hit counter script
Download Print this page
Bosch FERION 5000 OW Manual

Bosch FERION 5000 OW Manual

Wireless smoke alarm
Hide thumbs Also See for FERION 5000 OW:

Advertisement

Wireless Smoke Alarm
FERION 5000 OW
en

Advertisement

loading

Summary of Contents for Bosch FERION 5000 OW

  • Page 1 Wireless Smoke Alarm FERION 5000 OW...
  • Page 3: Table Of Contents

    Wireless Smoke Alarm Table of Contents | en Table of contents Graphics Introduction Mounting Radio Network Maintenance Technical data Customer Service Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 4: Graphics

    | Graphics Wireless Smoke Alarm 1 Graphics minimum additional unsuitable repeater ON (2.A) (2.B) (2.C) (2.D) ≤1m >1m 0-20° 0.5m >20° >20° >20° 08.15 | 2.1 | F.01U.309.850 Bosch Sicherheitssysteme GmbH...
  • Page 5 Wireless Smoke Alarm Graphics | en 1 x 3 mm 2 x 3 mm 60 mm < 2 s Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 6: Introduction

    | Graphics Wireless Smoke Alarm 2 Introduction The FERION 5000 OW wireless smoke alarm device with built‑in long-life battery, built‑in siren (4.1), alarm LED (4.2), emergency light (4.3) and big button for operation (4.4) is solely designed for residential applications. The device reliably warns you of the emergence of a fire in your house or flat.
  • Page 7: Mounting

    1. Determination of the mounting locations. (1) Observe the information regarding Unsuitable locations for mounting, page 8, and regarding Audibility, page 8. Each device is to be Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 8 3. For each device: Mounting the base. (5) Observe the mark (5.2) for adjusting the emergency light and the marks (5.1) for alignment with BOSCH label/siren. 4. Functional check, page 12, for each device after setting it up into operation. (6) (7) Unsuitable locations for mounting –...
  • Page 9: Radio Network

    (6) 4 Radio Network Up to 40 FERION 5000 OW can be interconnected to create a network. Thus, an alarm is raised at all devices giving the chance to react faster to a distant fire. Before mounting to the ceiling, position the devices you want to connect next to each other.
  • Page 10 To send a radio test signal, press and hold the button for about 4 s until the LED flashes orange (connecting). 2. Press and release the button (< 2 s). 08.15 | 2.1 | F.01U.309.850 Bosch Sicherheitssysteme GmbH...
  • Page 11 (1) See also www.boschsecurity.com/ferion/. 1. If the device is in normal mode (no optical signal) press and hold the button for about 4 s until LED flashes orange (connecting). Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 12: Maintenance

    A visual inspection and a functional check must be done for each device monthly. After the functional check the device is muted for 10 min, even when an alarm will be triggered. 08.15 | 2.1 | F.01U.309.850 Bosch Sicherheitssysteme GmbH...
  • Page 13 If the siren sounds short once every 3 h the device indicates weak battery of another device in the network. The device with weak battery sounds every 43 s and must be replaced. Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 14: Technical Data

    ** during standard usage and operation as stated in the user guide *** based on typical storage temperature (-5 … +30 °C) and typical operating temperature (+5 … +30 °C) and monthly functional tests 08.15 | 2.1 | F.01U.309.850 Bosch Sicherheitssysteme GmbH...
  • Page 15 3 x ≥85 dB(A) emergency light Alarm flashes red fast, 3 x ≥85 dB(A) / 4 emergency light Muted flashes red 1 x / 10 s for 10 min Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.850...
  • Page 16: Customer Service

    1 x / 3 h 1 x short / 3 h another device LED test LED change: red, green, orange 7 Customer Service Replacement of the product is only possible with proof of purchase during guarantee. 08.15 | 2.1 | F.01U.309.850 Bosch Sicherheitssysteme GmbH...
  • Page 17 Wireless Smoke Alarm Graphics | en Great Britain Ireland Robert Bosch Ltd. (B.S.C.) Origo Ltd. P.O. Box 98 Unit 23 Magna Drive Broadwater Park Magna Business Park North Orbital Road City West Denham Dublin 24 Uxbridge Tel. Service: UB 9 5HJ (01) 4666700 Tel.
  • Page 20 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2015...