Page 1
Operating and Installation Instructions Ventilation System DA 252-4 U DA 259-4 U en - US To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 06 937 210...
IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is designed to vent This appliance is intended for cooking smoke and odors only. residential use only. Use the Be certain your appliance is appliance only for its intended properly installed and grounded by a purpose.
Page 4
Supervise its use by the elderly or certain conditions it may be possible for infirm. installation in these applications. Please contact the nearest Miele dealer or the Never operate gas burners without Technical Service Department with cookware. Turn the burner off when not in use.
Page 5
IMPORTANT SAFETY INSTRUCTIONS , WARNING - TO REDUCE , WARNING TO REDUCE THE RISK OF INJURY THE RISK OF A COOKTOP TO PERSONS IN THE EVENT OF A GREASE FIRE: COOKTOP GREASE FIRE, OBSERVE Never leave surface units THE FOLLOWING: unattended at high settings.
Page 6
IMPORTANT SAFETY INSTRUCTIONS Installation Be careful not to damage hidden electrical wiring or plumbing when , WARNING cutting or drilling into the wall or ceiling. To reduce the risk of fire only use metal ductwork. Do not use an extension cord to connect the appliance to electricity.
Functional description This hood ventilates by recirculating the room air. Air is drawn through the grease filters and active charcoal filters. The cleaned air is then recirculated back into the kitchen through a vent in the hood’s chimney. Before using the hood make sure the active charcoal filters are in place, see "Cleaning and Care".
Page 9
Guide to the appliance a Chimney extension k Indirect light button b Chimney l Overhead light button This button turns the light on and off c Canopy and also dims the light. The lighting can be used independently d Grease filter of the fan.
Operation Turning on the fan Automatically switching back the Intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Press the On/Off button. ^ Turn the fan and the lights off. The fan runs at power level "2".
Page 11
Operation Fan performance The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this If the power level indicators "1" and "4" value. flash the automatic switch back is not Level 1 operates at 40% capacity activated.
Operation Delayed Shut Down Turning off the fan If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the On/Off button to turn the fan off.
Operation Turning the lighting on / off Dimming the lighting The overhead lighting can be turned on The brightness of the lighting can be and off independently of the fan. adjusted. ^ While the lighting is turned on, press the right light button. The lighting will dim until the button is released.
Operation Grease filter timer Checking the grease filter timer A timer monitors the hours of fan To check the percentage of time operation. The indicator for the grease already used: filter will light after 30 hours of operation. The grease filters must then be cleaned.
Page 15
Operation Reprogramming the grease filter timer The grease filter timer is preset to 30 hours. This time can be lengthened or The indicator for the grease filter and shortened to 20, 30, 40 or 50 hours. one of the "–/+" indicators will flash. –...
Cleaning and Care Stainless steel Before cleaning or servicing the hood, disconnect it from the power Stainless steel surfaces can be cleaned supply by either removing the fuse, using a non-abrasive stainless steel unplugging it from the outlet or cleaner. manually "tripping"...
Cleaning and Care Grease filters ^ In a dishwasher: place the filters vertically in the lower basket, making The reusable metal grease filters sure that the spray arm is not remove solid particles from the vented blocked. kitchen air (grease, dust, etc). Use a hot temperature program, e.g.
The active charcoal filters are located in the canopy above the grease filters. Replacement active charcoal filters can be ordered from Technical Service or from your Miele dealer. ^ Follow the installation instructions supplied with the filters. ^ Replace the filters at least every 6 months or when they no longer absorb odors efficiently.
Cleaning and Care Changing the light bulbs Indirect lighting Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become extremely hot, and they can burn your hands.
Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
Page 25
Installation accessories 3 protective shields prevent scratches to the chimney during installation. 4 screws 5 x 60 mm Upper retaining plate for 4 washers 5.3 mm securing the chimney extension. 1 diverter 1 flexible hose 2 hose clips for securing the 6 screws 5 x 40 mm exhaust ducting.
Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the canopy. Its ^ Mark the center of each of the studs mounting bracket must be firmly attached to the stud framing behind...
Page 29
If the standard unit height H is not boiler/fryer. suitable for the kitchen’s ceiling height, longer optional chimney extensions are If local building codes require a available from your Miele dealer or greater safety distance, follow their Miele’s Technical Service Department. requirement. Standard unit H If there is more than one appliance "...
Installation Installation instructions ^ See the enclosed installation instruction sheet. ^ Please read the "Important Safety Instructions" and Installation instructions before installing this hood. Protective film The casing is covered with a protective film to prevent scratching during transport. ^ Peel off the film before installing the casing parts.
Page 32
Alteration rights reserved / 4607 M.-Nr. 06 937 210 / 02 For most the updated manual see the Miele web site.