Available for only. On/Off Night mode IR Filter In/Out On/Off White light illumination Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 86: Support

    – Troubleshooting – Repair & Exchange – Product Security Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses, video tutorials and documents: https://www.boschsecurity.com/xc/en/support/training/ 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 87 MIC IP ultra 7100i │ MIC IP starlight 7100i Support | Bosch Security Systems User Manual 2020-07 | 1.2 |...
  • Page 88 | Support MIC IP ultra 7100i │ MIC IP starlight 7100i 2020-07 | 1.2 | User Manual Bosch Security Systems...
  • Page 90 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2020...

This manual is also suitable for:

Mic ip starlight 7100iMic ip ultra 7100iMic-7504-z12brMic-7504-z12gr

Table of Contents