74/135
Bosch Rexroth AG | Electric Drives
PC CPU Configuration -45
5.5.3
IDE Port
and Controls
The IDE port of the BTV 20.4 is a vacant port (primary IDE port), to which a
further hard disk or a CD-ROM drive can be connected.
The device connected is to be selected in the BIOS. The Primary Master is set
to "Automatic detection" and the Primary Slave is disabled in the delivery status.
The maximum allowed cable length for IDE cables is 50 cm!
Fig.5-27:
Pin assignment