hit counter script

Advertisement

Operating and Installation instructions
Rangehood
DA 428-4, DA 428-4 EXT
DA 429-4, DA 429-4 EXT
en - AU, NZ
To avoid the risk of accidents
or damage to the appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 09 201 520

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 428-4

  • Page 1 Operating and Installation instructions Rangehood DA 428-4, DA 428-4 EXT DA 429-4, DA 429-4 EXT en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Miele|home ........
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal injury resulting from incorrect or improper use and damage to property.
  • Page 5: Technical Safety

    Faulty components must only be the data plate correspond to the on-site replaced by genuine Miele original electricity supply, otherwise the parts. The manufacturer can only appliance could be damaged. Consult guarantee the safety of the appliance a qualified electrician if in any doubt.
  • Page 6 These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 Guide to the appliance Telescopic extension piece Touch control for grease filters Tower The indicator lamp for the grease filters lights up when the grease filters need Canopy to be cleaned. Control panel The touch control is used to reset the Grease filters operating hours counter every time the grease filters are cleaned (see...
  • Page 12: Description Of The Functions

    Description of the functions . . . air recirculation: The rangehood works with (available as an optional extra with a conversion kit and charcoal filter: see "Technical Data") . . . air extraction: The air is drawn in and cleaned first by The air is drawn in and cleaned by the the grease filter and then by a charcoal grease filters and directed outside.
  • Page 13: Miele|Home

    Miele electric rangehood. cooktop with onset controls. This module must be installed by a...
  • Page 14: Operation

    Operation To switch the fan on Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III. ^ Press the On/Off touch control. ^ To set this option, both the fan and The fan runs at power level "II".
  • Page 15: Run-On Option

    Operation Run-on option It is advisable to run the fan for a few minutes after cooking is finished to neutralise any lingering odours in the The indicator lamps for fan power levels air, whether you are using air extraction I and IV will flash if the automatic or recirculation mode.
  • Page 16: To Switch The Cooktop Lighting On

    Operation To switch the cooktop lighting Safety cut-out Should the rangehood be left on, the fan will switch off automatically after 10 The cooktop lighting can be switched hours. The lighting will remain on. on and off independently of the fan. ^ Briefly press the lighting control to ^ Pressing the On/Off control will switch on the cooktop lighting.
  • Page 17 Operation Reading the operating hours counter Altering the operating hours counter for the grease filters for the grease filters To check the percentage of time set The operating hours counter for the already used: grease filters is set at 30 hours. This can be lengthened or shortened to suit the type of cooking you do.
  • Page 18 Operation Activating and altering the operating hours counter for the charcoal filter (in recirculation mode) The charcoal filter is needed for The – / + control lamps show the time recirculation mode. which has been set: 1st lamp from the left = 20 hours On delivery, the operating hours counter 2nd lamp from the left = 30 hours for the charcoal filter is switched off.
  • Page 19 Operation ^ Use the – / + controls to select the Reading the operating hours counter desired time. for the charcoal filter To check the percentage of time set already used: ^ Confirm the selection by pressing the charcoal filter touch control. All the indicator lamps will go out.
  • Page 20: Cleaning And Care

    Important for appliances with conditioning agents are available to stainless steel housing order through your Miele Chartered (This infomation does not apply to the Agent, from Miele or via the internet at controls) www.miele-shop.com. Stainless steel surfaces can be cleaned Housing...
  • Page 21: Grease Filters

    Cleaning and care Grease filters Important for appliances with special finish The re-usable metal grease filters in the (Titanium and special order finishes) appliance remove solid particles (grease, dust, etc.) from the kitchen Please follow the information given in vapours, preventing soiling of the “General notes"...
  • Page 22 65°C programme, ensuring the spray ^ After replacing the grease filters, arm is not obstructed. If a Miele press the grease filter touch control dishwasher is being used, select the for approximately 3 seconds to re-set Sensor wash programme.
  • Page 23: Fitting And Replacing The Charcoal Filter

    New filters can be purchased from – if it is no longer effective in absorbing your Miele Chartered Agent or from kitchen odours. Miele. It should, however, be replaced at least See back cover for contact details, every 6 months.
  • Page 24: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the rangehood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall socket and the plug is withdrawn, or –...
  • Page 25: After Sales Service

    – your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 26: Appliance Dimensions

    For recirculation mode, only a connection socket needs to be fitted. Connection for air extraction C 150 mm (recommended), or C 125 mm with reducing collar. Please note, using 125 mm ducting limits through DA 428-4 put and thus rangehood performance. DA 429-4...
  • Page 27: Safety Distance (S)

    650 mm above gas cooktops. – The height of the cooking appliance If this rangehood is installed above a below must be taken into account Miele Wok CS 1028 CombiSet when planning the installation height appliance, a minimum safety of the rangehood.
  • Page 28: Installation

    Installation Assembly parts...
  • Page 29 Installation 3 protective sheets for use when fitting the tower. 1 exhaust connection for exhaust 6 screws 5 x 40 mm and ducting C 150 mm. 6 x S 8 plugs 1 reducing collar for securing the wall bracket. for exhaust ducting C 125 mm. The screws and plugs are 1 non-return flap designed for use in solid walls only.
  • Page 30: Installation Instructions

    Installation Dismantling Before installation, it is important to Should the appliance ever need to be read the information given on the dismantled, follow the installation following pages as well as the instructions in reverse order as "Appliance dimensions" and the described on the installation sheet.
  • Page 31: Connection For Air Extraction

    Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the rangehood at the same time as...
  • Page 32: Condensate Trap

    Connection for air extraction Condensate trap – Where ducting is horizontal, it must be laid to slope away at at least 1 cm (optional accessory) per metre. This is to ensure that condensate cannot drain back into the rangehood. – If the exhaust air is to be ducted into the open air, the installation of a telescopic wall vent or roof vent (available as an optional accessory)
  • Page 33: Silencer

    Connection for air extraction Silencer ...with air extraction: (DASD 150, optional accessory) The silencer not only reduces noise from the motor outside the house, but also sounds from outside (e.g. traffic noise). For this reason, the silencer must be positioned as close as possible to the ducting exit ...in recirculation mode: The silencer needs to be positioned...
  • Page 34: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation, an additional means of undertaken by a suitably qualified disconnection must be provided for all and competent person in strict poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 35: Operation With Control Module Dsm 400

    Operation with control module DSM 400 The Miele DSM 400 can be used to The components of the central combine the rangehood with other extraction system are not supplied as components. standard by Miele. It enables the following: If in any doubt, the advice of a competent builder must be sought.
  • Page 36: Technical Data

    Total rated load* Fan performance* DA 428-4 ....240 W Extraction power according to DA 429-4 ....260 W EN 61591 Fan motor* .
  • Page 40 Alteration rights reserved / 4511 M.-Nr. 09 201 520 / 01...

This manual is also suitable for:

Da 428-4 extDa 429-4 ext

Table of Contents