Manuals and User Guides for GE Security Simon 600-1012. We have
2
GE Security Simon 600-1012 manuals available for free PDF download: Installation Instructions Manual, User Manual
GE Security Simon 600-1012 Installation Instructions Manual (88 pages)
Brand:
GE
| Category:
Security System
| Size: 0.92 MB
Table of Contents
Table of Contents
4
About this Manual
9
Special Installation Requirements
9
UL Listed Installations
9
SIA System Requirements
10
Central Station Reporting
11
UL Canada Listed Installations
11
California State Fire Marshall Listed Installations
11
Planning the Installation
12
Standard Panel
12
System Overview
12
System Components
12
Control Panel
12
System Devices
13
Panel Tamper
13
Planning Sensor Types & Locations
15
Device Locations
15
Control Panel
15
Remote Handheld Touchpad
16
QS1500 Keypad
16
Keychain Touchpad
16
Dialog Telephone Interface Module
16
X10 Modules
16
House Code and Unit Numbers
16
Manually Controlling Lights
16
Installing the System
17
Materials Needed
17
Opening the Panel Cover and Chassis
17
Mounting the Panel
18
Wall Mounted Panel
18
Tabletop Mounted Panel
18
Connecting Hardwire Devices
19
AC Terminals
19
HWIN1, HWIN2, and DCOUT Terminals
19
Wiring Interior Sirens
19
LD105 Hardwire Interior Siren
20
Wiring Exterior Sirens
20
Hardwire Exterior Siren with Supervision
20
Hardwire Exterior Siren Without Supervision
21
Wiring Hardwire Contacts
21
Wiring a Phone Line to the Panel
21
Full Line Seizure
22
No Line Seizure
23
Wiring the Power Transformer
23
Powering up the Panel
23
Installing the Panel Backup Battery
23
Applying AC Power
24
Installing X10 Modules
24
Lamp and Appliance Modules
24
Universal Module
24
Sensor Installation
25
Programming
25
Entering Program Mode
25
Exiting Program Mode
25
Reset Memory to the Factory Defaults
25
Set the Clock
25
Adding (Learning) Sensors
26
X10 Module Operation
28
Ethernet Interface Module
29
Requirements
29
Activate the Ethernet Interface Module
29
Numbered Options
30
Option 01: Panel Piezo Beeps
30
Option 02: Panel Voice
31
Option 03: Latchkey
32
Option 04: Primary Phone Number
32
Option 05: Secondary Phone Number
33
Option 06: Downloader Phone Number
33
Option 07: Account Number
33
Option 08: Phone Lock
34
Option 09: Downloader Code
34
Option 10: Entry Delay
34
Option 11: Exit Delay
35
Option 12: Phone 1 Reports
35
Option 13: Phone 2 Reports
35
Option 14: DTMF Dialing
36
Option 15: no Activity Timeout
36
Option 16: Auto Phone Test
37
Option 17: Dialer Delay
37
Option 18: Alarm Cancel Report
37
Option 19: RF Timeout
38
Option 20: Manual Phone Test
38
Option 21: Opening Reports
38
Option 22: Closing Reports
39
Option 23: Force Armed Report
39
Option 24: AC Power Failure Report
39
Option 25: CPU Low Battery Report
40
Option 26: Fail to Communicate
40
Option 27: Ring/Hang/Ring
40
Option 28: no Delay from Keychain Touchpad
41
Option 29: Panel Piezo Alarms
41
Option 30: Panel Panic Alarms
42
Option 31: Downloader Enable
42
Option 32: 300 Baud
42
Option 33: Audio Verification
43
Option 34: Fail to Open Report
43
Option 35: Fail to Close Report
43
Option 36: Sensor Activated Light Lockout Start Time
44
Option 37: Sensor Activated Light Lockout Stop Time
44
Option 38: Auto Arm
45
Option 39: Siren Timeout
45
Option 40: Trouble Beeps
46
Option 41: Chime Voice
46
Option 42: Speaker Level
46
Option 43: Numeric Pager/Voice Event Notification Phone Number
47
Option 44: Numeric Pager/Voice Event Notification Phone 3 Reports
47
Option 45: Sensor Alarm Restoral Report
48
Option 46: Fire Shutdown - AVM
48
Option 47: AVM Mode
49
Option 48: Panic Talk - AVM
49
Option 49: Arming Leds Shutdown
49
Option 50: RF Jam Detect
50
Option 51: 24 Hour Sensor Tamper
50
Option 52: Unvacated Premises
50
Option 53: Hardwire Siren Supervision
51
Option 54: Access Code Length
51
Option 55: Status Beep Volume
52
Option 56: Call Waiting
52
Option 57: Supervisory/Tamper Report
52
Option 58: Remote Touchpad Arming
53
Option 59: Exit Extension
53
Option 60: Secure Arming
53
Option 61: Demo Mode
54
Option 62: Supervisory Protest
54
Option 63: 24 Hour Time
54
Option 64: no Arm on Panel Low Battery
55
Option 65: no Usage Report
55
Option 66: External Siren Delay
55
Option 67: Quick Exit
56
Option 68: Swinger Shutdown
56
Option 69: SIA Limits
56
Option 70: Not Available
57
Option 71: Programming Report
57
Option 72: Supervisory Time
57
Option 73: Modem Sensitivity
58
Option 74: Silent Panel Police Panic
58
Option 75: VOX MIC Gain
58
Panel Police Panic
58
Option 76: VOX Gain Range
59
Option 77: Manual MIC Gain
59
Option 78: VOX Receiver Gain
59
Option 79: Panel Cover Tamper
60
Option 80: Alarm Report Verification
60
Option 81: Heating Set Point
60
Option 82: Cooling Set Point
61
Option 83: X10/RF Light Control
61
Option 84: European Compliance
61
Option 85: Smoke Supervision
61
Option 86: Fire Alarm Verify
62
Option 87: 2-Way RF Touchpad Voice
62
Option 88: Custom Defaults
62
Option 89: Serial Port Protocol
62
Option 90: Comm Channel 1 Reports
63
Option 91: Comm Channel 2 Reports
63
Option 92: Comm Channel 3 Reports
63
Option 93: DTIM Reports Phone 1
64
Option 94: DTIM Reports Phone 2
64
Option 95: Not Available
64
Option 96: HWIN2 Output Function
65
Option 97: HWIN1 Output Function
65
Programming System Access Codes
65
Testing the System
66
Control Panel
66
Sensor Testing
67
Improving Sensor/Panel Communication
69
Antenna
69
If a Sensor Fails the Sensor Test
69
Phone Communication
69
Off-Site Phone Operation
70
Central Station Communication
70
Dialog Telephone Interface Module (DTIM)
71
Pager Communication
71
2-Way Voice Operation
72
Voice Event Notification
73
RF Thermostat Operation
73
Personal Help Button
73
X10 Operation
73
Manual Lamp Module Control
73
X10 Siren and Lamp Module Functions
74
Emergency Planning
74
Appendix A
76
Appendix A: Troubleshooting
76
System Status
76
Control Panel
76
Options (Programmable by the Homeowner)
76
Sensors
76
X10 Modules
77
Appendix B: System Configuration
78
Alphabetical Listing of Sensor Names
78
Cross-Zoning
80
System Access Codes
81
Option Settings
81
Utility Access Code 1
81
Master Code
81
Access Codes
81
Panic Code
81
Appendix C: Software Release Notes
85
Software Version 4.0
85
Dialog Telephone Interface Module (DTIM)
85
Ethernet Interface Module
85
Option Changes
85
New Options
85
Specifications
86
Quick Reference Table
88
Advertisement
GE Security Simon 600-1012 User Manual (40 pages)
Simon Security System User Guide
Brand:
GE
| Category:
Security System
| Size: 0.53 MB
Table of Contents
User Guide
1
Table of Contents
5
Introduction to Your Security System
9
Security System Components
9
How You Communicate to Your System
10
Control Panel
10
Remote Handheld Touchpad
10
Dialog QS 1500 Touchtalk Interactive Keypad
10
Keychain Touchpad
11
Telephone
11
Computer
11
How to Use Your Control Panel
11
Home Security
11
Arm
11
Disarm
11
System Status
11
Exit Delay
11
Entry Delay
12
Quick Exit
12
Latchkey
12
Subdisarm
12
Code
13
Home Control
14
Chime Doors
14
Chime Special Motion
14
Direct Bypassing
14
Direct Unbypassing
14
Time Activated Lights
14
Sensor Activated Lights
15
Controlling Individual Lights
15
All Lights on
15
All Lights off
15
Silent Exit
15
Emergency
16
How Your System Communicates to You
16
Panel Voice Messages
16
Status Beeps
16
Alarm Sirens and Lamp Modules
17
Panel Indicator Lights
17
Numeric Pager
17
Dialog QS 1500 Touchtalk Interactive Keypad
18
Canceling and Preventing Accidental Alarms
18
Canceling Accidental Alarms
18
Guidelines for Preventing Accidental Alarms
18
How to Use an Off-Site Phone
19
Using Touchpads and Keypads
19
Touchpads and Keypads
19
System Status
19
ARM Doors & Windows
19
ARM Motion Sensors
20
Disarm
20
Subdisarm
20
Lights
20
Emergency
20
Keychain Touchpad
20
Using a Computer
21
RF Thermostat Operation
21
Programming Your System
21
Programming Instructions
22
Access Codes
23
Light Control
24
House Code
24
Unit Number
24
Programming Options
24
Option 01 - Status Beeps
25
Programming Options
25
Option 02 - Panel Voice
25
Option 03 - Latchkey Time
26
Option 36 and 37- Sensor Activated Light Lockout Start and Stop Times
26
Option 36: Sensor Activated Light Lockout Start Time
26
Option 37: Sensor Activated Light Lockout Stop Time
27
Option 41 - Voice Chime
27
Option 42 - Speaker Level
28
Option 43 - Pager/Voice Event Notification Phone Number
28
Option 55: Status Sounds
29
Option 81: Heating Set Point
30
Option 82: Cooling Set Point
30
Trouble Beeps
31
AC Power Failure
31
System Battery Failure
31
Restoration of Power
31
Sensor Failure
32
Sensor Low Battery
32
Fail-To-Communicate
32
Sensor Open
32
Sensor Tampered
32
Option 50 Detected
32
Siren 1 or 2 Failure
32
System Access Alarm
32
Testing
33
Testing Sensors
33
Testing Communication
34
Setting the Clock
34
Alarm System Limitations
34
Service
35
Planning for Emergencies
35
Emergency Planning
35
Your Floor Plan
36
Access Codes
39
Delay Times
39
Quick Reference Table
40
Advertisement
Related Products
GE Simon 60-910
GE Simon Security System
GE SmartHome Series
GE Security Pro 500
GE Security Pro 60-806
GE Security Pro 1000
GE Security Pro 7000
GE SIMON XT
GE Simon XTi
GE SimpliNano
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL