Operating instructions for Cooker Hood DA 78 It is essential to read these operating instructions before installing or using the machine, to avoid the risk of accident or damage to the machine. M.-Nr. 03 697 530...
Caring for the environment Caring for the environment Disposal of packing material Disposal of your old appliance The transport and protective packing Old appliances contain materials which has been selected from materials can be reclaimed or recycled. Please which are environmentally friendly for contact your dealer, your waste collec- disposal and can normally be recycled.
Warning and safety instructions Warning and safety instructions Technical safety This appliance meets statutory safety requirements. Inappropriate Before connecting the cooker use could, however, lead to risk of hood to the mains supply, make accidents to the user and damage sure that the voltage and frequency de- to the appliance.
Page 5
Warning and safety instructions The appliance is only completely Use of the appliance isolated from the electricity supply Never use an open flame beneath when, depending on the type of con- the cooker hood. To avoid the nection: danger of fire, do not flambé or grill - it is switched off at the fused unit or dishes.
Page 6
These can be obtained from the pliance. Miele Spare Parts department or from Pressurised steam could give rise to a builders’ merchants. short circuit or cause permanent dam-...
Page 7
Warning and safety instructions When using the cooker hood at the Disposal of your old appliance same time as another heating ap- Ensure that disconnection from the pliance which depends on the air in the mains supply is carried out by a room (eg gas, oil or coal fired heaters, competent person.
Description of the appliance Description of the appliance...
Page 9
Description of the appliance The cooker hood can be set up to oper- Controls ate by either air extraction or by air re- The control panel is on the right hand circulation. side of the cooker hood. The appliance is supplied from the fac- tory ready for connection as an extrac- –...
Operation Operation Switch on the fan After cooking The cooker hood will begin to operate If the air still needs to be cleared after at the level to which the power selec- cooking, it is recommended that the tor switch was last set.
Cleaning and care Cleaning and care Before carrying out maintenance An oversaturated filter is a fire ha- work, the cooker hood must be dis- zard! connected from the mains supply. ensure that, depending on the con- nection: - it is switched off at the fused unit or the fused unit switch is with- drawn, or - it is switched off at the wall socket...
Cleaning and care Changing the lamp and the Inserting and removing active starter charcoal filters If the cooker hood is connected for air Disconnect the cooker hood by recirculation, the active charcoal filters – switching off the mains switch must be installed in addition to the –...
Electrical connection Electrical connection nal in the plug which is marked with the Electrical connection letter E or by the earth symbol z or col- All electrical work should only be under- oured green or green and yellow. taken by a suitably competent person The wire which is coloured blue must in strict accordance with national and be connected to the terminal which is...
Installation Installation The extractor is designed to be built Building in into a chimney type cooker hood hous- Place the appliance in the cut-out ing. from below and align. Cut-out dimensions: 670 x 370 mm Connection for air extraction must be carried out only by a competent person.
Connection for air extraction Connection for air extraction – If the extraction ducting is to be laid Danger of toxic fumes horizontally, it should slope down- Please follow the advice in the sec- wards away from the cooker hood tion “Warning and safety instruct- with a minimum incline of 1 cm per 1 ions”...
Page 17
Connection for air extraction Important! If the exhaust ducting is to run through cool rooms, ceiling space etc where there may be great variations in tem- perature between the different areas, the problem of sweating or condensa- tion will need to be addressed. The exhaust ducting will need to be suitably insulated.
Connection – for cooker hood shafts which reach These parts are available from your the ceiling Miele Dealer or from the Miele Spare Parts Department. Install a directional grille, available from builders’ merchants, in the upper region of the chimney so that Connection –...
Page 20
Alteration rights reserved / 44 / 000 GB - 4597 This paper consists of cellulose which has been bleaches without the use of chlorine.