Page 1
Operating and installation instructions Cooker hood DA 269-4 en - GB To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time. M.-Nr. 07 259 020...
Caring for the environment Disposal of the packing Disposal of your old appliance material Electrical and electronic appliances often contain materials which, if The transport and protective packing handled or disposed of incorrectly, has been selected from materials which could be potentially hazardous to are environmentally friendly for human health and to the environment.
Warning and Safety instructions This appliance is not intended for This appliance complies with all use by persons (including children) relevant local and national safety with reduced physical, sensory or requirements. Inappropriate use mental capabilities, or lack of can, however, lead to personal injury experience or knowledge, unless they and damage to property.
Page 5
Miele authorised person in accordance the data plate correspond with the with current national and local safety on-site electricity supply, otherwise the regulations.
Page 6
Warning and Safety instructions Do not connect the appliance to the Using at the same time as other mains electricity supply by a heating appliances that depend on multi-socket unit or an extension lead. the air from the room These do not guarantee the required safety of the appliance (e.g.
Page 7
The Miele DSM 400 control module offers the possibility of combining other appliance is switched off or vice versa. components with the cooker hood (see A ventilation brick alone is not generally sufficient to ensure safe ventilation.
Warning and Safety instructions Correct use Do not use the cooker hood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the cooker hood. To avoid the danger into the appliance and hindering its of fire, do not flambé...
Page 9
Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
Page 11
Guide to the appliance a Extension piece b Tower c Canopy d Touch controls e Grease filters f Recirculation grille (only for recirculation mode) g Hob lighting h Charcoal filter (special accessory for recirculation mode) i On/Off touch control for the fan j Controls to select fan power level k On/Off touch control for hob lighting...
Modes of operation The cooker hood works with . . . air extraction: . . . air recirculation: (available as an optional extra with a conversion kit and charcoal filter: see "Technical Data") The air is drawn in and cleaned by the grease filters and directed outside.
If the cooker hood has been To switch the lighting on and off connected to a window contact switch via the Miele DSM 400 control The hob lighting can be switched on module, then the fan cannot be and off independently of the fan.
Page 14
Operation ^ Press the + control to activate the Automatic switch-off of the Intensive setting automatic switch-off. The indicator lamps for fan power You can set the Intensive setting so that levels I and IV will now light up it only runs for 10 minutes before constantly.
It can (This infomation does not apply to the be washed 300 times. controls). Stainless steel surfaces can be cleaned using the Miele E-Cloth, or with a Housing proprietary non-abrasive cleaning agent designed specifically for use on General notes stainless steel.
Cleaning and care Important for appliances with lacquered housing (special order finish) It is very difficult to clean this type of surface without causing minor marks to the surface material. This can become particularly noticeable with darker colours and if there is halogen lighting in the kitchen.
New filters can be purchased from discolouration to the surface. your Miele dealer or from the Miele However, this will not affect the Spare Parts Department. functioning of the filters in any way.
Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Ensure that– – it is switched off at the wall socket and the plug removed, or– – it is switched off at the isolator, or- –...
Appliance dimensions Safety distance between hob and cooker hood (S) When planning the installation height of your cooker hood, the minimum safety distances between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance:...
Page 21
Installation a 3 protective sheets for use when fitting the tower. b 2 hose clips 2 x M 6 self-tapping nuts for securing the exhaust ducting. for securing the appliance. c 1 reducing collar for exhaust ducting C 125 mm. d 1 non-return valve 2 screws 3.9 x 7.5 mm for fitting into the exhaust connection...
Installation Dismantling Before installation, it is important to Should the appliance ever need to be read the information given on the dismantled, follow the installation following pages as well as the instructions in reverse order as "Appliance dimensions" and the described on the installation sheet.
Connection for air extraction Important: To avoid the danger If the exhaust ducting is secured to of toxic fumes, please observe the the exhaust stub by a hose clip, Warning and Safety instructions. ensure that it is fitted correctly. Do This is especially crucial when using not overtighten.
Connection for air extraction Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated.
Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety it is advisable to install and local safety regulations a suitable residual current device...
Operation with Control module DSM 400 The Miele DSM 400 Control module can If the control module is disconnected be used to combine the cooker hood in order to operate the cooker hood with other components. without the window contact switch It enables the following: (e.g.
Operation with Control module DSM 400 Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The tower needs to be removed before the control module can be fitted to the fan unit.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent – The Miele Customer Contact Centre (see back cover for address). When contacting your Dealer or the...
Level III ....250 m Level IV Intensive Setting ..350 m Special accessory for recirculation mode: – Conversion kit DUW 20 – Miele charcoal filter DKF 12-1...