DINION 5100i IR Table of contents | en Table of contents Browser connection System requirements Establishing the connection Password protection in camera System overview Live Playback Configuration Dashboard Operation via the browser Live page Playback page 3.2.1 Selecting the recording stream 3.2.2...
Page 4
| Table of contents DINION 5100i IR 4.5.3 Maximum Retention Time 4.5.4 Recording Scheduler 4.5.5 Recording Status 4.5.6 Recording Statistics 4.5.7 Image Posting 4.5.8 SD Card Status Alarm 4.6.1 Alarm Connections 4.6.2 4.6.3 Audio Alarm 4.6.4 Alarm email 4.6.5 Alarm Inputs 4.6.6...
If you cannot connect, the unit may have reached its maximum number of connections. Depending on the device and network configuration, each unit can have up to 50 web browser connections, or up to 100 connections via Bosch Video Client or BVMS. Password protection in camera The device is password-protected.
Page 6
| Browser connection DINION 5100i IR – Minimum of 1 special character These special characters are not allowed: '@', '&', '<', '>', ':', '+' When you use Configuration Manager to access your device for the first time, you must set the initial password of the device in Configuration Manager.
Dashboard Click this icon to see detailed system information. Links Click this icon to navigate to the Bosch download store. Logout Click this icon to log out of the device. Click this icon to get context-sensitive help for the page you are browsing.
| System overview DINION 5100i IR Click the Set and Reboot button. The camera reboots and the changed settings are activated. Dashboard The Dashboard page is used to display detailed information about the device. The Dashboard is only visible in the application bar if the Show 'Dashboard' option is enabled by a service-level user in the Configuration ->...
DINION 5100i IR Operation via the browser | en Operation via the browser Live page After the connection is established, the Live page is initially displayed. It shows the live video image on the right of the browser window. Depending on the configuration, various text overlays may be visible on the live video image.
| Operation via the browser DINION 5100i IR When accessing the unit with a browser, the local storage, processor and network status icons are shown in the upper right of the window. When a local storage card is available, the memory card icon changes color (green, orange or red) to indicate the local storage activity.
DINION 5100i IR Operation via the browser | en – Search – Export – Track list 3.2.1 Selecting the recording stream Expand the Connection group on the left side of the browser. To view a recording stream: – Click the Recording drop-down arrow to see the options.
| Operation via the browser DINION 5100i IR – Step forward or backward frame-by-frame when paused (small arrows) Dashboard The Dashboard page shows information on 4 topics: – Device status – Recording status – Connection Status – Services You can also download a .JSON file with information about the device:...
Certificate. A check mark in this check box indicates that at least one certificate is loaded onto the device. The Trusted certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: –...
DINION 5100i IR – It has not been tampered with. The Trusted certificate is issued by Escrypt. Escrypt is a Bosch company and Certificate Authority (CA). – Active Directory server (AD FS). A check mark in this check box indicates that the device uses an active directory server.
DINION 5100i IR Configuration | en Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording. Device time zone Select the time zone in which the system is located. Daylight saving time The internal clock can switch automatically between normal and daylight saving time (DST).
Page 16
| Configuration DINION 5100i IR Show VCA metadata When video content analysis (VCA) is activated, additional information is displayed in the live video stream. With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded are marked with yellow rectangles.
DINION 5100i IR Configuration | en Note: Latency mode is only usable with MPEG-ActiveX in Internet Explorer. This browser is no longer supported. Video buffer The value shown is calculated from the Latency mode setting. It cannot be changed. JPEG resolution Specify the size of the JPEG image on the Live page from the dropdown list.
| Configuration DINION 5100i IR Path for JPEG and video files Enter the path for the storage location of individual images and video sequences saved from the Live page. Video file format Select a file format for the live page display. The MP4 format does not include metadata.
DINION 5100i IR Configuration | en Path Enter an exact path to post the images on the account server. Click Browse... to browse to the required path. Maximum bit rate Enter the maximum bit rate in kbps that will be allowed when communicating with the account.
Page 20
| Configuration DINION 5100i IR To enable High dynamic range: Set Electronic image stabilization to Off. Go to Camera > Enhance and set High dynamic range to On. Some types of light can show flickering in the image when the frame rate is not synchronized with the mains power frequency.
Page 21
DINION 5100i IR Configuration | en – The Live Video window shows a live video stream. Click in the live video window to move the device and center its field of view at the selected position. The device also automatically levels the horizon.
| Configuration DINION 5100i IR Note: Clicking this button also clears the service-level password. Operators must reset the password before doing anything else. 4.4.2 Display Stamping Various overlays or stamps in the video image provide important supplementary information. These overlays can be enabled individually and arranged on the image in a clear manner.
Page 23
DINION 5100i IR Configuration | en Logo stamping – Enable Check this box to enable Logo stamping. – Position (XY) This parameter becomes visible if Logo stamping is enabled. Insert the values for the X and Y coordinates to specify the logo's position.
| Configuration DINION 5100i IR Stream security Select from the Video authentication drop-down box a method for verifying the integrity of the video. If you select Watermarking, all images are marked with an icon. The icon indicates if the sequence (live or saved) has been manipulated.
Page 25
DINION 5100i IR Configuration | en The focal length is determined by the lens. The shorter the focal length, the wider the field of view. The longer the focal length, the narrower the field of view and the higher the magnification.
Page 26
| Configuration DINION 5100i IR – Click to place an angle on the ground in the image. The angle on ground represents an angle lying on the horizontal ground plane, such as the corner of a carpet or parking bay markings.
DINION 5100i IR Configuration | en Latitude Latitude is the north-south position of the camera in the spherical coordinate system WGS 84. Longitude Longitude is the east-west position of the camera in the spherical coordinate system WGS 84. Ground level [m] The elevation of the ground above sea level.
| Configuration DINION 5100i IR Sports and gaming This mode is for high-speed capture, and improved color rendition and sharpness. Retail This mode has improved color rendition and sharpness with reduced bandwidth requirements. Mode ID The name of the selected mode is displayed.
Page 29
DINION 5100i IR Configuration | en Select the appropriate automatic high-level control mode from the drop-down list. – Fluorescent 50 Hz – Fluorescent 60 Hz – Standard ALC level Adjust the video output level. Select the range within which the ALC will operate. A positive value is more useful for low- light conditions;...
| Configuration DINION 5100i IR Notice! The device has a mechanism to prevent oscillation between switching from day to night and night to day continuously when the device is in Auto. In case of frequent oscillations, the device will stay progressively longer in night mode. At a certain point, the device will stop oscillating and enter permanent night mode.
DINION 5100i IR Configuration | en A low (negative) value makes the picture less sharp. Increasing sharpness brings out more detail. Extra sharpness can enhance the details of license plates, facial features and the edges of certain surfaces but will increase bandwidth requirements.
Page 32
The Active profile follows the scheduled profiles under Recording Profiles. Please refer to section Recording Profiles. This behavior is only applicable when using Bosch recording solutions, including edge recording or VRM recording. Third-party recording solutions might use the Non-recording profile.
Page 33
DINION 5100i IR Configuration | en Select the necessary bit rate optimization setting: – Off: bit rate optimization is disabled – Maximum quality – High quality – Medium – Low bit rate – Minimum bit rate Maximum bit rate The encoder does not exceed the maximum bit rate set, which limits the image quality when necessary.
| Configuration DINION 5100i IR Set the value for I/P-frame delta QP to the lowest possible value. This is how to save bandwidth and memory in normal scenes. The image quality is retained even in the case of increased movement since the bandwidth is then filled up to the value that is entered under Maximum bit rate.
DINION 5100i IR Configuration | en The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data is encoded according to the selected format and requires additional bandwidth. If you do not want any audio data to be transmitted, select Off.
| Configuration DINION 5100i IR Ten recording profiles are available where these recording tracks can be defined differently. These profiles are then used for building schedules. A Video Recording Manager (VRM) can control all recording when accessing an iSCSI system.
DINION 5100i IR Configuration | en – Newly added media is shown as Not active in the Status column. Click Set to activate all media in the Managed storage media list. – The Status column shows all media as Online.
Page 38
| Configuration DINION 5100i IR Recording includes Select what is to be included in the recordings: – Audio: If audio is not enabled, Off is shown. Click on Off and the page is redirected to the Audio section. –...
DINION 5100i IR Configuration | en Export to account Select an account from the drop-down box to export to an account. If an account has not yet been defined, click Configure accounts to jump to the Accounts page where the server information can be entered.
| Configuration DINION 5100i IR Recording status The graphic indicates the recording activity. An animated graphic is displayed when recording is taking place. Activating recording After completing configuration, activate the recording schedule and start scheduled recording. Once activated, the Recording Profiles and the Recording Scheduler are deactivated and the configuration cannot be modified.
– A warning through the Video Management System If a SD card is not installed, ‘SD card not found’ is shown. Notice! Bosch recommends the use of industrial micro SD cards with health monitoring. Alarm 4.6.1 Alarm Connections In the event of an alarm, the unit can automatically connect to a pre-defined IP address. The unit can contact up to ten IP addresses in the order listed until a connection is made.
Page 42
| Configuration DINION 5100i IR Destination password If the remote station is password protected, enter the password here. Only ten passwords can be defined here. Define a general password if more than ten connections are required. The unit connects to all remote stations protected by the same general password.
Detection of movement can be used to trigger an alarm and to transmit metadata. Various VCA configurations can be selected and adapted to your application, as required. Configure the VCA setting in the Bosch Configuration Manager. 4.6.3 Audio Alarm Alarms can be generated based on audio signals.
| Configuration DINION 5100i IR SMTP password Enter the required password for the registered user name. Format Select the data format of the alarm message. – Standard (with JPEG): e‑mail with JPEG image file attachment. – SMS: e‑mail in SMS format to an e‑mail‑to‑SMS gateway without an image attachment.
DINION 5100i IR Configuration | en Idle state Select Open for the output to operate as a normally open contact, or select Closed if the output is to operate as a normally closed contact. Operating mode Select the way the output works.
| Configuration DINION 5100i IR 4.7.2 Network Access If the IP address, subnet mask, or gateway address is changed, then the device is only available under the new addresses after the reboot. Supported protocols Select the protocols you want to configure from the dropdown list.
DINION 5100i IR Configuration | en HTTP browser port Select a different HTTP browser port from the list if required. The default HTTP port is 80. To limit connection to HTTPS, deactivate the HTTP port. To do this, activate the Off option.
| Configuration DINION 5100i IR 802.1x Authentication If a RADIUS server is employed in the network for managing access rights, authentication must be activated here to allow communication with the unit. The RADIUS server must also contain the corresponding data.
Page 49
DINION 5100i IR Configuration | en 1. SNMP host address / 2. SNMP host address If you wish to send SNMP traps automatically, enter the IP addresses of one or two required target units here. SNMP v1 legacy When you select SNMP v1 legacy in the field SNMP, the fields Write community and SNMP traps appear.
| Configuration DINION 5100i IR 4.7.5 Multicast The device can enable multiple receivers to receive the video signal simultaneously. The stream is either duplicated and then distributed to multiple receivers (Multi-unicast), or it is sent as a single stream to the network, where it is simultaneously distributed to multiple receivers in a defined group (Multicast).
DINION 5100i IR Configuration | en Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances. Port Enter the port address for the stream here. Audio Enable Enable simultaneous data reception on receivers that need to activate the multicast function.
| Configuration DINION 5100i IR The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transferred to the device via the network. The firmware is installed there automatically. Thus, a camera can be serviced and updated remotely without requiring a technician to make changes to the device on site.
DINION 5100i IR Configuration | en The Installed licenses field lists all licenses currently installed in the device. 4.8.3 Certificates Add a certificate/file to the file list Click Add. In the Add certificate window, select: – Upload certificate to select a file that is available: –...
| Configuration DINION 5100i IR 4.8.5 System Overview This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Select the text on this page with a mouse and copy it so that it can be pasted into an e-mail if required.
DINION 5100i IR Troubleshooting | en Troubleshooting Physical reset button You may need to complete a hardware reset if you have the following issues: – You can power up the camera but cannot log on to the camera using the web browser.
– Repair & Exchange – Product Security Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses, video tutorials and documents: www.boschsecurity.com/xc/en/support/training/ 2023-08 | V01 | F.01U.393.997 Bosch Security Systems B.V. User manual...
Page 57
DINION 5100i IR Appendices | Bosch Security Systems B.V. 2023-08 | V01 | F.01U.393.997 User manual...
Page 58
| Appendices DINION 5100i IR 2023-08 | V01 | F.01U.393.997 Bosch Security Systems B.V. User manual...