Legend to Fig. 63:
[1]
Dial
[2]
Mode selector
[3]
Advance button (activate heating immediately)
[4]
DHW single charge button (activate DHW mode immediately)
[5]
Menu button
[6]
Info button
[7]
Delete/Reset button
[8]
Menu up button
8.5
FW 200 heating control quick start
This is a quick reference to highlight the BASIC
programming of this control. For a more in depth
understanding or complete programming of the control,
please refer to the FW 200 Installation and Operating
manuals.
Instructions for programming
In the following description, at any time, pressing the
menu button ( Fig. 63, [3]) will bring you back to the
standard display.
8.5.1 Setting date and time
Set date and time upon initial start-up:
▶ Turn the dial
( Fig. 63, [1]) to adjust time and date.
▶ Press the dial
to confirm the setting.
You will be asked about system confi guration, which is only necessary if
you have added additional controls.
▶ Press and hold the menu button
prompt disappears.
Set Date and Time after intitial programming:
menu
▶ Press the menu button
( Fig. 63, [5]).
Vacation will be highlighted.
▶ Turn the dial
( Fig. 63, [1]) counter-clockwise until General
settings is highlighted.
▶ Press the dial
.
Time and date will be highlighted.
▶ Press the dial
.
Time will be highlighted.
▶ Press the dial
.
▶ Turn the dial
to adjust the time.
▶ Press the dial
to confirm the setting.
▶ Turn the dial
until Date is highlighted.
▶ Press the dial
.
▶ Turn the dial
to adjust the date.
▶ Press the dial
to confirm the setting.
8.5.2 Setting constant heating (no night set back)
This can be done two ways:
• By turning the selector ( Fig. 63, [2]) to the comfort symbol (
• Or by changing the programming.
To change programming:
menu
▶ Press the menu button
( Fig. 63, [3]).
Vacation will be highlighted.
▶ Turn the dial
one click counter-clockwise to highlight Heating.
Greenstar
menu
( Fig. 63, [5]) until this
▶ Press the dial
.
Program will be highlighted.
▶ Press the dial
.
Activate will be highlighted.
▶ Turn the dial
one click to highlight Edit.
▶ Press the dial
.
A:Program A will be highlighted.
▶ Press the dial
.
Replace with preset program will be highlighted.
▶ Turn the dial
counter-clockwise to highlight All days.
▶ Press the dial
.
P1 will be highlighted.
▶ Press the dial
.
The display will fl ash.
▶ Turn the dial
one click clockwise to 12:00PM.
▶ Press the dial
to confirm the setting.
▶ Turn the dial
until Comfort
The area around the display should fill in.
▶ Press the dial
to confirm the setting.
menu
▶ Press menu button
8.5.3 Setting type of heating system
There are three seperate default presets: Baseboard,
Radiators, Radiant Floor. They have an approximate
basepoint of 75 °F. With this basepoint, the heating
system will take some time to raise the room
temperature in warmer weather. Please see the FW 200
Installation and Operating Instructions, "Heating circuit
parameters" for more details on those presets. For a
custom preset, see below.
▶ To open INSTALLER SETTINGS: press and hold the menu button
menu
for approx. 5 seconds.
System configuration will be highlighted.
▶ Turn the dial
one click counter-clockwise to highlight Heating
parameters.
▶ Press the dial
.
Heating circuit 1 will be highlighted.
▶ Press the dial
.
Heating circuit type will be highlighted.
▶ Press the dial
.
Radiators will be highlighted.
▶ Press the dial
.
Radiators will fl ash.
▶ Turn the dial
to choose Baseline/Design temp.
▶ Press the dial
.
Heating circuit type will be highlighted.
▶ Turn the dial
counter-clockwise.
Base line will be displayed.
▶ Press the dial
and 78 °F (25 °C) will fl ash.
This is the supply temperature at 65 °F (18 °C) outdoor temperature.
▶ Set accordingly ( Fig. 64).
).
▶ Press the dial
to confirm the setting.
For hydroair systems, the minimum supply temperature
must be raised to the turn on temperature for that coil.
Commissioning | 53
appears.
to return to main display.
6 720 806 992 (2015/03)