hit counter script
Bosch BE 300 LSN User Manual
Hide thumbs Also See for BE 300 LSN:

Advertisement

Quick Links

User's Guide
Contents
Introduction, security and safety ............................................. 2
Explanation of displays ............................................................. 3
Explanation of keys................................................................... 4
Notes on user code................................................................... 6
Notes on coded mode............................................................... 7
User authorization..................................................................... 8
Perimeter arm with door contact ............................................... 9
Perimeter arm ......................................................................... 10
Arming with door contact ........................................................ 11
Arming .................................................................................... 12
Disarming with door contact.................................................... 13
Disarming................................................................................ 14
Arming .................................................................................... 15
Disarming................................................................................ 15
Arming .................................................................................... 16
Disarming................................................................................ 16
BE 300 LSN
4.998.099.747 A2
External alarm, internal alarm, malfunctions........................... 17
Display message .................................................................... 18
Display faulted points.............................................................. 19
Reset message....................................................................... 20
Notes on menu use................................................................. 21
View all detectors.................................................................... 22
View alarm counter ................................................................. 23
View event log ........................................................................ 24
Change own user code........................................................... 25
Change user code for new user.............................................. 26
Display/change date and time ................................................ 27
Display test ............................................................................. 29
Bypass ..................................................................................... 30
Enable/Disable detector.......................................................... 31
Walktest ................................................................................... 32
1

Advertisement

Table of Contents
loading

Summary of Contents for Bosch BE 300 LSN

  • Page 1: Table Of Contents

    Notes on coded mode............... 7 View all detectors..............22 User authorization..............8 View alarm counter ..............23 Arming/Disarming with BE 300 LSN (user code) View event log ................ 24 Perimeter arm with door contact ..........9 Change own user code............25 Perimeter arm .................
  • Page 2: Introduction, Security And Safety

    Scharfschalten der Anlage Introduction, security and safety What do these operating instructions tell you about? Notes on cleaning: Here you will find all the information you need to perform the When cleaning surfaces, especially the display/control panel, jobs listed in the contents fast and reliably. avoid the use of corrosive and scouring agents, and make sure no fluid gets inside the equipment.
  • Page 3: Display/Keys

    If the keypad unit is on standby, ie no messages Perimeter Disarm have arrived and no operation is initiated, the display shows the standby image. Bypass Disable Reset NZ 300 LSN BOSCH Walktest Status Code Keys: These keys are explained on the next page. Clear Menu Escape Turn off buzzer: Press any key.
  • Page 4: Explanation Of Keys

    Display/Keys Explanation of keys Use this key and the user code to perimeter arm Use this key and the user code to arm partitions. partitions. Perimeter Use this key and the user code to disarm parti- Use this key to bypass detectors or parts of the tions.
  • Page 5 Display/Keys Explanation of keys Use this key to call up the menu. Use this key to go back one step or terminate a function without completing it. Menu Escape This key has no function at present. Use this key to confirm an entry, eg after entry of the user code.
  • Page 6: User Code/User Authorization

    Notes on user code User authorization: User number: BE 300 LSN can be operated by several users with different au- The user number consists of two digits. The number (01, 02, thorizations. etc to 40) is firmly assigned to the user in programming and cannot be changed.
  • Page 7: Notes On Coded Mode

    Code ? Code NZ 300 LSN Coded BOSCH Enter your user code If no key is pressed for 1 min in coded mode, standby is initi- (user number + user password, eg 02 ..). ated.
  • Page 8: User Authorization

    User code/User authorization User authorization BE 300 LSN can be operated by maximally 40 users with different authorizations. User authorizations are issued in programming by selecting System-Manager, User level 1 or User level 2. Installer * System- User User Programmer...
  • Page 9: Arming/Disarming With Be 300 Lsn (User Code)

    Arming/Disarming with BE 300 LSN (user code) Perimeter arm with door contact Press the “OK“ key. Activation of the internal program is Press the “Perimeter“ key. started. Perimeter arm The door contact is not activated until after the activation de- Code ? lay.
  • Page 10: Perimeter Arm

    Arming/Disarming with BE 300 LSN (user code) Perimeter arm Press the “OK“ key. Activation of the internal program is Press the “Perimeter“ key. started. After activation the standby image appears on the display. Perimeter arm Code ? Perimeter Perimeter arm in preparation Enter the user code and confirm your entry with the “OK“...
  • Page 11: Arming With Door Contact

    Arming/Disarming with BE 300 LSN (user code) Arming with door contact Press the “OK“ key. Activation of the areas is started. Note: Arming with a user code is only possible for pro- grammed areas without a block-type lock. The areas must not The door contact is not arm until after the arming delay.
  • Page 12: Arming

    Arming/Disarming with BE 300 LSN (user code) Arming Press the “Arm“ key. Press the “OK“ key. Activation of the areas is started. After arming the standby image appears on the display. Code ? in preparation NZ 300 LSN Enter the user code and confirm your entry with the “OK“ key.
  • Page 13: Disarming With Door Contact

    Arming/Disarming with BE 300 LSN (user code) Disarming with door contact Triggering a door contact in the entrance areas produces a display of the time to deactivate. The buzzer sounds at inter- vals (faster for the last 10 s). Disarm in 15 s Press the "Disarm"...
  • Page 14: Disarming

    Arming/Disarming with BE 300 LSN (user code) Disarming Press the “Disarm“ key. Press the “OK“ key. Disarming is activated and the standby The display shows "perimeter disarm" or "disarm". image appears on the display. Disarm NZ 300 LSN Code ?
  • Page 15: Arming/Disarming With Block-Type Lock

    After arming of the areas this will be signaled by a buzzer NZ 300 LSN or LEDs on the block-type lock. BOSCH Notes: NZ 300 LSN is on disarmed standby. If arming is not possible, a triggered detector can be exempted from surveillance (refer to chapter “By-...
  • Page 16: Arming/Disarming With Key Switch

    Arming/Disarming with key switch Arming Disarming Note: The key switch and BE 300 LSN belong to the same Triggering a door detector produces a display of the time left areas. until disarming. The buzzer sounds at intervals (faster for the last 10 s).
  • Page 17: Message Display/Editing

    Number of messages: The + sign on the display indicates that several messages are present. Perimeter Disarm Turn off buzzer: Use any key to turn off the buzzer of BE 300 LSN. Bypass Disable Reset Turn off external sounder: Walktest...
  • Page 18: Display Message

    Message display with user code: Detector 12 Messages are displayed that belong to the user areas and Intrusion 19.09 the areas of BE 300 LSN. Duress alarms messages are Detector 12 displayed. Further operations: Refer to chapter “Bypass“. Refer to chapter “Enable/Disable detector“.
  • Page 19: Display Faulted Points

    Faulted points are displayed that belong to the user ar- Use the paging keys to scroll up and down through the faulted eas and to the areas of BE 300 LSN. points. Detectors are displayed in the order of their program- ming.
  • Page 20: Reset Message

    User authorization: The user must be authorized to reset. NZ 300 LSN BOSCH If the user is not authorized to reset, No authorization to the display will show the following.
  • Page 21: Use Of Menus Notes On Menu Use

    Use of menus Notes on menu use Use of menus without user code. Use of menus with user code. Press the “Code“ key. Enter the user code and confirm your Press the “Menu“ key. entry with the “OK“ key. The first menu “View detector“ is displayed. Press the “Menu“...
  • Page 22: View All Detectors

    The detectors in the user areas are displayed. Viewing detectors without user code: Intrusion The detectors belonging to the areas of BE 300 LSN Detector 6 are displayed. From point 2 onwards this is identical to viewing with user code.
  • Page 23: View Alarm Counter

    Quit the menu or coded mode with the “Clear“ key. The standby image appears on the display. Menu View detector NZ 300 LSN BOSCH Clear Use the paging keys to scroll up and down through the menus. Select the “Alarm counter“ menu. Menu Alarm counter Press the “OK“...
  • Page 24: View Event Log

    Quit coded mode with the “Clear“ key. The standby image ap- pears on the display. Menu Event log NZ 300 LSN BOSCH Press the “OK“ key. The latest event in event log is displayed. Clear The display changes between time and date every 2 s. Intrusion...
  • Page 25: Change Own User Code

    Press the “Escape“ or “Clear“ key. Press the “OK“ key. The "Escape" key takes you back one step. Further operations are then possible. New code Code ? Quit coded mode with the "Clear" key. The standby image appears on the display. NZ 300 LSN BOSCH...
  • Page 26: Change User Code For New User

    Now enter a new user password (this entry does not appear NZ 300 LSN on the display). BOSCH Clear (user code = user number + user password) Confirm your entry with the “OK“ key. Repeat code...
  • Page 27: Display/Change Date And Time

    Quit coded mode with the “Clear“ key. The standby image ap- Date/time pears on the display. 13.04.01 11 : 23 NZ 300 LSN BOSCH Position the cursor with the paging keys to overwrite the digit Clear to be changed. Date/time 13.04.01 11 : 23...
  • Page 28: Sw Version Be 300 And Nz 300, Programming Date

    Menu View detector Menu NZ 300 LSN BOSCH Clear Use the paging keys to scroll up and down through the menus. Select the “SW version BE 300“ or “SW version NZ 300“ or “Programming date" menu.
  • Page 29: Display Test

    Menu standby image appears on the display. View detector Menu NZ 300 LSN Use the paging keys to scroll up and down through the menus. BOSCH Clear Select the “Test display“ menu. Menu Test display Press the “OK“ key. The buzzer sounds. The "Operative" LED extinguishes, the "Alarm"...
  • Page 30: Bypass

    Bypass must be made in coded mode. The areas must be Quit coded mode with the "Clear" key. disarmed. NZ 300 LSN Call up the detector that is to be exempted from surveillance (By- BOSCH Clear pass). Refer to the chapters above for details. Arm the system. Malfun.
  • Page 31: Enable/Disable Detector

    Quit coded mode with the "Clear" key. Malfun. 15:21 Detector 10 NZ 300 LSN BOSCH Clear Press the “Code“ key. Enter the user code and confirm your entry with the “OK“ key. Enable: When detectors are to be enable again, the steps are analo- gous to disabling as explained here.
  • Page 32: Walktest

    Quit coded mode with the "Clear" key. The standby image ap- pears on the display. Trigger all detectors of the areas. This is shown on the display NZ 300 LSN and entered in event log. BOSCH Clear Walk ∑ = 12 Detector 012...

Table of Contents