52/64
Maintenance and repair
Bosch Rexroth AG, Accumulator shut-off block type ABZSS, 0532VAW, RE 50129-B/02.19
10.4 Maintenance
▶
Perform maintenance at the intervals specified in the maintenance schedule of
the machine/system manufacturer.
Seals of attached and installed hydraulic components are subject to a natural
process of wear and aging. Bosch Rexroth recommends replacement at
appropriate time intervals. The intervals are mainly determined by the operating
conditions and the cleanliness of the hydraulic fluid.
▶
As a precaution, exchange seals at reasonable time intervals.
Preventive maintenance (e.g. hydraulic fluid care) as well as compliance with the
pressure and temperature specifications extend the life cycle of the system
and/or the accumulator shut-off block.
10.4.1 Maintenance work process
Prior to maintenance, perform the following work steps:
▶
Get the data sheets of the components to be assembled and disassembled
according to the parts list ready.
▶
Prepare a suitable and clean tank for temporary storage of the components to be
assembled.
▶
Prepare suitable tools.
▶
Depressurize the system and de-energize the electrical control system.
▶
Open the manual relief.
▶
Close the system shut-off cock.
After maintenance, check the following points:
▶
Make sure that the fluid ports are connected according to specifications and that
the gas port is tight and covered by the protective cap.