Contents 1 About Your System........................9 ....................9 Front-Panel Features And Indicators—Tower Mode ....................14 Front-Panel Features And Indicators—Rack Mode ..............................15 LCD Panel Features ..............................16 Home Screen ..............................16 Setup Menu ............................... 17 View Menu ..............................17 Diagnostic Indicators ..........................19 Hard-Drive Indicator Patterns ........................
Page 4
........................... 38 Entering The UEFI Boot Manager ...................... 39 Using The Boot Manager Navigation Keys ............................39 Boot Manager Screen ............................... 40 UEFI Boot Menu ..........................40 Embedded System Management ..............................40 iDRAC Settings Utility ........................40 Entering The iDRAC Settings Utility ........................40 Changing The Thermal Settings 3 Installing System Components....................43 ..............................
Page 5
......................62 Removing The Internal Hard-Drive Bay ......................63 Installing The Internal Hard-Drive Bay ........................63 Removing A Cabled Hard Drive ......................... 64 Installing A Cabled Hard Drive ............................65 Hard-Drive Backplane ......................65 Removing The Hard-Drive Backplane ....................... 71 Installing The Hard-Drive Backplane .............................72 Four-Slot Hard-Drive Blank ......................72...
Page 6
..........................96 Installing An Internal SD Card ................................97 Processors .............................97 Removing A Processor ............................99 Installing A Processor ..........................100 Redundant AC Power Supply .....................100 Removing A Redundant AC Power Supply ...................... 101 Installing A Redundant AC Power Supply ....................... 102 Removing The Power Supply Blank ........................
Page 7
Troubleshooting Expansion Cards ..........................137 Troubleshooting Processor 6 Using System Diagnostics..................... 139 ............................139 Dell Online Diagnostics ........................139 Dell Embedded System Diagnostics ..................139 When To Use The Embedded System Diagnostics ....................139 Running The Embedded System Diagnostics ........................... 140 System Diagnostic Controls 7 Jumpers And Connectors......................
About Your System Front-Panel Features And Indicators—Tower Mode Figure 1. Front-Panel Features and Indicators—2.5 Inch Hot-Swappable Hard-Drive Chassis...
Page 10
Figure 2. Front-Panel Features and Indicators—3.5 Inch Hot-Swappable Hard-Drive Chassis Item Indicator, Button, or Icon Description Connector Tape drive (optional) One optional 5.25 inch tape drive. NOTE: If your system is installed with a double-width GPU card, the system supports only one 5.25 inch removable media storage device.
Page 11
If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter BIOS progress mode. To reset integrated Dell Remote Access Controller (iDRAC) (if not disabled in F2 iDRAC setup), press and hold for more than 15 seconds.
Page 12
Item Indicator, Button, or Icon Description Connector • Up to sixteen 2.5 inch hot-swappable hard drives Figure 3. Front-Panel Features and Indicators—3.5 Inch Cabled Hard-Drive Chassis NOTE: Cabled hard-drive systems are not rackable. Item Indicator, Button, or Icon Description Connector Tape drive (optional) One optional 5.25 inch tape drive.
Page 13
Item Indicator, Button, or Icon Description Connector Power-on indicator, power The power-on indicator lights when the system power is button on. The power button controls the power supply output to the system. NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.
Front-Panel Features And Indicators—Rack Mode Figure 4. Front-Panel Features and Indicators NOTE: Only systems with hot-swappable hard drives are rackable. Item Indicator, Button, or Icon Description Connector Power-on indicator, power The power-on indicator lights when the system power is button on.
Item Indicator, Button, or Icon Description Connector LCD menu buttons Allow you to navigate the control panel LCD menu. Information tag A slide-out label panel which allows you to record system information such as Service Tag, NIC, MAC address, and so on.
• The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools. Figure 5. LCD Panel Features Item Button Description Left Moves the cursor back in one-step increments. Select Selects the menu item highlighted by the cursor. Right Moves the cursor forward in one-step increments.
Option Description Select Simple to display LCD error messages in a simplified user-friendly description. See System Error Messages for a list of messages in this format. Set home Select the default information to be displayed on the LCD Home screen. See View Menu to see the options and option items that can be set as the default on the Home screen.
Page 18
Health Indicator Condition Corrective Action (for example, a failed fan or hard drive) Hard-drive Indicator Condition Corrective Action The indicator lights None required. green to indicate hard-drive activity. Electrical Indicator Condition Corrective Action The indicator blinks See the System Event Log or system messages for the specific issue. amber if the system If it is due to a problem with the power supply, check the LED on the experiences an...
Memory Indicator Condition Corrective Action The indicator blinks See the system event log or system messages for the location of the amber if a memory failed memory. Reinstall the memory device. If the problem persists, error occurs. Getting Help. PCIe Indicator Condition Corrective Action The indicator blinks...
Page 20
Drive-Status Condition Indicator Pattern (RAID Only) NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time. Blinks green, amber, Predicted drive failure and off Blinks amber four Drive failed...
Back-Panel Features And Indicators Figure 7. Back-Panel Features and Indicators Item Indicator, Button, or Icon Description Connector Power supplies (PSU1 and Redundant power Up to two 495 W or 750 W AC PSU2) supply redundant power supplies. Non-redundant One 350 W non-redundant AC power supply power supply.
Page 22
Item Indicator, Button, or Icon Description Connector NOTE: Non-redundant power supply is supported in systems with cabled hard drives and systems with an x8 backplane. PCIe expansion card slots Allow you to connect up to five full-height PCIe expansion cards. vFlash media card slot Allows you to insert a vFlash media card.
NIC Indicator Codes Figure 8. NIC Indicator 1. link indicator 2. activity indicator Indicator Indicator Code Link and activity The NIC is not connected to the network. indicators are off Link indicator is The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps). green Link indicator is The NIC is connected to a valid network at less than its maximum port speed.
Power Indicator Condition Pattern Not lit Power is not connected. Green A valid power source is connected to the power supply and the power supply is operational. Flashing amber Indicates a problem with the power supply. CAUTION: When correcting a power supply mismatch, replace only the power supply with the flashing indicator.
• For the full name of an abbreviation or acronym used in this document, see the Glossary at www.dell.com/ support/manuals. NOTE: Always check for updates on www.dell.com/support/manuals and read the updates first because they often...
The exact LC2 feature set is determined by the iDRAC license purchased. For more information, see the Dell LC2 documentation. Enters the BIOS Boot Manager or the Unified Extensible <F11>...
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot mode. NOTE: For the latest information on supported operating systems, go to dell.com/ossupport. Entering System Setup Turn on or restart your system.
System Setup Options System Setup Main Screen NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings. Menu Item Description System BIOS This option is used to view and configure BIOS settings. iDRAC Settings This option is used to view and configure iDRAC settings. Device Settings This option is used to view and configure device settings.
Mode configuration of your system are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode. NOTE: The Memory Operating Mode can have different defaults and available options based on the memory configuration.
Page 31
Menu Item Description NOTE: The QPI speed option displays only when both the processors are installed. Alternate RTID Allows you to allocate more RTIDs to the remote socket increasing cache performance (Requestor between the sockets or work in normal mode for NUMA. By default, the Alternate RTID Transaction ID) (Requestor Transaction ID) Setting is set to Disabled.
SATA Settings Screen Menu Item Description Embedded SATA Allows the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option is set to AHCI. Port A Auto enables BIOS support for the device attached to SATA port A. Off disables BIOS support for the device.
Integrated Devices Screen Menu Item Description User Accessible USB Allows you enable or disable the user accessible USB ports. Selecting Only Back Ports On Ports disables the front USB ports and selecting All Ports Off disables both front and back USB ports. By default, the User Accessible USB Ports option is set to All Ports On.
Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller. NOTE: The following parameters are available only when the System Profile is set to Custom.
Menu Item Description NOTE: When C States is enabled in Custom mode, changing the Monitor/Mwait setting does not impact system power/performance. Memory Patrol Scrub Allows you to set the memory patrol scrub frequency. By default, the Memory Patrol Scrub option is set to Standard. Memory Refresh Rate Allows you to set the memory refresh rate.
Menu Item Description NMI Button Allows you to enable or disable the NMI button on the front of the system. By default, the NMI Button option is set to Disabled. AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last.
Assigning A System And/Or Setup Password NOTE: The password jumper enables or disables the System Password and Setup Password features. For more information on the password jumper settings, see System Board Jumper Settings. You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup Password only when the password jumper setting is enabled and Password Status is Unlocked.
In the System Security screen, verify that Password Status is Unlocked. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>. NOTE: If you change the System and/or Setup password a message prompts you to re-enter the new password.
Displays a list of the drivers installed on the system and their health status. Launch System Setup Enables you to access the System Setup. System Utilities Enables you to access the BIOS Update File Explorer, run the Dell Diagnostics program, and reboot the system.
Sets a one-time boot option not included in the boot option list. Embedded System Management The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle. The Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.
Page 41
NOTE: When the User Option is set to the default Auto setting, the user option cannot be modified. 3. Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields. 4. Click Back → Finish → Yes.
Installing System Components Recommended Tools You may need the following items to perform the procedures in this section: • Key to the system keylock • #1 and #2 Phillips screwdrivers • Wrist grounding strap connected to ground Front Bezel (Optional) Installing The Front Bezel Insert the bezel tabs into the bezel tab slots in the chassis.
Figure 11. Removing and Installing the Front Bezel 1. system 2. front bezel 3. keylock 4. release latch Removing The Front Bezel Insert the bezel key in the keylock. Keeping the keylock pressed with the bezel key, rotate the keylock to the unlocked position. Press down on the release latch at the top of the bezel.
Removing The System Feet NOTE: It is recommended that you remove the system feet only when you are converting the system from the tower mode to the rack mode, or when you are replacing the system feet with the wheel assembly. Rotate the system feet inward.
• Wheel assembly units (front and back) • Two screws for the wheel assembly units • Support unit with two screws Removing The Wheel Assembly Lay the system on a sturdy, stable surface with the wheel assembly extending off the edge of the surface. Remove the two screws securing the support unit to the base of the chassis and pull out the support unit.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 49
NOTE: Components that are hot-swappable are marked orange and touch-points on the components are marked blue. Figure 15. Inside the System—Hot-Swappable Hard Drives 1. power interposer board 6. system feet (4) 2. PCIe card holder (optional) 7. expansion card slots (5) 3.
NOTE: If your system is installed with a double-width GPU card, the system supports only one 5.25 inch removal media storage. NOTE: An optical drive may be replaced by a Dell PowerVault RD1000 removable media device. For systems with hot-swappable hard drives, the optical and tape drives can be configured as follows:...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 52
Figure 17. Removing and Installing the Optical Drive or Tape Drive 1. optical drive 2. tape drive 3. release latch...
Page 53
Figure 18. Cabling—Optical Drive and Tape Drive 1. connector for power cable extension 7. optical drive2 power connector 2. mini-SAS connector on PERC card 8. optical drive2 data connector 3. ODD2/TBU connector on system board 9. optical drive1 power connector 4.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes. NOTE: For proper seating of the cooling shroud in the system chassis, ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing clips. Align the two slots on the cooling shroud with the tabs on the internal cooling fan.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Removing A 2.5 Inch Hard-Drive Blank CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks installed. If installed, remove the front bezel. Press the release button and slide the hard-drive blank out until it is free of the hard-drive slot. Figure 21.
Figure 22. Removing and Installing a 3.5 Inch Hard-Drive Blank 1. hard-drive blank 2. release button Installing A 3.5 Inch Hard-Drive Blank If installed, remove the front bezel. Insert the hard-drive blank into the hard-drive slot until the release button clicks into place. If applicable, install the front bezel.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 67
Figure 29. Connectors on an x8 Hard-Drive Backplane 1. SAS B connector 4. SAS A connector 2. power connector for optical drive and tape 5. I2C connector drive 3. backplane power connector...
Page 68
Figure 30. Cabling—x8 Hard-Drive Backplane 1. power connector 5. SAS A connector on backplane 2. SAS A connector on system board 6. backplane power connector 3. I2C connector on system board 4. I2C connector on backplane...
Page 70
Figure 32. Connectors on an x16 Hard-Drive Backplane 1. backplane power connector 5. primary SAS connectors (A and B) 2. backplane 6. secondary SAS connectors (A1 and B1) 3. power connector for optical drive and tape drive 4. I2C connector...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Close the system. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. If applicable, install the front bezel. Four-Slot Hard-Drive Blank Systems with x8 hard-drive backplanes configured for software RAID support only four hard drives.
Figure 34. Installing and Removing the Four-Slot Hard-Drive Blank 1. four-slot hard-drive blank 2. release tab 3. screwdriver Installing A Four-Slot Hard-Drive Blank Locate the hard drive slots numbered from four to seven. Insert the four-slot hard-drive blank into the hard-drive slot, and push it until the release tabs click into place. Close the system.
Page 74
• number of DIMMs populated per channel • DIMM operating voltage • system profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized) • maximum supported DIMM frequency of the processor The system contains six memory sockets organized into three channels. In each channel, the release levers of the first socket are marked white and the second socket black.
DIMM Type DIMMs Operating Frequency (in MT/s) Maximum DIMM Rank/ Populated/ Channel Channel 1.5 V 1.35 V 1333, 1066, and 800 1333, 1066, and 800 Dual rank RDIMM 1333, 1066, and 800 1066 and 800 Quad rank 1600, 1333, 1066, and 800 1333, 1066, and 800 Dual rank 1066 and 800...
NOTE: Advanced ECC with Mirroring is not supported. Memory Optimized (Independent Channel) Mode This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot population requirements. Memory Sparing NOTE: To use memory sparing, this feature must be enabled in the System Setup. In this mode, one rank per channel is reserved as a spare.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 79
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. Open the system.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 81
Figure 39. Removing and Installing the Internal Cooling Fan 1. arrow 2. internal cooling fan 3. internal cooling fan power cable 4. release tab Figure 40. Cabling—Internal Cooling Fan 1. FAN1 power connector on system board 3. securing clip on system board 2.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 83
11. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward. 12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Figure 41. Removing and Installing the External Cooling Fan 1.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 98
Figure 50. Removing and Installing the Heat Sink 1. heat sink 2. captive screws (4) 3. processor shield 4. standoffs (4) CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped. 11.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Connect the power cable to the power supply and plug the cable into a power outlet. CAUTION: When connecting the power cable, secure the cable with the cable strap. NOTE: When installing, hot-swapping, or hot-adding a new power supply, allow several seconds for the system to recognize the power supply and determine its status.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 105
Figure 55. Removing and Installing a Non-Redundant AC Power Supply 1. screw 6. P2 cable connector 2. power supply unit cage 7. P3 cable connector 3. non-redundant power supply 8. backplane connector 4. standoff on the chassis 5. P1 cable connector...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 107
Figure 56. Removing and Installing the Power Interposer Board and the Power Distribution Board 1. power distribution board 8. P1 cable connector 2. slots on power interposer board (4) 9. P2 cable connector 3. GPU power connector 10. P3 cable connector 4.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable surface with the wheel assembly extending off the edge of the surface. Open the system. Locate the battery socket. CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 111
3. control-panel assembly cable connector 6. control panel 4. screw 5. control-panel assembly Figure 59. Removing and Installing the Control-Panel Assembly With Diagnostic Indicators in a Tower-Mode System 1. control panel board 2. control-panel assembly connector 3. control-panel assembly cable connector 4.
Page 112
Figure 60. Removing and Installing the Control-Panel Assembly in a Rack-Mode System 1. LCD module ZIF connector 6. screw 2. VGA module connector 7. control-panel board 3. VGA module cable connector 8. VGA module 4. control-panel assembly connector 9. control panel for rack mode 5.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 114
Figure 62. Removing and Installing the Control Panel for Systems With an LCD Module 1. control panel 4. control-panel assembly 2. control-panel board 5. tabs (3) 3. LCD module Figure 63. Removing and Installing the Control Panel for Systems With Diagnostic Indicators 1.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 123
If applicable, place the system upright on a flat, stable surface and rotate the system feet outward. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. iDRAC7 User's Guide , at 10. Import your new or existing iDRAC Enterprise license. For more information, see support.dell.com/manuals.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 126
Open the system. Remove the system top cover by following the steps below: a) Using a #2 Phillips screwdriver, remove the three screws on the side of the system that secure the system top cover to the system chassis. b) Slide the top panel toward the back of the system until the panel hooks clear the chassis slots. c) Rotate the free side of the panel outward about 15 degrees and pull the panel clear of the system.
Figure 70. Removing and Installing the Rack Ears 1. front panel 2. rack ears (2) 3. screws for each rack ear (3) 12. Close the system. Rack Installation To install the system in a rack, see the system’s Rack Installation Guide.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Power down all attached USB devices and disconnect them from the system. Restart the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options. If your keyboard is not functioning, you can also use remote access.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Dell Online Diagnostics Dell Online Diagnostics, a stand-alone suite of diagnostic programs or test modules, allows you to run diagnostic tests on the systems in a production environment, and helps you ensure maximum uptime of your systems. Online Diagnostics allows you to run diagnostic tests on chassis and storage components such as hard drives, physical memory, and network interface cards (NICs).
Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded. Dell Enhanced Pre-boot System Assessment User Guide at For information about embedded system diagnostics, see the...
Jumpers And Connectors System Board Jumper Settings For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password. Table 4. System Board Jumper Settings Jumper Setting Description PWRD_EN The password feature is enabled (pins 2–4). (default) The password feature is disabled (pins 4–6).
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 144
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables the new password(s) the next time it boots. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
Technical Specifications Processor Processor type • One Intel Xeon processor E5-2400 product family, • One Intel Xeon processor E5-1410, or • One Intel Pentium processor 1400 Expansion Bus Bus type PCI Express Generation 3 and 2 Expansion slots (Slot 1) One full-height, half-length x4 PCIe Gen2 card slot connected to Platform Controller Hub (PCH) (Slot 2) One full-height, full-length x1 PCIe Gen2 card slot connected to PCH...
Page 146
Memory Maximum RAM RDIMMs 96 GB UDIMMs 24 GB Drives Hard drives Four hard-drive systems Up to four 3.5 inch, internal, cabled SATA, nearline SAS, or SAS hard drives. Eight hard-drive systems Up to eight 3.5 inch, internal, hot-swappable SATA, nearline SAS, SAS hard drives.
Page 147
The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft). • GPU is not supported. • Non-redundant power supplies are not supported. • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
Page 148
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Maximum Temperature Gradient (Operating and 20 °C/h (36 °F/h) Storage) Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F) Temperature (Continuous Operation) Temperature Ranges (for altitude less than 950 m or 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on...
Page 149
Environmental NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures.
System Messages LCD Messages NOTE: Applicable only if your system has an LCD display. The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.
Page 152
Error Code Message Information AMP0302 name > current is greater than the upper warning Message The system board < threshold. name > current is outside of the optimum range. Details System board < Action 1. Review system power policy. 2. Check system logs for power related failures. 3.
Page 153
Error Code Message Information ASR0003 Message The watchdog timer power cycled the system. Details The operating system or an application failed to communicate within the time-out period. The system was power-cycled. Action Check the operating system, application, hardware, and system event log for exception events.
Page 154
Error Code Message Information Action Review the technical specifications for supported processor types. CPU0010 number > is throttled. Message CPU < Details The CPU is throttled due to thermal or power conditions. Action Review system logs for power or thermal exceptions. CPU0023 number >...
Page 155
Error Code Message Information 2. Turn off the system and remove input power for one minute. 3. Ensure the processor is seated correctly. 4. Reapply input power and turn on the system. 5. If the issue persists, see Getting Help. CPU0702 Message CPU bus parity error detected.
Page 156
Error Code Message Information 5. If the issue persists, see Getting Help. FAN0000 number > RPM is less than the lower warning threshold. Message Fan < Details Fan operating speed is out of range. Action Remove and reinstall the fan. If the issue persists, see Getting Help.
Page 157
Error Code Message Information Action Check if the cable is present, then reinstall or reconnect. MEM0000 Message Persistent correctable memory errors detected on a memory device location >. at location(s) < Details This is an early indicator of a possible future uncorrectable error. Action Re-seat the memory modules.
Page 158
Error Code Message Information location >. Power cycle system. LCD Message Memory mirror lost on < Details The memory may not be seated correctly, misconfigured, or has failed. Action Check the memory configuration. Re-seat the memory modules. If the issue persists, see Getting Help.
Page 159
Error Code Message Information Action Cycle input power, update component drivers, if device is removable, reinstall the device. PCI1320 Message A bus fatal error was detected on a component at bus bus >device< device >function < func >. < bus > device < device > function < func >. Power LCD Message Bus fatal error on bus <...
Page 160
Error Code Message Information number > removed from disk drive bay < bay >. Check drive. LCD Message Drive < Details The controller detected that the drive was removed. Action Verify drive installation. Re-seat the failed drive. If the issue persists, Getting Help.
Page 161
Error Code Message Information PSU0006 number > type mismatch. Message Power supply < LCD Message Power supply < number > is incorrectly configured. Check PSU. Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review proper configuration in this manual.
Page 162
Error Code Message Information PSU0034 number >. Message An under voltage fault detected on power supply < LCD Message An under voltage fault detected on PSU < number >. Check power source. Details This failure may be the result of an electrical issue with cables or subsystem components in the system.
Page 163
Error Code Message Information PSU1201 Message Power supply redundancy is lost. Details The power supply tries to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Check input power. Reinstall the power supply. If the issue persists, Getting Help.
Page 164
Error Code Message Information Details An error was reported during a SD card read or write. Action Reseat the flash media. If the problem persists, see Getting Help. RFM1014 name > is write protected. Message Removable Flash Media < name > is write protected. Check SD Card. LCD Message Removable Flash Media <...
Page 165
Error Code Message Information SEC0031 Message The chassis is open while the power is on. LCD Message Intrusion detected. Check chassis cover. Details The chassis is open. System performance may be degraded, and security may be compromised. Action Close the chassis. Check system logs. SEC0033 Message The chassis is open while the power is off.
Page 166
Error Code Message Information Action Re-configure system to the minimum supported configuration. If issues persists, contact support. TMP0118 Message The system inlet temperature is less than the lower warning threshold. LCD Message System inlet temperature is outside of range. Details Ambient air temperature is too cool.
Error Code Message Information Action 1. Review system logs for power supply exceptions. 2. Re-configure the system to minimum configuration, inspect and reinstall system cables. 3. If the issue persists, see Getting Help. Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive.
Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: Visit dell.com/support...