hit counter script

Advertisement

Operating and installation instructions
Cooker hood
DA 396-5
DA 399-5
DA 399-5 EXT
en - GB
To avoid the risk of accidents
or damage to this appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 09 200 410

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 396-5

  • Page 1 Operating and installation instructions Cooker hood DA 396-5 DA 399-5 DA 399-5 EXT en - GB To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and should be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is not supported by requirements. Inappropriate use the manufacturer and could be can, however, lead to personal injury dangerous. Miele cannot be held liable and damage to property. for damage resulting from incorrect or improper use or operation.
  • Page 5: Technical Safety

    Faulty components must only be the appliance could be damaged. replaced by genuine Miele original Consult a qualified electrician if in any parts. The manufacturer can only doubt. guarantee the safety of the appliance...
  • Page 6 These models may only be combined with a Miele external motor. This appliance must not be used in a non-stationary location (e.g. on a Great care should be taken when ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heating appliance are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Do not use the cooker hood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the cooker hood. To avoid the danger into the appliance and hindering its of fire, do not flambé...
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 Guide to the appliance Telescopic extension piece Tower Canopy Touch controls Grease filters Recirculation grille (only for recirculation mode) Hob lighting Charcoal filter (special accessory for recirculation mode) On/Off control for the fan Controls to select fan power level On/Off control for hob lighting...
  • Page 12: Modes Of Operation

    Modes of operation . . . air recirculation: The cooker hood works with (this requires an optional conversion kit and charcoal filter: see "Technical Data") . . . air extraction: The air is drawn in and cleaned first by The air is drawn in and cleaned by the the grease filters and then by a grease filters and directed outside.
  • Page 13: Operation

    Operation To switch the fan on s Automatic switch-off of the Intensive setting ^ Press the On/Off control s. You can set the Intensive setting so that The fan will come on at power level lI. it only runs for 10 minutes before reverting automatically to level III.
  • Page 14: Hob Lighting I

    Operation To switch the fan off s ^ Press the On/Off control s to switch the fan off. The s symbol goes out. It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the air, whether you are using air extraction or recirculation mode.
  • Page 15: Cleaning And Care

    Cleaning and care A range of Miele branded cleaning and Do not use: conditioning products is available to – cleaning agents containing soda, order from Miele (see back page for acids, chlorides or solvents, details) or the via the internet at www.miele-shop.com.
  • Page 16: Grease Filters

    Cleaning and care Grease filters Controls The re-usable metal grease filters in the The controls may suffer appliance remove solid particles discolouration or damage if soiling is (grease, dust, etc.) from the kitchen left on them for too long. vapours, preventing soiling of the Remove soiling straight away.
  • Page 17 ^ Do not wash at more than 65° C. If a Miele dishwasher is being used, select the Sensor wash programme. ^ Use a mild dishwasher detergent. Depending on the cleaning agent...
  • Page 18: Fitting And Replacing The Charcoal Filter

    It is fitted in the canopy above the household waste. grease filters. New charcoal filters can be purchased from your Miele dealer, from the Miele Spare Parts Department or via the internet at www.miele.shop.com. See back cover for contact details, and "Technical data"...
  • Page 19: Changing A Halogen Lamp

    Cleaning and care ^ First remove the grease filters from Changing a halogen lamp the cooker hood. ^ Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Exercise caution when changing halogen lamps. They get very hot during use and remain hot for some time after being switched off.
  • Page 20: Appliance Dimensions

    Appliance dimensions The diagram is not drawn to scale.
  • Page 21: Safety Distance Between Hob And Cooker Hood (S)

    Connection for air extraction If this cooker hood is installed above C 150 mm, or C 125 mm with reducing a Miele Wok CS 1028 CombiSet collar. appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood.
  • Page 22 Appliance dimensions – Please be aware that if positioned Drilling diagram too high, extraction will be inefficient. – If you want the top of the cooker hood telescopic extension piece to be mounted flush with the ceiling, make sure there is adequate space below the appliance for working.
  • Page 23: Installation

    Installation Dismantling Before installation, it is important to Should the appliance ever need to be read the information given on the dismantled, follow the installation following pages as well as the instructions in reverse order as "Appliance dimensions" and the described on the installation sheet.
  • Page 24: Assembly Parts

    Installation Assembly parts...
  • Page 25 Installation 3 protective sheets for use when fitting the tower. 1 exhaust connection for exhaust 8 screws 5 x 40 mm and ducting C 150 mm. 8 x S 8 plugs for securing the retaining plates to the wall. 1 reducing collar for exhaust ducting C 125 mm.
  • Page 26: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety it is advisable to protect and local safety regulations the appliance with a suitable residual...
  • Page 27: Connection For Air Extraction

    Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the cooker hood at the same time as...
  • Page 28: Condensate Trap

    Connection for air extraction Condensate trap – If the exhaust air is to be ducted into the open air, the installation of a (optional accessory) telescopic wall vent or roof vent (available as an optional accessory) is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
  • Page 29: Silencer

    Connection for air extraction Silencer ...with air extraction: (optional accessory) The silencer not only reduces noise from the motor outside the house, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to the ducting exit ...in recirculation mode: The silencer needs to be positioned...
  • Page 30: Operation With Control Module Dsm 400

    Operation with Control module DSM 400 The Miele DSM 400 control module can Components used in the central be used to combine the cooker hood ducting system are not supplied by with other components. Miele. It enables the following: If in any doubt, the advice of a...
  • Page 31: After Sales Service

    For information on the appliance under guarantee, please contact: guarantee specific to your country – Your Miele Dealer / Chartered Agent please contact Miele. See back cover for contact details. In the U.K. your appliance is –...
  • Page 32: Technical Data

    Weight Optional extra for recirculation DA 396-5 ....21.6 kg mode: DA 399-5 ....24.6 kg - Conversion Kit DUW 20 DA 399-5 EXT .
  • Page 36 Alteration rights reserved / 3011 M.-Nr. 09 200 410 / 00...

Table of Contents