GE Multilin F650 Instruction Manual (534 pages)
Brand:
GE
| Category:
Controller
| Size: 7.21 MB
Table of Contents
Table of Contents
2
Getting Started
10
Cautions and Warnings
10
Communication Boards Withdrawal/Insertion
10
Front View of F650 Units
10
Important Procedures
10
Module Withdrawal/Insertion
11
Magnetic Module Terminals
12
Rear View of F650 Unit
12
Identification Label (A4455P6)
13
Inspection Checklist
13
Location of Grounding Screw
15
Safety Instructions
15
F650 Concept Block Diagram
16
Hardware Architecture
16
Overview
16
Introduction to 650 Family of Relays
16
Software Architecture
17
Communications Architecture
17
Rear Serial Communications Board 1
17
Communications Architecture (B6816F1)
18
Overview
18
Rear Ethernet Communications Board 2
18
System Requirements
19
Installation
19
Enervista 650 Setup Software
19
Add Product Window
20
Web Upgrade Window
20
Enervista F650 Setup Installation
21
Language Window
22
Select Program Folder
22
Configuring an Ethernet Connection
23
Connecting with the Unit
23
Enervista Launchpad
23
Communications
24
Configuring an RS232 Connection
24
Communications
25
Relay - PC Connection for RS232 Front Port
25
RS485 Connection for F650 Units
26
F650 Overview
28
Functional Block Diagram
28
Product Description
28
ANSI Device Numbers and Functions
29
Summary
29
Ordering Code
31
Product Description
31
Ordering Code for CIO Module
32
Technical Specifications
33
Protection Units
33
Phase Time Overcurrent with Voltage Restraint (51PH/51PL)
33
Ground Time Overcurrent (51G)
33
Neutral Time Overcurrent (51N)
34
Sensitive Ground Time Overcurrent (51SG)
34
Phase and Ground Instantaneous Overcurrent (50PH/50PL/50G)
35
Neutral Instantaneous Overcurrent (50N)
35
Sensitive Ground Instantaneous Overcurrent (50SG)
36
Isolated Ground Instantaneous Overcurrent (50IG)
36
Negative Sequence (46)
36
Phase Directional (67P)
37
Ground Directional (67G)
37
Neutral Directional (67N)
37
Sensitive Ground Directional (67SG)
38
Thermal Model (49)
38
Phase Overvoltage (59P)
38
Phase Undervoltage (27P)
39
Neutral Overvoltage (59NH/59NL)
39
Negative Sequence Overvoltage (47)
39
Auxiliary Overvoltage (59X)
39
Auxiliary Undervoltage (27X)
40
Underfrequency (81U)
40
Overfrequency (81O)
40
Forward Power (32FP)
41
Sensitive Directional Power (32)
41
Broken Conductor (I2/I1)
41
Control
42
Locked Rotor (48)
42
Autoreclose (79)
42
Synchrocheck (25)
42
Fuse Failure
43
Breaker Failure (50BF)
43
Breaker Settings
43
Breaker Maintenance
43
Monitoring
44
Oscillography
44
Fault Locator
44
Snapshot Events
45
Control Events
45
Demand
45
Data Logger
45
PLC Logic
46
Flexcurves
46
User -Programable Elements
46
Metering
47
User-Programmable Front Keys
47
Current
47
Watt-Hours (Positive and Negative)
47
Inputs
48
AC Current Inputs
48
AC Voltage Inputs
48
Digital Inputs
48
Real Time Clock
49
Outputs
49
IR/G-B Input
49
Control Power Supply
50
Communications
50
Outputs
50
Environmental Characteristics
51
Packaging and Weight
51
Type Tests
52
Approvals
52
Wiring Diagram for Models with Option 1
53
External Connections
53
Wiring Diagram for Models with Option 2
54
Hardware
56
Communications
56
Communications Module
57
Module Description
56
Block Diagram
56
Mechanical Description
58
Mounting
58
Panel Mounting
58
Drilling Dimensions Diagram
59
Side View
59
Front View
59
Panel Mounting Cutout
59
Rear Description
60
Dimensions of the 19 Racks 6U High for Two Relays
60
Connectors Location
61
Communications Media Selector Guide
62
Detail of Insertion/Extraction of Communication Modules
63
Rear Terminals Location
64
External Connections
65
Digital Inputs with Trip Circuit Supervision
65
Wiring
65
Cable/Fiber Ethernet Board
66
Fiber/Cable Selection
66
Optic Features
67
Optic Features
68
Transceiver Optical Power Budget Versus Link Length
69
Human Interfaces
70
Enervista 650 Setup Software Interface
70
Overview
70
Main Screen
71
Starting Communication
72
Communication Parameters Menu
72
Communication Troubleshooting Screen
75
File Management
77
Off Line Mode Without Connection to the Relay
77
Types of Files Generated by Enervista 650 Setup Software Operation Mode Off-Line
78
On Line Mode Connected to the Relay
80
On Line Mode File Management
80
ENERVISTA 650 Setup Menus Structure
82
General Overview of File Menu
83
Open, Save as and Close
84
Open File Menu
84
Config File Converter
85
Config File Converter Menu
85
Properties
85
File Properties Menu
85
Print Setup
86
Print Preview
86
Print
86
Print to File (XLS)
86
Product Setup
87
General Overview of Setpoint Menu in Enervista 650 Setup
87
General Overview of Product Setup Menu
87
Settings Menu Overview
87
Communication Settings
88
System Setup
88
Protection Elements
89
Different Protection Elements Included
90
Control Elements
91
Input/Outputs
92
Relay Configuration
93
Remote Devices
93
HMI Configuration
94
Logic Configuration
95
Clock
96
General Overview of Actual Values Main Menu
96
Front Panel
96
Status
96
General Overview of Status Menu
97
Different Control Actual Values Included in the Control Elements Menu
97
Records
99
Remote Inputs
99
Operations Menu Overview
100
Communication Menu Overview
100
Security Menu Overview
101
View Menu Overview
101
Help Menu Overview
101
Display
102
Text Main Screen
102
Human Machine Interface (Hmi)
102
Front Led Indicators
103
Pushbuttons
103
Keypad and Shuttle Key
103
Command Push Button
104
Front Port and Cover Sealing System
104
Detail of Front Port and Cover Sealing System
104
Text Menus
105
Navigation in Text Menu
105
Text Menu Hierarchy
106
Remote Outputs
108
Snapshot Events Navigation in HMI
110
Fault Report
111
Fault Report Navigation in HMI
112
View Settings
113
Change Settings
117
Change Settings Procedure in HMI
117
Date & Time
118
Change Date and Time Procedure in HMI
118
Commands
119
Commands in HMI
119
Passwords
120
Password Range
120
Entering the Password (Login PWD)
121
Logging out (Logout PWD)
121
Changing the Password (Change PWD Commands)
121
Password Recovery (Forgot Password)
121
Select Main Screen
122
Default Logotype Screen
122
Default Metering Screen
122
Select Language
123
Language Selection in HMI
123
Graphic Display
124
One-Line Diagram
124
Metering Screen
125
All Events Screen
126
Snapshot Events Detail Screen
127
New Events Screen
128
Alarms Panel
129
Alarms Panel in HMI
129
Input/Output Monitoring Screen
130
Inputs/Outputs General Screen
130
Input/Output Viewing Screen
131
Web Server Main Screen
133
Web Server 4.3.1 Home
133
Snapshot Events
134
Control Events
134
Control Events Screen
135
Alarms
136
Oscillography Screen
137
GE-OSC Launch Screen
137
Fault Report
138
Data Logger
139
Metering
140
Setpoints Main Menu
142
Overview
142
Communication Setpoints
144
Serial Ports
144
Network (Ethernet)
144
Modbus Protocol
144
Product Setup
144
DNP3 Slave
145
DNP Protocol Setpoints
145
IEC 60870-5-104 Protocol Setpoints
146
Modbus User Map Setpoints
146
Fault Report Setpoints
147
Fault Report States
147
Fault Report Retrieval
148
Oscillography Overview
148
Oscillography Setpoints
149
Oscillography States
150
Oscillography Files Retrieval
151
Data Logger Setpoints
151
Data Logger Associated States
152
Data Logger States
152
Data Logger Files Format and Retrieval
152
Metering Values and Setpoints for the Demand
153
Primary Demand Values
153
Demand Setpoints
153
Demand Calculation Methods
154
Thermal Exponential
154
Rolling Demand
155
Block Interval
155
Response to the Different Demand Methods
156
Demand Function Measures and States
157
Demand Associated Values
158
General Setpoints
159
System Setup
159
Flex Curves
160
Breaker
161
Flexcurves Edition
161
Breaker Setpoints
162
Breaker Status
163
Breaker Maintenance Status
164
Switchgear Setpoints
164
Change of Setpoint Tables in F650 Units
165
Protection Elements
165
Single Setpoint Group
166
Three Setpoint Groups
166
Distribution of Protection Elements
167
Setpoint Group Setpoints
167
Table Change Signals Configuration Example
168
IEEE Curves
169
Inverse Time Curves Characteristics
169
Constants for IEEE Curves
170
Tripping Time in Seconds for IEEE Curves
170
Constants for IEC Curves
171
IEC Curves
171
Tripping Time in Seconds for IEC Curves
172
Constants for IAC Curves
173
IAC Curves
173
Tripping Times in Seconds for IAC Curves
174
ANSI Curves
175
Constants for ANSI Curves
175
Tripping Times in Seconds for ANSI Curves
176
Definite Time Curves
177
I2T Curves
177
Rectifier Curves
177
Tripping Time in Seconds for I2T Curves
177
User Curve Characteristics
178
User Curves - Flexcurves A/B/C/D
178
Phase Time Delayed Overcurrent Units - Phase TOC (51PH/51PL)
179
Voltage Restraint Characteristic
179
51PH/51PL Unit Setpoints
180
TOC Unit Logic Scheme
181
50PH/50PL Unit Setpoints
182
Phase Instantaneous Overcurrent Unit-Phase IOC (50PH/50PL)
182
Phase IOC Units Logic Scheme
183
67P Unit Setpoints
184
Phase Directional Unit (67P)
184
Block and Operation Signals for the Phase Directional Element
185
Directional Unit Block Configuration by Input
186
Operation and Polarization Magnitudes for Directional Units
186
Overcurrent Units Block Configuration by the Directional Unit
186
Polarization Diagram
187
Directional Unit Logic Scheme
188
49 Unit Setpoints
189
Thermal Model Unit (49)
189
51N Unit Setpoints
190
Neutral Instantaneous Overcurrent Unit (50N)
190
Neutral Time Delayed Overcurrent Unit (51N)
190
Logic Scheme for Neutral IOC Unit
191
67N Unit Setpoints
192
Neutral Directional Unit (67N)
192
Voltage Polarization Operation Principles
193
Voltage Polarization
194
Current Polarization Operation Principles
195
Output Signals Management According to the Polarization Type Setpoint
195
Quantities
196
51G Unit Setpoints
197
Ground Current
197
Ground Instantaneous Overcurrent Unit (50G)
197
Ground Time Delayed Overcurrent Unit (51G)
197
67G Unit Setpoints
198
Ground Directional Unit (67G)
198
Used Magnitudes According to the Polarization Setpoint
198
Sensitive Ground Current
200
Instantaneous Overcurrent Unit for Ungrounded Systems (50IG)
201
Operation Characteristic for Unit 50IG
201
Operation Principles
202
Sensitive Ground Directional Unit (67SG)
202
Sensitive Ground Current
203
Negative Sequence Current
204
Negative Sequence Overcurrent Unit (46P)
204
Voltage Elements
205
Phase Undervoltage Unit (27P)
206
Phase Overvoltage Unit (59P)
207
Neutral Overvoltage Unit (High Level and Low Level)
208
Auxiliary Overvoltage Unit (59X)
209
Auxiliary Undervoltage Unit (27X)
209
Negative Sequence Overvoltage Unit (47)
209
Forward Power Characteristic
210
Forward Power Unit (32FP)
210
Directional Power Unit (32)
212
Directional Power Element Sample Applications
213
Setpoint Group
218
Control Elements
218
Overfrequency Unit (81O)
219
Underfrequency Unit (81U)
219
Synchronism Check Unit - Synchrocheck (25)
220
Application
221
Voltage Correspondence Unit 25
221
Voltage Inputs
221
Unit Setpoints
222
Synchrocheck Internal States
223
Synchrocheck States
223
Algorithm
224
Synchronism Conditions
225
Frequency Slip
226
Phase Angle Difference
226
Voltage Angle Difference
226
Anticipative Algorithm
227
High Slip Closing Permission Signal
227
79 Unit Setpoints
228
Autoreclose (79)
228
Main Autoreclose Setpoints
228
Advertisement
GE Multilin F650 Instruction Manual (801 pages)
Digital Bay Controller
Brand:
GE
| Category:
Controller
| Size: 17.33 MB
Table of Contents
Table of Contents
2
1 Getting Started
10
Important Procedures
10
Cautions and Warnings
10
Inspection Checklist
13
Safety Instructions
15
Overview
17
Introduction to 650 Family of Relays
17
Hardware Architecture
17
Software Architecture
19
Communications Architecture
19
Enervista 650 Setup Software
21
System Requirements
21
Installation
21
Connecting Enervista 650 Setup with F650
25
Hardware
27
Mounting & Wiring
27
Communications
27
Faceplate Display
28
Maintenance
28
2 Product Description
30
Overview
30
F650 Overview
30
Ansi Device Numbers and Functions
31
Other Device Functions
32
Ordering Code
33
Technical Specifications
35
Protection Elements
35
Control
45
Monitoring
49
User-Programmable Elements
51
Metering
52
Real Time Clock
55
Outputs
55
Control Power Supply
56
Communications
56
Optic Features
58
Environmental Characteristics
59
Packaging and Weight
59
Type Tests
59
Approvals
59
External Connections
60
3 Hardware
62
Module Description
62
Power Supply
63
Mechanical Description
64
Mounting
64
Rear Description
67
Wiring
71
External Connections
71
Digital Inputs with Trip Circuit Supervision
71
Cable/Fiber Ethernet Board
72
4 Human Interfaces
74
Introduction
74
Values
74
Enervista 650 Setup Software Overview
74
Main Screen
76
Communication Menu
77
File Management
79
Enervista 650 Setup Menu Structure
83
File Menu Overview
84
Setpoint Menu Overview
89
Actual Values Menu Overview
98
Operations Menu Overview
101
Communication Menu Overview
102
Security Menu Overview
105
View Menu Overview
105
Help Menu Overview
105
Human Machine Interface (Hmi)
106
Display
107
Front Led Indicators
108
Pushbuttons
108
Front Port and Cover Sealing System
110
Text Menus
111
Graphic Display
130
Web Server 4.3.1 Home
139
Snapshot Events
140
Control Events
141
Alarms
142
Oscillography
143
Fault Report
144
Data Logger
145
Metering
146
5 Settings
148
Overview
148
Setting Main Menu
148
Product Setup
150
Communication Settings
150
Modbus User Map
154
Fault Report
155
Oscillography
157
Oscillography
158
Data Logger
160
Demand IX
166
System Setup
168
General Settings
168
Flex Curves
172
Breaker
174
Switchgear
176
Time Settings
176
Protection Elements
178
Change of Setting Tables in F650 Elements
178
Inverse Time Curves Characteristics
182
Phase Current
192
Neutral Current
206
Ground Current
209
Sensitive Ground Current
212
Negative Sequence Current
217
Voltage Elements
217
Setting Group
233
Underfrequency Element (81U)
234
Overfrequency Element (81O)
235
Synchronism Check Element - Synchrocheck (25)
236
Autoreclose (79)
245
Breaker Failure Element (50Bf)
251
Vt Fuse Failure Element (Vtff)
254
Broken Conductor
255
Locked Rotor
256
Pulse Counters
257
Analog Comparators
259
Frequency Rate of Change
260
Load Encroachment
262
Input/Output Placement
264
Control Settings for Inputs/Outputs
265
Inputs
267
Outputs
269
Circuit Supervision and Contact Seal-In Circuits
271
Analog Boards Specific Settings
281
Virtual Outputs
282
Force Io–Input Testing
284
Outputs
285
Leds
286
Operations
287
Protection Elements
291
Switchgear
295
Hmi (Human-Machine Interface)
297
Enervista 650Pc Hmi Improvements
301
Introduction
302
Theory of Operation
303
Main Menu
306
Configuration Generation
307
Generation of Libraries
308
Example of Application
309
Leds
324
Operation Bits
325
Protection
326
Power
332
Control Elements
333
Protection Summary
340
Snapshot Events Summary
343
Modbus User Map
345
Calibration
346
System Info
347
Record Status
347
Metering
351
Primary Values
351
Secondary Values
354
Frequency
357
Inputs / Outputs
358
Contact Output Status
359
Contact Output Operates
359
Contact Output Resets
360
I/O Board Status
361
Remote Outputs
362
Remote Inputs
363
Analog Inputs
364
Records
365
Event Recorder
365
Waveform Capture
367
Fault Report
368
Data Logger
369
7 Iec 61850 Protocol
370
Iec61850 Generic Substation State Event (Gsse)
370
Remote Devices
370
Remote Inputs
372
Remote Outputs
373
Iec 61850 Profile for F650
375
Overview
375
Communication Profiles
377
Tcp Connection Timing
377
Mms Protocol
377
Peer-To-Peer Communication
377
File Services
377
Iec 61850 Conformance Statements
378
Iec 61850 Configurator
429
Overview
429
Iec 61850 Configurator Tool
429
GE Multilin F650 User Manual (298 pages)
Grid Solutions Digital Bay Controller
Brand:
GE
| Category:
Controller
| Size: 8.18 MB
Table of Contents
Table of Contents
3
1 Getting Started
9
Important Procedures
9
Cautions and Warnings
9
General Cautions and Warnings
10
Communication Board Withdrawal/Insertion
11
Magnetic Module Terminals
12
Inspection Checklist
13
Safety Instructions
15
General Safety Instructions
16
Warning Symbols
17
Overview
18
Introduction to the 650 Family of Relays
18
Hardware Architecture
18
F650 Basic Design
18
F650 Signal Type
19
Communications Architecture
19
Enervista 650 Setup Software
22
System Requirements
22
Installation
22
Connecting Enervista 650 Setup to the F650
26
Configuring an Ethernet Connection
26
Configuring the RS232 Connection
26
Hardware
27
Mounting & Wiring
27
Communications
27
Faceplate Display
28
Maintenance
29
General Maintenance
29
In-Service Maintenance
29
Out-Of-Service Maintenance
29
Unscheduled Maintenance
29
Storage
29
Repairs
30
Disposal
30
2 Product Description
31
F650 Overview
31
ANSI Device Numbers and Functions
33
Other Device Functions
34
Order Codes
35
CIO Modules
37
Technical Specifications
38
Protection
38
Control
46
Monitoring
49
User-Programmable
51
Metering
52
Inputs
52
Real Time Clock
54
Outputs
54
Control Power Supply
54
Communications
55
Optical
57
Environmental
58
Packaging and Weight
58
Type Tests
58
Approvals
59
External Connections
60
3 Interfaces, Settings & Actual Values
63
Enervista 650 Setup Software
63
Introduction
63
Gek-113000-Af F650 Digital Bay Controller
63
Firmware Upgrades
64
One Line Diagrams
64
Viewing Actual Values
64
Viewing Triggered Events
64
Main Screen
65
Connect to the Relay
66
Computer Settings
67
Communication Control
67
Communication Optimization
67
File Management Menu
68
Offline Mode
68
Online Mode
70
Enervista 650 Setup Menu
72
File Menu
73
New, Open, Save, Save As, and Close
74
Configuration File Converter
75
Properties
77
Print Options
77
Compare to Settings File
78
PLC Checksum Calculation
78
Setting Checksum Calculation
79
Setpoint Menu
79
Product Setup Menu
80
Communication Settings Menu
80
System Setup Menu
81
Breaker Menu
81
Protection Elements Menu
81
Control Elements Menu
84
Inputs/Outputs Menu
85
Quick Settings Menu
86
Relay Configuration Menu
86
Logic Configuration Menu
88
IEC 103 Configuration Menu
89
Clock Menu
89
Actual Values Menu
90
Front Panel
90
Status
90
Metering
92
Inputs/Outputs Menu
93
Records Menu
93
Operations Menu
94
Communications Menu
94
Security Menu
96
View Menu
97
Help Menu
97
Human-Machine Interface (HMI)
98
Display
99
LED Indicators
100
Pushbuttons
100
Keypad and Shuttle Key
100
Command Push Button
102
Front Port and Cover Sealing System
102
Screen Contrast
103
Text Menus
103
Navigation
103
Text Menu Hierarchy
104
Actual Values
104
Snapshot Events
106
Fault Report
107
View Settings Menu
109
Change Settings
113
Date & Time
114
Commands
115
Passwords
116
Select Main Screen
118
Select Language
118
Graphic Display
119
One-Line Diagram
119
Metering Screen
120
All Events Screen
121
New Events Screen
123
Alarms Panel
124
Input/Output Monitoring Screen
125
Web Server
128
Home
128
Snapshot Events
129
Control Events
130
Alarms
131
Oscillography
132
Fault Report
133
Data Logger
134
Advertisement
GE Multilin F650 User Manual (323 pages)
Digital Bay Controller
Brand:
GE
| Category:
Controller
| Size: 16 MB
Table of Contents
Table of Contents
3
1 Getting Started
7
Important Procedures
7
Cautions and Warnings
7
Inspection Checklist
11
Safety Instructions
13
Overview
16
Introduction to 650 Family of Relays
16
Hardware Architecture
16
Communications Architecture
18
Enervista 650 Setup Software
20
System Requirements
20
Installation
20
Connecting Enervista 650 Setup with F650
23
Hardware
25
Mounting & Wiring
25
Communications
25
Faceplate Display
26
Maintenance
26
Storage
27
Repairs
28
Disposal
28
2 Product Description
29
F650 Overview
29
Ansi Device Numbers and Functions
30
Other Device Functions
31
Ordering Code
32
Technical Specifications
35
Protection Elements
35
Control
45
Monitoring
51
User-Programmable Elements
53
Metering
54
Inputs
55
Real Time Clock
57
Outputs
57
Control Power Supply
58
Communications
58
Optic Features
61
Environmental Characteristics
62
Packaging and Weight
62
Type Tests
62
Approvals
63
External Connections
64
3 Human Interfaces
67
Introduction
67
Values
67
Enervista 650 Setup Software Overview
67
Main Screen
69
Communication Menu
70
File Management
72
Enervista 650 Setup Menu Structure
76
File Menu Overview
77
Setpoint Menu Overview
86
Actual Values Menu Overview
97
Operations Menu Overview
101
Communication Menu Overview
101
Security Menu Overview
104
View Menu Overview
104
Help Menu Overview
104
Human Machine Interface (Hmi)
105
Display
106
Front Led Indicators
107
Pushbuttons
107
Front Port and Cover Sealing System
109
Screen Contrast
110
Text Menus
110
Graphic Display
133
Web Server 3.3.1 Home
142
Snapshot Events
143
Control Events
144
Alarms
145
Oscillography
146
Fault Report
147
Data Logger
148
4 Security
149
Adding Users
149
User Rights
149
Changing Passwords
150
Enabling Security
151
Loging into Enervista 650 Setup
152
5 Bootcode and Firmware Upgrade
153
Upgrade from Version below V7.00
153
Communication Parameters
154
Bootware Version Upgrade
155
Firmware Version Upgrade
163
Summary of Main Steps
172
Firmware Upgrade Version V7.00 or Higher
174
Introduction
174
Communication Parameters
174
Firmware Version Upgrade
175
Summary of Firmware Upgrade Main Steps (*)
181
GE Multilin F650 User Manual (259 pages)
Digital Bay Controller
Brand:
GE
| Category:
Controller
| Size: 4.01 MB
Table of Contents
Getting Started 1.1 Important Procedures 1.1.1
2
Table of Contents
2
Cautions and Warnings
6
Getting Started
6
Important Procedures
6
Inspection Checklist
9
Safety Instructions
11
Overview
12
Introduction to 650 Family of Relays
12
Hardware Architecture
12
Software Architecture
14
Communications Architecture
14
Enervista 650 Setup Software
16
System Requirements
16
Installation
16
Connecting Enervista 650 Setup with F650
20
Communications
22
Mounting & Wiring
22
Hardware
22
Maintenance
23
Faceplate Display
23
Product Description
26
Overview
26
F650 Overview
26
Summary
27
Ansi Device Numbers and Functions
27
Other Device Functions
28
Ordering Code
29
Technical Specifications
31
Protection Elements
31
Table of Contents
40
Control
41
To 900.00 S in Steps of 0.01 S Selectable by Setting
41
97% to 98% of the Pickup Level
42
Dropout Level
42
Level Accuracy
42
Of Operate Time or 50 Ms. (Whichever Is Greater)
42
Pickup Level
42
Snapshot Events
42
Timing Accuracy
42
To 900.00 S in Steps of 0.01 S ±3.5% of Operate Time or 50 Ms. (Whichever Is Greater)
42
Trip Delay
42
Selectable by Setting
43
To 900.00 S in Steps of 0.01 S
43
Ms at 50 Hz Typically
44
Monitoring
45
User-Programmable Elements
47
Metering
48
Outputs
51
Real Time Clock
51
Communications
52
Control Power Supply
52
Optic Features
54
Approvals
55
Environmental Characteristics
55
Packaging and Weight
55
Type Tests
55
External Connections
56
Enervista 650 Setup Software Overview
58
Human Interfaces
58
Introduction
58
Main Screen
60
Communication Menu
61
Enervista 650 Setup Menu Structure
67
File Menu Overview
68
Setpoint Menu Overview
72
Actual Values Menu Overview
80
Operations Menu Overview
83
Communication Menu Overview
84
Help Menu Overview
87
Security Menu Overview
87
View Menu Overview
87
Display
88
Human Machine Interface (Hmi)
88
Front Led Indicators
89
Pushbuttons
89
Front Port and Cover Sealing System
90
Text Menus
91
Graphic Display
110
Web Server 3.3.1 Home
119
Snapshot Events
120
Control Events
121
Alarms
122
Oscillography
123
Fault Report
124
Data Logger
125
Metering
126
Adding Users
128
Security
128
User Rights
128
Changing Passwords
129
Enabling Security
130
Loging into Enervista 650 Setup
131
Bootcode and
132
Introduction
132
Communication Parameters
133
Boot Code Upgrade
136
Firmware Upgrade
140
Firmware Version Upgrade
140
Boot Code Upgrade (*)
143
Firmware Upgrade (*)
143
Step List Summary for Versions 1.70 and Later
143
Commissioning
144
Visual Inspection
144
General Considerations on the Power Supply Network
145
Isolation Tests
146
Indicators
147
Power Supply Testing
148
Communications
149
Phase Currents
150
Verification of Measurement
150
Voltages
150
Active, Reactive Power, and Cosj Metering
151
Frequency
151
Digital Inputs
152
Inputs and Outputs
152
Circuit Continuity Supervision Inputs
153
Contact Outputs
153
Latching Circuits
153
Connections for Testing Protection Elements
154
Instantaneous Overcurrent (50Ph, 50Pl, 50N, 50G y 50Sg)
155
Time Overcurrent (51Ph, 51Pl, 51N, 51G and 46)
156
Directional Elements (67P, 67N, 67G, 67Sg)
157
Element
157
Element
159
67Sg Element
160
Element
161
Undervoltage Elements (27P, 27X)
161
Element
162
Overvoltage Elements (59P, 59X, 59Nh, 59Nl, 47)
162
59Nh and 59Nl Elements
163
Element - Neg Seq Ov
164
Frequency Elements (81O/81U)
165
Recloser
166
Reclosing Cycle
166
External Reclose Initiation
167
Recloser Status
167
Thermal Image Element
168
GE Multilin F650 Instruction Manual (20 pages)
Digital Bay Controller
Brand:
GE
| Category:
Controller
| Size: 0.33 MB
Advertisement
Related Products
GE Multilin GEK-113000T
GE F60 UR Series
GE F60
GE LOGIQ F6
GE FUF21S
GE Profile FUM13
GE FCM9DMEWH
GE FH1O
GE FCW
GE Multilin 489
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL