4.3.13
Transponder comm port setup dialog
Go to menu Setup > Transponder comm port setup... This dialog connects the communication
port indexes set for each transponder in the Transponder Database to the physical
communication ports on the computer.
2019.08 | V2.18.1.6 | DOC
settings. Change this setting if there are known problems with
the location using the "Low Algorithm". The Enable Algorithm
Tweaks checkbox must be checked for this to be displayed.
This setting controls the involvement of receivers in the alarm
location calculation only when the "Medium Algorithm" is being
used. The setting can range from 0 to 6 (default is 2). When set
to 0, only the receivers closer to the actual location of the alarm
will be considered in the location calculation. As the setting is
raised, more distant receivers will be included in the alarm
calculation. Typically, lower settings are better than higher
settings. Change this setting if there are known problems with
the location using the "Medium Algorithm". The Enable
Algorithm Tweaks checckbox must be checked for this to be
displayed.
This setting controls the involvement of receivers in the alarm
location calculation only when the "Strong Algorithm" is being
used. The setting can range from 0 to 6 (default is 2). When set
to 0, only the receivers closer to the actual location of the alarm
will be considered in the location calculation. As the setting is
raised, more distant receivers will be included in the alarm
calculation. Typically, lower settings are better than higher
settings. Change this setting if there are known problems with
the location using the "Strong Algorithm". The Enable Algorithm
Tweaks checkbox must be checked for this to be displayed.
Four alarm zones allow the selection of which alarms from
specific transmitters are reported on this workstation. This
workstation displays the alarms only for the alarm zones that are
checked. Each transmitter can be assigned to one or more alarm
zones and when that transmitter generates an alarm (if this
workstation has one or more of the same alarm zones checked),
that alarm is displayed. The system defaults to all alarms
displayed on all workstations.
Save the changes and close the dialog window.
Cancel the changes and close the dialog window.