Troubleshooting
14 Troubleshooting
14.1 Self-diagnosis/error indications
The unit offers comprehensive self-diagnostic options.
• It monitors itself during operation.
• Warnings and error states are signaled on the display (also when
the display is deactivated) and are additionally made available via
IO-Link.
None
SC1
Flash-
flash-
es
es
Loc
C.Loc
RE 30277-02-B/07.2016, HEDE 10-3X, Bosch Rexroth AG
Type of fault
F
Supply voltage too low
F
Excessive current at
switching output OUT1
*
)
W
Parameter setting
locked via pushbuttons.
W
Parameter setting
locked via pushbuttons,
Para-metrierung über
IO-Link-Kommunikation
ist active (→ see page
29).
Corrective measures
Check / correct supply
voltage.
Check switching output
OUT1 for short-circuit
or excessive current;
remove the fault.
Unlock pushbutton lock
(→ see page 29)
Wait until parameter
setting via IO-Link is
finished.
43/48