Page 1
BMI090L Desktop Development 2.0 User Manual BMI090L User Manual Document revision Document release date August 2020 Document number BST-DHW-SD024-00 0 273 017 020 Sales Part Number Notes Data and descriptions in this document are subject to change without notice. Product photos and pictures are for illustration purposes only and may differ from the real product appearance.
DD2.0 UI is a PC based software used to read, capture, and display sensor data. To display the sensor data of BMI090L on DD2.0 UI, mount the sensor on the Bosch Sensortec application board. This is a universal demonstration environment for Bosch Sensortec sensor products.
Bosch Sensortec | BMI090L User Manual 3 | 24 Table of Contents 1. About user manual ..............................2 1.1 Who should read this manual ........................2 1.2 DD2.0 UI Overview ............................2 1.3 Sensor Communication: ..........................2 1.4 Graphical display: ............................2 1.5 Data logging: ..............................2 2.
Page 4
Figure 21 : Selecting USB device corresponding to application board ................ 19 Figure 22 USB driver installation ..........................20 List of tables Table 1 : The technical specifications of the BMI090L sensor ..................5 Table 2 : Troubleshooting ............................20 Modifications reserved | Data subject to change without notice...
The 6-axis IMU combines a 16-bit triaxial gyroscope and a 16-bit triaxial accelerometer in a miniature 3 x 4.5 x 0.95 mm3 (16-pin) LGA package. BMI090L features a closed-loop gyro and a robust accelerometer with a built-in mechanical filter to suppress high-frequency vibrations, thus enabling precise orientation and motion tracking in harsh and demanding industrial environments.
6 | 24 3. Getting Started The below sections highlight the procedure to set up connections between BMI090L, DD2.0 UI, and the PC. 3.1 Setting Up the board-PC connection The procedure to connect sensor to PC via USB is as below: 1.
Bosch Sensortec | BMI090L User Manual 7 | 24 3.2 Startup View To start the DD2.0 UI software: Click Start -> Programs -> Development Desktop 2.0. Double click the DD2.0 UI software icon on the desktop. The Graphical User Interface (GUI) of the software is as seen below: Figure 4 : DD2.0 UI Startup View...
Bosch Sensortec | BMI090L User Manual 8 | 24 The communication status is also indicated at the bottom right of the GUI at all times: Other menu options include: o File o Interface Selection o Panels o Settings o Help These menu options are explained in detail in the following sections.
9. Once firmware upgrade is complete, restart the application board, and DD2.0 UI. 4. Working with DD2.0 UI The functions of BMI090L in DD2.0 UI are discussed in the below sections. 4.1 Sensor Data Monitoring DD2.0 UI offers sensor data monitoring for both accelerometer and gyroscope in BMI090L.
3. 50 Hz 4. 100 Hz 5. 200 Hz 6. 400 Hz 7. 800 Hz 8. 1600 Hz Note: The BMI090L be customized based on the different ranges of ODR Modifications reserved | Data subject to change without notice Document number: BST-DHW-SD024-00...
To reset all values to its default state, click Figure 11 : Reset Button The two sampling rates offered by DD2.0 UI for BMI090L are: Default: A pre- defined sampling rate value supported by the sensor. A pre-defined sampling rate value.
4. 250 ∘ 5. 125 The two sampling rates offered by DD2.0 UI for BMI090L are: 1. Default: A pre- defined sampling rate value supported by the sensor. A pre-defined sampling rate value. 2. Custom: User-defined sampling rate value. Custom sampling rate can only be a value between 100 Hz and 2000 Hz.
Once the interrupt is generated, the following will happen: 1. The interrupt will be plotted in the DD2.0 UI plotter. Using the above procedure, some of the interrupts in BMI090L which can be enabled and verified using DD2.0 UI are as seen below: 1.
Bosch Sensortec | BMI090L User Manual 14 | 24 Figure 14 : Interrupt View Enable Int1, or Int 2, or both. To accomplish this change the below settings in “In Out Control – Interrupt1” (or) “In Out Control – Interrupt2”: 1.
Bosch Sensortec | BMI090L User Manual 15 | 24 Figure 15: FIFO View (Accelerometer) To enable data streaming with FIFO view, follow the steps below: 1. As per requirement, enable the accelerometer. 2. Map the enabled interrupt to Int1, Int2, or both.
Bosch Sensortec | BMI090L User Manual 16 | 24 Figure 16 : FIFO View (Gyroscope) 4.3.4 Binary View To view the data in binary format, go to Menu -> Panels -> Memory Map -> Binary View, or click Ctrl+K. The following...
Bosch Sensortec | BMI090L User Manual 17 | 24 Figure 18 Binary : Gyroscope view 4.3.5 Register Access To go to Register Access, go to Menu -> Panels -> Register Access, or click Ctrl+R. The register access provides the user an option to choose accelerometer (or) gyroscope The following window appears: Register Access used to read or write values into a register.
Bosch Sensortec | BMI090L User Manual 18 | 24 Enter the hexadecimal data you wish to read/ write in Data [h]. Select the data bits into which data has to be write or read As per requirement, click Read/Write.
Bosch Sensortec | BMI090L User Manual 19 | 24 5. General Troubleshooting Follow below guidelines while working with DD2.0 UI: Ensure that the shuttle board (with a valid sensor) is seated properly in the application board. Ensure that the PC-board connection is properly established.
Bosch Sensortec | BMI090L User Manual 20 | 24 Figure 22 USB driver installation The following table lists some of the possible faults that you might encounter and the troubleshooting method. Table 2 : Troubleshooting Condition Possible cause Solution If Communication Status remains Application Board is turned off.
Page 21
Bosch Sensortec | BMI090L User Manual 21 | 24 Error message Please select File Destination path not selected. In the file menu, select the Data from File Menu Data Export Export option and select the option to proceed is displayed.
(including but not limited to satellite technology). The resale and/or use of Bosch Sensortec products are at the purchaser ’s own risk and his own responsibility. The examination of fitness for the intended use is the sole responsibility of the purchaser.
Bosch Sensortec | BMI090L User Manual 23 | 24 7. Document history and modification Rev. No Chapter Description of Date modification/changes BMI090L User Manual Initial release July 2020 BMI090L User Manual Adopt New Format August 2020 Modifications reserved | Data subject to change without notice...
Page 24
Bosch Sensortec | BMI090L User Manual 24 | 24 Bosch Sensortec GmbH Gerhard-Kindler-Straße 9 72770 Reutlingen / Germany contact@bosch-sensortec.com www.bosch-sensortec.com Modifications reserved Preliminary - specifications subject to change without notice Document number: BST-DHW-SD024-00 Bosch Sensortec GmbH Gerhard-Kindler-Straße 9 Modifications reserved | Data subject to change without notice...