hit counter script
Bosch Solution 16i User Manual
Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
����������������
User Guide
EN
Security System

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Solution 16i

  • Page 1 Solution 16i ���������������� User Guide Security System...
  • Page 2: Copyright Notice

    Notice to Owner Thankyou for selecting the Solution 16i Security Control Panel for your security needs. Your system includes many advanced features and functions which will be programmed and configured by your security consultant during installation. Depending on the configuration, and your access level, you may have the ability to program certain features within the system to suit changes in your security needs.
  • Page 3: Table Of Contents

    Set Part 2 Zones ............... 19 Smoke Sensor Reset ............19 Zone Name ................ 19 Walk Test All Zones ............20 Walk Test A Single Zone ..........20 Output Options ..............20 Output Status ..............20 Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 4: Programming Menu

    Pro grammi ng M en u The Solution 16i control panel includes an extensive range of features and options which enable your installer to taylor the system to suit your exact security requirements. The panel includes a number of user options which can be changed or modified by you if and when required.
  • Page 5: Introduction

    There are two basic types of zones, Non 24-hour and 24- hour. See below. Fe atures Non 24-Hour Zones Listed below are the main features of the Solution 16i Non 24-hour zones respond to alarm conditions depending control panel. upon whether the system is turned on or off. They are Up to 16 Fully Programmable Zones ...
  • Page 6: Reporting Alarms

    Hold for 2 seconds when you press and hold for two È Â Keypad Medical Alarm Hold for 2 seconds seconds. Table 3: Keypad Emergency Alarm Trigger’s Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 7: Status Icons / Led's

    Area is armed in Part On or Part On 2 mode. Tone 4 fast short beeps followed by a 5 second pause (repeat). PART Off The area is not turned Part On. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 8: Basic System Operation

    If your system has a faulted zone, you should return it to normal, or bypass the faulted zone. During exit delay, you may stop the system from turning Part On by entering your PIN followed by the [OFF] key. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 9: Turning The System Off

    If the PIN is invalid then a single long beep will be heard. If a valid PIN is not entered in time, the panel will attempt to establish a modem connection which sounds very similar Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 10: Programming Text Using The Keypad

    Make sure that the phone being used to remotely control the panel is set to transmit DTMF tones when keys are pressed during the call. This option is disabled by default on some phones. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 11: System Programming

    PIN. The keypad will now needs. The default PIN for User 1 (Master user) is 2580. prompt you to enter your new PIN again. Enter [Master PIN] + [MENU] Enter [1] + [1] + [2] + [OK]. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 12: Delete Pin

    Your system must have at least one reader enabled you to confirm the deletion. keypad for any token functions to work. Del ? 4. Press [OK] to delete the PIN, or press [MENU] to cancel. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 13: Delete Token

    When prompted enter the RF keyfob ID number. Press [OK] when finished Ent Id Enter the RF Keyfob’s ID Number or alternatively press any button on the keyfob to automatically delete the ID number. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 14: User Name

    When the user name is complete, press [OK] to save Master users can now restrict the user(s), by linking them and exit, or press [MENU] to exit without saving. to the appropriate timer group. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 15: Timer Group

    Areas user can only be assigned to one Timer Group. Setting this The Solution 16i control panel has the ability to be option to 0 will give the user 24 hour access to the system. partitioned up to 4 individual areas. Each area can be Enter [Master PIN] + [MENU] independantly controlled.
  • Page 16: Turn Area On

    At least one keypad In the example below chime mode “ IS OFF”. on the system must be in a diasrmed area before you can access this command. Enter [Master PIN] + [MENU] Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 17: Chime Mode

    Table 9: Default Area Names The set the chime mode. Enter [Master PIN] + [MENU] Enter [2] + [0] + [6] + [OK]. If your system has been configured for multiple areas you will be prompted Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 18: Input Options

    Repeat step 3 for any additional chime zones. fire or 24-Hr non fire zones will need to be manually un- 5. Press [OK] to save and exit, or press [MENU] to exit bypassed. without saving. Enter [Master PIN] + [MENU] Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 19: Set Part 2 Zones

    When the Zone Name is complete, press [OK] to save reset. and exit, or press [MENU] to exit without saving. If your system is configured for multiple areas you may be asked to select the area to reset. Note Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 20: Walk Test All Zones

    This menu allows you to manually control system outputs that have been programmed by your installer. Outputs can be programmed to control sirens, strobe lights, outside 4. Press [OK] to exit when finished. lighting, pool pumps, watering systems etc. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 21: Output Name

    Enter [4] + [1] + [0] + [OK]. The keypad will display configured to have more than one area, the keypad the Op = prompt. Enter the Output number you will display the A = prompt. want to program, then press [OK]. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 22: Strobe Test

    When you turn on call forwarding, the control information for telephone number 1. panel will automatically activate and de-activate the call forward on and call forward off sequence accordingly when you turn your system On and Off (arm and disarm). Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 23: Call Forward On Number

    #61# The default sequence A61PA20H is explained H61H below. You should modify this sequence to suit your particular requirements or ask your installer to configure for you. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 24: User Ras Pin

    Press [OK] or [MENU] to exit. Displays the keypad 16 Zn size. 8 Zone or 16 Zone Displays if the keypad has an inbuilt proximity reader. 4. Press [OK] or [MENU] to exit. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 25: Volume

    Min = 1, Max = 10, 0 = Off Press [OK] to save and exit, or press [MENU] to exit When finshed press [OK] to exit. The system will without saving. automatically exit this menu after 30 seconds. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 26: History Log

    Event Result. S1-L2 Use the [←] and [→] keys at any time to confirm S1 = Reported event programming and then press [OK] or [MENU] to exit. to route 1 L2 = Logged the event Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 27: Summer Time On

    Sunday in March. Daylight Saving Begins Daylight Saving Ends Turn Clock Ahead 1 hr Turn Clock Back 1 hr Sun 28 Oct 2007 Sun 30 Mar 2008 Sun 26 Oct 2008 Sun 29 Mar 2009 Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 28: Schedules

    Enter [7] + [5] + [0] + [OK]. The keypad will display the sh = prompt. Enter the Schedule number you Enter the schedule start time minutes. want to program, then press [OK]. Allowable values are 01 to 59. SMM=00 Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 29: Day

    4. Repeat Step 3 until you have set all requred days for the schedule. The above example shows the schedule operating on Monday, Tuesday, Wednesday, Friday and Saturday. 5. Press [OK] to save and exit, or press [MENU] to exit without saving. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 30: Start / Stop Day

    Any zone that has been successfully tested will no longer be displayed on the keypad display. Use the [←] and [→] keys to confirm programming and then press [OK] to exit. When all zones have been tested, the keypad will display PASS. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 31: Battery Test

    If the test passes the keypad will display: PAss If the test fails the keypad will display. If this happens you should contact your installer. FAil Press [OK] to exit. Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 32 Service Mode SERViC The security installer has entered service mode. PHONE Phone In Use The phone in use ICON will come on when the system is using the phone line. Table 14: Trouble Messages Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 33: Installation Details

    Zone 8   Zone 9   Zone 10   Zone 11   Zone 12   Zone 13   Zone 14   Zone 15   Zone 16 Notes: Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 34: Index

    What Is A Faulted Zone ............5 What Is A Zone ..............5 Holidays Service Required ..............32 Naming Holidays ..............29 Silencing Alarms ............... 9 Set Start/Stop Times ............30 Silent Alarms ................9 Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 35 Name .................. 14 User PIN ................9 Walk Test All Zones ............... 20, 30 Zone 24-Hour Zones ..............5 Bypass Command ............... 18 Chime ................. 18 Non 24-Hour Zones ............. 5 Part 2 Zones ............... 19 Bosch Security Systems 10/07 BLCC500U FTR1.01...
  • Page 36 Bosch Security Systems 25 Huntingwood Drive Huntingwood, NSW 2128 Australia Phone: +612 9672 1777  RoHS Facsimile: +612 9672 1717 N12138 N12138 © 2007 Bosch Security Systems BLCC500U 926345 Issue FTR1.01...

Table of Contents