  • Page 1 DINION IP 7000 HD NBN-71022 | NBN-71027 | NBN-71013 Installation manual...
  • Page 3: Table Of Contents

    DINION IP 7000 HD Table of Contents | en Table of contents Safety Safety message explanation Safety precautions Important safety instructions FCC and ICES compliance Notices Short information System overview DINION IP 7000 family Using the camera Operation with external systems...
  • Page 4 | Table of Contents DINION IP 7000 HD Browser connection 7.4.1 Establishing the connection 7.4.2 Protected network Troubleshooting Function test Resolving problems Testing the network connection Customer service Terminal program Maintenance Cleaning Repair Reset Decommissioning 10.1 Transfer 10.2 Disposal Technical data 11.1...
  • Page 5: Safety

    DINION IP 7000 HD Safety | en Safety Safety message explanation Caution! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Notice! Indicates a situation which, if not avoided, could result in damage to the equipment or environment, or data loss.
  • Page 6: Important Safety Instructions

    | Safety DINION IP 7000 HD Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings before operating the unit. Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
  • Page 7: Fcc And Ices Compliance

    DINION IP 7000 HD Safety | en FCC and ICES compliance FCC & ICES Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 8: Notices

    Notice! Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of losing information, we recommend multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 9: Short Information

    All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. More information For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com Bosch Security Systems 2014.09 | v1.0 | AM18-Q0674...
  • Page 10: System Overview

    DINION IP 7000 family The DINION IP 7000 family consists of high-performance HD surveillance cameras with superior imaging qualities: – DINION IP 7000 HD for intelligent HD surveillance – DINION IP dynamic 7000 HD for high dynamic range scenes –...
  • Page 11: Using The Camera

    Third-party integrators can easily access the internal feature set of the camera for integration into large projects. Visit the Bosch Integration Partner Program (IPP) website (ipp.boschsecurity.com) for more information. Using the camera To access the features of the camera, use a web browser.
  • Page 12: Operation With External Systems

    IP network. It is designed to work with Bosch security products as part of a total video surveillance management system. 2014.09 | v1.0 | AM18-Q0674...
  • Page 13: Planning

    Verify that all parts are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packaging is the safest container in which to transport the unit and can be used if returning the unit for service.
  • Page 14: Installation

    | Installation DINION IP 7000 HD Installation Lens mounting This procedure is only required for cameras not having a factory fitted lens. Notice! Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported. DC iris lens Damp - Damp + 2014.09 | v1.0 | AM18-Q0674...
  • Page 15 DINION IP 7000 HD Installation | en DC iris lens Drive + Drive - Remove the sensor protection cap from the camera (if present). Screw the lens onto the camera using the CS or C‑mount (use the adapter ring to attach a C-mount lens).
  • Page 16: Mounting The Camera

    | Installation DINION IP 7000 HD Mounting the camera Notice! Do not expose the image sensors to direct sunlight. Do not obstruct the free flow of air around the camera. 1/4”-20 UNC The camera can be mounted either from the top or from the bottom (1/4"...
  • Page 17: Local Storage

    DINION IP 7000 HD Installation | en Local storage Notice! Local storage on SD cards should only be used for alarm recording. To minimize the risk of losing information, use multiple, redundant recording systems and a procedure to back up all digital information.
  • Page 18: Connection

    | Connection DINION IP 7000 HD Connection Network (and PoE power) MENU 12VDC 24VAC CVBS Earth STP Cat 5e RJ45 Ethernet (PoE) Connect the earth terminal of the camera to the system earth of the installation to ensure correct safety and...
  • Page 19 DINION IP 7000 HD Connection | en Notice! Use only PoE approved devices. Power-over-Ethernet can be connected at the same time as a 12 VDC or 24 VAC power supply. If auxiliary power (12 VDC or 24 VAC) and PoE is applied simultaneously, the camera selects the auxiliary input and shuts off PoE.
  • Page 20: Auxiliary Power

    | Connection DINION IP 7000 HD Auxiliary power Caution! Installation should only be performed by qualified service personnel in accordance with the National Electrical Code (NEC 800 CEC Section 60) or applicable local codes. Caution! The Low Voltage power supply unit must comply with EN/UL 60950.
  • Page 21 DINION IP 7000 HD Connection | en Loosen the screws of the supplied 2-pole connector and insert the stripped wires, then tighten the screws again. Insert the 2-pole connector into the camera power socket. Bosch Security Systems 2014.09 | v1.0 | AM18-Q0674...
  • Page 22: Alarm

    | Connection DINION IP 7000 HD Alarm 5 mm (0.2 in) MENU CVBS Alarm 4 5 6 1 2 3 Alarm socket Alarm in 1 Alarm in 2 Alarm out contact 1 Ground Ground Alarm out contact 2 The maximum wire diameter is AWG 22-28 for both stranded and solid;...
  • Page 23 DINION IP 7000 HD Connection | en Alarm in: Use the alarm input to connect external alarm devices such as door contacts or sensors: – TTL logic, +5 V nominal, +40 VDC max, DC coupled with 50 kOhm pull-up to +3.3 V.
  • Page 24: Audio

    | Connection DINION IP 7000 HD Audio Line MENU CVBS Input Output Connect audio devices to the Audio In and Audio Out connectors. The unit has full-duplex mono audio for two-way communication between a speaker or door intercom system. The audio input signal is transmitted in sync.
  • Page 25: Video Monitor

    DINION IP 7000 HD Connection | en Video monitor MENU CVBS NBN-MCSMB (optional) Use the composite video connector (CVBS) on the camera to connect an analog monitor for setting up the camera or as a permanent analog output for viewing or recording: –...
  • Page 26: Data

    | Connection DINION IP 7000 HD Data 5 mm (0.2 in) MENU CVBS Data 4 5 6 1 2 3 Data socket Ground RxD / Rx+ Ground TxD / Tx- Use the data connector to connect to an external device for sending control data from the camera to the external device.
  • Page 27: Configuration

    DINION IP 7000 HD Configuration | en Configuration Setting the field of view When the camera is mounted and connected, its field of view and focus point must be set. To do this: Connect a monitor to the CVBS connector on the rear of the camera.
  • Page 28: Using The Install Wizard

    | Configuration DINION IP 7000 HD 7.1.2 Using the install wizard Power-up the camera and wait briefly before opening the camera install wizard. Briefly press Menu to start the wizard and display the following screen on the monitor: Lens type: DC Iris...
  • Page 29 DINION IP 7000 HD Configuration | en Briefly press Menu to start the automatic back focus adjustment (AUTO BACK FOCUS). – The motorized automatic back focus process runs. – The progress is shown on the monitor. If the camera is not in focus, press Menu for a longer time to restart the wizard.
  • Page 30: True Day/Night Switching

    | Configuration DINION IP 7000 HD True Day/Night switching The camera is equipped with a motorized IR filter. This mechanical IR filter is taken out of the optical path in low-light conditions. The IR filter is controlled either: –...
  • Page 31: Camera Configuration

    Configuration options using the menu system on the camera itself are limited to basic setup via the Wizard. 7.3.1 Bosch Video Client The Bosch Video Client is a free Windows application for viewing, operating, controlling, and administering surveillance cameras. It can be downloaded from: http://downloadstore.boschsecurity.com/...
  • Page 32: Browser Connection

    | Configuration DINION IP 7000 HD Browser connection A computer with Microsoft Internet Explorer is used to receive live images, control the unit, and replay stored sequences. The unit is configured over the network using the browser. 7.4.1 Establishing the connection The unit must have a valid IP address to operate on your network and a compatible subnet mask.
  • Page 33: Troubleshooting

    DINION IP 7000 HD Troubleshooting | en Troubleshooting Function test The camera offers a variety of configuration options. Therefore, check that it works properly after installation and configuration. This is the only way to ensure that the camera will function as intended in the event of an alarm.
  • Page 34 | Troubleshooting DINION IP 7000 HD Malfunction Possible causes Solution No connection Incorrect unit Check all established, no configuration. configuration image parameters (reset to transmission. factory default if necessary). Faulty installation. Check all cables, plugs, contacts and connections. Wrong IP address.
  • Page 35 DINION IP 7000 HD Troubleshooting | en Malfunction Possible causes Solution The audio voice Wait until the connection is already connection is free in use by another and then call the receiver. sender again. The unit does Alarm source is not...
  • Page 36 | Troubleshooting DINION IP 7000 HD Malfunction Possible causes Solution Incorrect firmware Enter the IP address file. of the unit followed by /main.htmin your Web browser and repeat the upload. Placeholder with JVM not installed on Install JVM. a red cross...
  • Page 37: Testing The Network Connection

    Check the IP address, subnet mask, and gateway address. Customer service If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to Bosch Security Systems Customer Service. The version numbers of the internal firmware can be viewed on a service page.
  • Page 38: Terminal Program

    | Troubleshooting DINION IP 7000 HD Terminal program Data Terminal If a camera cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the camera for initial setup and for setting important parameters.
  • Page 39 DINION IP 7000 HD Troubleshooting | en Assigning an IP Address Before you can operate a camera in your network you must first assign it an IP address that is valid for your network. The following default address is preset at the factory: 192.168.0.1...
  • Page 40: Maintenance

    | Maintenance DINION IP 7000 HD Maintenance Cleaning It is generally sufficient to use a dry cloth for cleaning, but a moist lint-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol cleaners.
  • Page 41: Decommissioning

    The camera should only be passed on together with this installation guide. 10.2 Disposal Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
  • Page 42: Technical Data

    | Technical data DINION IP 7000 HD Technical data 11.1 Specifications (NBN-71022) Power Power Supply 24 VAC 50/60 Hz 12 VDC Power-over-Ethernet 48 VDC nominal Current 400 mA | 500 mA IVA (12 VDC) Consumption 350 mA | 450 mA IVA (24 VAC)
  • Page 43 DINION IP 7000 HD Technical data | en Video streaming Video compression H.264 (MP); M-JPEG Streaming Multiple configurable streams in H.264 and M-JPEG, configurable frame rate and bandwidth. Regions of Interest (ROI) Overall IP Delay Min. 120 ms, Max. 240 ms...
  • Page 44 | Technical data DINION IP 7000 HD Video functions Day/Night Color, Mono, Auto White Balance ATW (2500 to 10000K), ATWhold and manual Shutter Automatic Electronic Shutter (AES) Fixed (1/30 [1/25] to 1/15000) selectable Default shutter Backlight Off, Auto compensation...
  • Page 45: Specifications (Nbn-71027)

    DINION IP 7000 HD Technical data | en 11.2 Specifications (NBN-71027) Power Power Supply 24 VAC 50/60 Hz 12 VDC Power-over-Ethernet 48 VDC nominal Current 500 mA (12 VDC) Consumption 450 mA (24 VAC) 175 mA (PoE 48 VDC) Power...
  • Page 46 | Technical data DINION IP 7000 HD Video streaming Video compression H.264 (MP); M-JPEG Streaming Multiple configurable streams in H.264 and M-JPEG, configurable frame rate and bandwidth. Regions of Interest (ROI) Overall IP Delay Min. 120 ms, Max. 240 ms...
  • Page 47 DINION IP 7000 HD Technical data | en Video functions Day/Night Color, Mono, Auto White Balance ATW (2500 to 10000K), ATWhold and manual Shutter Automatic Electronic Shutter (AES) Fixed (1/30 [1/25] to 1/15000) selectable Default shutter High dynamic range On/off...
  • Page 48: Specifications (Nbn-71013)

    | Technical data DINION IP 7000 HD 11.3 Specifications (NBN-71013) Power Power Supply 24 VAC 50/60 Hz 12 VDC Power-over-Ethernet 48 VDC nominal Current 400 mA | 500 mA IVA (12 VDC) Consumption 350 mA | 450 mA IVA (24 VAC)
  • Page 49 DINION IP 7000 HD Technical data | en Video streaming Video compression H.264 (MP); M-JPEG Streaming Multiple configurable streams in H.264 and M-JPEG, configurable frame rate and bandwidth. Regions of Interest (ROI) Overall IP Delay Min. 120 ms, Max. 240 ms...
  • Page 50 | Technical data DINION IP 7000 HD Video functions Day/Night Color, Mono, Auto White Balance ATW (2500 to 10000K), ATWhold and manual Shutter Automatic Electronic Shutter (AES) Fixed (1/30 [1/25] to 1/15000) selectable Default shutter Backlight Off / On / iAE (BLC)
  • Page 51: Common Specifications

    DINION IP 7000 HD Technical data | en 11.4 Common specifications Audio streaming Audio Streaming Full duplex / half duplex Signal-to-noise ratio > 50 dB Audio compression AAC-LC, G.711, L16 (live and recording) Input/output Analog video out CVBS (PAL/NTSC), 1 Vpp, SMB, 75 Ohm...
  • Page 52 10/100 Base-T, auto-sensing, half/full duplex Connectivity ONVIF Profile S, Auto-MDIX Software Unit Configuration Via web browser or Configuration Manager Firmware update Remotely programmable Software viewer Web browser, Bosch Video Client, or third party software 2014.09 | v1.0 | AM18-Q0674 Bosch Security Systems...
  • Page 53 DINION IP 7000 HD Technical data | en Optical Lens mount CS mount (C-mount with adapter ring) Lens connector Standard 4-pin DC-iris connector Lens Types Manual and DC-Iris auto-detect with override DC-iris drive: max. 50 mA continuous Lens Controls Wizard from web page or camera button...
  • Page 56 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven The Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2014...