Temperature modulated with electronic ignition suitable for heating potable water - not approved for space heating purposes intended for variable flow applications
Hide thumbs Also See for GWH C 800 ES:
Table of Contents

Advertisement

Installation instructions
Recommended exhaust vent terminator position
Fig. 36
Ref.
Description
Directly below an opening; operable windows, doors and any non-
A
mechanical fresh air openings
Below a gutter, sanitary pipework or eaves
B
Below a gutter, sanitary pipework or eaves, protected by metal
shielding
C
From any internal corner
Above ground or snow pack
D*
Above a paved sidewalk
From an opposing wall or structure facing the termination
E
From the relief valve of a Ip gas regulator
F
From a terminator facing a terminator
G
Vertically between two exhaust vent terminators on the same wall
H
Horizontally between two exhaust vent terminators on the same wall
Horizontally from combustion air inlet of a twin pipe system
I**
From the gravity combustion air inlet any other equipment
J
From any external corner
Horizontally from an opening; operable windows, doors and any non-
K
mechanical fresh air openings
Vertically from a wall, roof slope, or obstruction (venting through a flat
L
or pitched roof)
Table 10
* Subject to local codes and anticipated snow level
** Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions
NOTE: terminating exhaust vent under a deck is not permitted
24
Minimum distance
36 in (twin pipe installation)
48 in (single pipe installation)
24 in
12 in
12 in
12 in
7 ft
24 in
60 in
48 in
60 in
3 ft
3 ft
48 in
12 in
12 in (twin pipe installation)
48 in (single pipe installation)
see ABOVE THE ROOF