Contents Chapter 1: About this document....................5 Chapter 2: Dell PowerEdge XR8000r system configurations and features ........6 System configurations - front view for PowerEdge XR8000r................. 6 System configurations - rear view for PowerEdge XR8000r................... 7 Power supply unit indicator codes...........................7 Locating the Express Service Code and Service Tag....................9...
Page 4
Recycling or End-of-Life service information......................31 Contacting Dell Technologies............................31 Accessing system information by using QRL......................31 Quick Resource Locator for PowerEdge XR8000r system................32 Receiving automated support with Secure Connect Gateway (SCG)..............32 Chapter 6: Documentation resources...................33 Contents...
About this document This document provides an overview about the system, information about installing and replacing components, diagnostic tools, and guidelines to be followed while installing certain components. About this document...
Dell PowerEdge XR8000r system configurations and features The PowerEdge XR8000r system is a 2U rackmount chassis that supports: ● Up to two XR8620t 2U single-width compute sleds ● Up to two redundant AC or DC power supply units Topics: •...
Tech sheet that is shipped with your DC PSU or go to https://www.dell.com/poweredgemanuals > XR Servers > PowerEdge XR8000r > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply.
Page 8
AC PSUs support both 240 V and 120 V input voltages except for Titanium PSUs, which support only 240 V. When two identical PSUs receive different input voltages, they can output different wattages, and trigger a mismatch. Dell PowerEdge XR8000r system configurations and features...
The Mini Enterprise Service Tag (MEST) label is on the rear cover of the system. The MEST includes the Service Tag (ST), Express Service Code (Exp Svc Code), and Manufacture Date (Mfg. Date). The Exp Svc Code is used by Dell to route support calls to the appropriate personnel.
Figure 6. Mechanical overview, System tasks Figure 7. System tasks, Sled installation guide Rail sizing and rack compatibility matrix For specific information about the rail solutions compatible with your system, see the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineering- Docs_Documents/en/rail-rack-matrix.pdf.
Page 11
Dell racks. ● Support tooled installation in 19" EIA-310-E compliant threaded hole 4-post and 2-post racks. ● Support for tooled installation in Dell Titan or Titan-D rack. NOTE: ● Screws are not included with the static rail kit since racks are offered with various thread types. The screws are provided for mounting static rails in racks with threaded mounting flanges.
Technical specifications The technical and environmental specifications of your system are outlined in this section. Topics: • Chassis dimensions • System weight • PSU specifications • Power module assembly • PowerEdge XR sleds ports and connectors • Environmental specifications Chassis dimensions Figure 9.
NOTE: If moving the chassis, it is recommended to remove all the sleds from the chassis. PSU specifications The PowerEdge XR8000r system supports up to two AC or DC power supply units (PSUs). Table 7. PSU specifications Class Heat...
Tech sheet that is shipped with your DC PSU or go to https://www.dell.com/poweredgemanuals > XR Servers > PowerEdge XR8000r > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply...
Figure 10. Power module assembly specifications Table 8. Power module assembly Item Component Description Power distribution board 2/ Chassis This is the power distribution board Manager (PDB2/CM) which provides power to the chassis components. The PSU 2 slot is on the PDB 2.
Ambient temperature for rear air-fllow (RAF) 55°C Non-operating temperature range -40 to 85°C Environmental Considerations The PowerEdge XR8000r system is targeted for edge deployments and it meets all the additional standards for thermal, shock, vibration parameters. Table 12. Environmental considerations Industry Configuration...
Page 17
NOTE: Support operation temperature for the chassis is -20°C ~ 65°C. The sleds limitations are different from the chassis limitations, see dell.com/support. Enter service tag or product name to see the environmental specifications of the sled. Technical specifications...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Tech sheet that is shipped with your DC PSU or go to https://www.dell.com/poweredgemanuals > XR Servers > PowerEdge XR8000r > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply...
Installing a sled blank Prerequisites Follow the safety guidelines listed in Safety instructions. Steps 1. Align the sled blank with the bay of the chassis. 2. Insert and push the sled blank, until it locks into place. Figure 12. Installing a sled blank Removing a sled Prerequisites 1.
Figure 13. Removing a sled from XR8000r Next steps Installing the sled Installing a sled Prerequisites Follow the safety guidelines listed in Safety instructions. Steps 1. Pull the blue lever on the sled to free the sled handle. 2. Holding the sled with both hands, align the sled along the sled-bay into the chassis. 3.
Figure 14. Installing a sled into XR8000r Next steps Follow the procedure listed in After working inside your system. Rear cover Removing the rear cover Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps 1. Using the Torx 8 screwdriver, remove the screws that secure the rear cover on to the chassis. 2.
Figure 15. Removing the rear cover Next steps Replace the rear cover. Installing the rear cover Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps 1. Align and insert the cover on the rear of the chassis. 2. Using the Torx 8 screwdriver, tighten the screws that secure the rear cover on to the chassis. Installing and removing system components...
Figure 16. Installing the rear cover Power module assembly Removing power module assembly Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. Remove the rear cover. 3. Remove the sleds. 4. Remove the power supply units. Steps 1. Using a Phillips 2 screwdriver, loosen the two captive screws. 2.
Figure 17. Removing power module assembly Next steps Replace power module assembly. Installing the power module assembly Prerequisites Follow the safety guidelines listed in the Safety instructions. Steps 1. Align the power tray with four pins in the chassis and insert the power tray along with the power module assembly (PDB) into the chassis.
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same firmware and configuration of the replaced one. For updating to the latest firmware and changing the configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals. Removing a power supply unit blank...
Tech sheet that is shipped with your DC PSU or go to https://www.dell.com/poweredgemanuals > XR Servers > PowerEdge XR8000r > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply.
Tech sheet that is shipped with your DC PSU or go to https://www.dell.com/poweredgemanuals > XR Servers > PowerEdge XR8000r > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply.
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals Installing a power supply unit blank Prerequisites 1.
Page 30
Figure 22. Installing a power supply unit blank Installing and removing system components...
Dell contact information on your purchase invoice, packing slip, bill or Dell product catalog. The availability of services varies depending on the country and product, and some services may not be available in your area. To contact Dell for sales, technical...
Dell. This information is used by Dell Technical Support to troubleshoot the issue. ● Proactive contact — A Dell Technical Support agent contacts you about the support case and helps you resolve the issue.
This section provides information about the documentation resources for your system. To view the document that is listed in the documentation resources table: ● From the Dell support site: 1. Click the documentation link that is provided in the Location column in the table.
Page 34
Methods to download firmware and drivers section in this document. Managing your system For information about systems management www.dell.com/poweredgemanuals software offered by Dell, see the Dell OpenManage Systems Management Overview Guide. For information about setting up, using, www.dell.com/openmanagemanuals >...