hit counter script

Measuring Cross Channel Phase; Setup - GE SCOUT100-Ex Reference Manual

Table of Contents

Advertisement

Measuring Cross Channel Phase

The Cross Channel Phase measurement option has been enhanced. It's
easier to change the speed of interest during the recording. This could
be the actual speed of the machine or the frequency of interest.
Additionally you can choose the required filter bandwidth you wish to
monitor, and the number of averages you wish to take. While recording,
a graph displays on your screen, showing your data. You can adjust the
position of the cursor on this graph to access more details about a peak
of interest, including phase and coherence data.

Setup

To select your preferred settings for a cross channel phase recording:
1.
Connect two sensors to the appropriate machine locations.
2.
Assign two sensors and enable both channels:
a. Press
b. Create or select your sensors as required.
c.
Press
NOTE: The lowest channel will be used as the reference channel.
For example, if you have enabled CH2 and CH3, CH2 will be used
as the reference channel.
3.
Press
or
4.
Use the navigation keys provided to locate and select Cross
Channel Phase > Press
5.
Press
Store Units > Select ONE of these units according to
your requirements:
Acceleration
Velocity
Displacement
6.
Press
.
7.
Press
Speed/Freq of Interest.
8.
Enter the required rpm value > Press
9.
Press
Filter Bandwidth > Select the required bandwidth.
Section 4 — Measurement Types and their Uses
> Press
Sensor Setup.
to continue.
Measure.
.
.
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scout140-exVb6Vb7Vb8Vb5

Table of Contents