486/653
Diagnosis
13.5.3 Error Reset by Digital Input
The error reset input can be defined with one digital input. This function works
in the same manner as the panel error reset function does, which allows remote
error reset. 'Error reset signal' is edge sensitive.
Code
Name
E1.00
X1 input
E1.01
X2 input
E1.02
X3 input
E1.03
X4 input
E1.04
X5 input
H8.00
EX1 input
H8.01
EX2 input
H8.02
EX3 input
H8.03
EX4 input
H8.04
EX5 input
Set the respective parameter of any digital input as '34: Error reset signal'. For
wiring diagram, please refer to
75.
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Setting range
34: Error reset
chapter "Digital input NPN / PNP wiring" on page
Series
Default
Min.
Attri.
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop
0
–
Stop