hit counter script
Miele Ventilation System Operating And Installation Instructions
Miele Ventilation System Operating And Installation Instructions

Miele Ventilation System Operating And Installation Instructions

Ventilation system

Advertisement

Quick Links

Operating and Installation Instructions
Ventilation System
To prevent accidents and machine damage, read these instructions
before installation or use.
en - US
M.-Nr. 09 973 040

Advertisement

Table of Contents
loading

Summary of Contents for Miele Ventilation System

  • Page 1 Operating and Installation Instructions Ventilation System To prevent accidents and machine damage, read these instructions before installation or use. en - US M.-Nr. 09 973 040...
  • Page 3: Table Of Contents

    Guide to the ventilation system ........
  • Page 4: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the ser-...
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS ,WARNING This appliance is not intended for use by persons (including children) TO REDUCE THE RISK OF with reduced physical, sensory or INJURY TO PERSONS IN THE mental capabilities, or lack of EVENT OF A COOKTOP experience and knowledge, unless they GREASE FIRE, OBSERVE THE have been given supervision or FOLLOWING...
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS Installation g) Do not install this hood over cooktops that burn solid fuel. ,WARNING h) Provided a larger distance is not TO REDUCE THE RISK OF given by the manufacturer of the FIRE, ELECTRIC SHOCK, OR cooktop, follow the minimum safety distances between a cooktop and the INJURY TO PERSONS, bottom of the hood given in the...
  • Page 8: Guide To The Ventilation System

    Guide to the ventilation system...
  • Page 9 Guide to the ventilation system a Suspension cables Sensor buttons b Canopy i Overhead lighting c OdorFree charcoal filter holders Use this button to turn the lighting On/Off and also adjust the brightness. d Grease filters j Fan On/Off e Control panel k Fan power selection The symbols serve as sensor buttons.
  • Page 10: Description Of Function

    Description of function The ventilation system works with air recirculation: The air drawn in is cleaned by the grease filters and then by 2 OdorFree charcoal filters. The cleaned air is then recirculated back into the kitchen through vents at the top of the hood.
  • Page 11: Operation

    Operation Turning the fan on s Automatically switching back from the intensive setting ^ Press the On/Off sensor button s. The intensive level can be programmed The fan turns on at power level 2. to automatically switch back to level 3 The On/Off button s and the 2 button after 10 minutes.
  • Page 12: Delayed Shut Down "5M15

    Operation Overhead lighting n Delayed shut down "5m15" It is best to let the fan run for a few The overhead lighting and the fan can minutes after cooking is completed to be turned on and off separately. neutralize any odors in the air. Turning the overhead lighting on The delayed shut down feature can be ^ Press the light sensor button n...
  • Page 13: Operating Hours Timer L

    Operation Operating hours timer l| To change the operating time: ^ Press the On/Off sensor button s to A timer records how many hours the hood has been in operation. turn the fan off. ^ Press the delayed shut down sensor The timer signals when the grease button m and the grease filter filters or the charcoal filters need to be...
  • Page 14 After cleaning, the timer will need to be The number of operating hours remains reset (see "Cleaning and care"). stored when the ventilation system is turned off or if there is a power failure. Setting the charcoal filter timer ^ Press the On/Off sensor button s to turn the fan off.
  • Page 15: Sensor Button Tone

    ^ Press and hold down the charcoal fil- ter button |. If the ventilation system has been disconnected from the power supply or One or more of the sensors 1 to 4 will after a power failure, the audible tone is flash.
  • Page 16: Cleaning And Care

    Cleaning and care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids, bleach or chlorides, INJURY TO PERSONS, – abrasive cleaning agents, OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, i.e. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 17: Grease Filters

    Use a wash program with a max. temperature of 150°F (65°C). In a Miele dishwasher use the "Normal" program. Use the recommended amount of dishwasher detergent. Overuse could destroy the filter.
  • Page 18: Resetting The Grease Filter Timer

    Cleaning and care ^ While the filters are removed, clean any dirt or grease from the filter casing. This reduces the risk of fire. ^ Replace the grease filters. Resetting the grease filter timer After cleaning the grease filter timer needs to be reset.
  • Page 19: Installing And Replacing The Odorfree Charcoal Filters

    Cleaning and care Installing and replacing the OdorFree charcoal filters Two charcoal filters are installed in addition to the grease filters. They are designed to absorb and neutralize cooking odors. The charcoal filters are installed in the ventilation hood below the recirculating vents.
  • Page 20: Resetting The Charcoal Filter Timer

    Cleaning and care Replace the charcoal filters when – the charcoal filter sensor | lights up – when the filter no longer absorbs odors efficiently. However, they should be changed at least every 2 years. Dispose of the charcoal filter with the household waste.
  • Page 21: Changing The Light Bulbs

    Cleaning and care Changing the light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Disconnect the exhaust hood from the power supply by either removing the fuse, unplugging it, or manually "tripping"...
  • Page 22: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 23: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most...
  • Page 24: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 25: Appliance Dimensions

    Appliance dimensions 1) Power cord, 5.9 ft. (1.8 m) long Keep the recirculating vents in mind during installation. If it is positioned to high the extraction will be inefficient. There should be a sufficient gap from the hood to the ceiling to allow air to flow freely from the vents. The distance should be at least 1 ft.
  • Page 26 Do not install this exhaust hood over cooktops that burn solid fuel. Provided a greater clearance is not specified by the manufacturer of the cooktop, observe the following minimum safety clearances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric cooktops 24"...
  • Page 27: Structural Support

    Structural support The mounting cables will support CAUTION the weight of the hood. The When cutting or drilling into the wall mounting cables must be attached or ceiling, do not damage electrical to rigid structural framing that is wiring or other hidden utilities. supported in its entirety by the ceiling joists, or to the ceiling joists directly.
  • Page 28: Installation

    Installation Installation accessories 4 screws 5 x 60 mm and 1 strain relief 4 anchors 8 x 50 for affixing the power cable to a ceiling for securing the ventilation hood to the fastener. ceiling. The screws and anchors are suitable for mounting on concrete ceilings.
  • Page 29: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or contact Miele’s Technical Service Department. See back cover for contact information. ,WARNING:...
  • Page 30: Technical Data

    Power cord length ..5.9 ft. (1.8 m) Weight ... . . 70.5 lbs (32 kg) Optional accessory: Miele OdorFree charcoal filter set: DKF 26-1 The set has two charcoal filters.
  • Page 31 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
  • Page 32 DA 7000 D en - US M.-Nr. 09 973 040 / 01...

This manual is also suitable for:

Da 7000 d

Table of Contents