10.1 Open the Service Valves 17.2 Maintenance – Pre-Season Inspection 11 Electrical - Low Voltage 11.1 Low Voltage Maximum Wire Length 11.2 Low Voltage Hook-Up Diagrams 11.3 Thermostat Wiring Diagrams Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
This information is intended for use by individuals possessing adequate backgrounds of electrical and mechanical experience. Any attempt to repair a central air conditioning product may result in personal injury and/or property damage. Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 5
P65Warnings.ca.gov. CAUTION: INDOOR UNIT REQUIRED The indoor units must be matched with TXV. The model of TXV can be changed according to the system capacity. Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Min. 12" to Shrubbery Min. 24" to Approximately every three months, wash the outdoor coil and any Wall exposed cabinet surfaces. Access Panel Figure 4 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
1/4” Χ 1-1/2” Hex washer head concrete screws (3/16” pilot hole needed. Pilot hole should be 1/4” deeper than the fastener embedment) Figure 8 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
The Suction Line must always be insulated. DO NOT allow the Liquid Line and Suction Line to come in direct (metal to metal) contact. Suction Line Liquid Line Insulation Figure 10 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Secure Suction Line using isolators every 8 ft. Secure Liquid Line directly to Suction Line using tape, wire, or other appropriate method every 8 ft. Isolation On Walls Figure 12 1 0 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Remove caps or plugs. Use a deburring tool to deburr the pipe ends. Clean both internal and external surfaces of the tubing using an emery cloth. Figure 14 | 11 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 12
Continue the dry nitrogen purge. Do not remove the wet rag until all brazing is completed. Remove the wet rag before stopping the dry nitrogen purge. 1 2 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Once evacuation is complete, turn off the vacuum pump and micron gauge, and close the valves on the manifold gauge set. 1 MIN. Figure 22 Figure 20 | 13 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Replace the Valve Stem Cap to prevent leaks. Tighten finger tight plus an additional 1/6 turn. Repeat STEPS 1 - 3 for Liquid Service Valve. 1 4 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Figure 25 the first stage electric auxiliary heat. Figures 25-30 refer to thermostat wiring diagrams for the BOVA15 and BVA15 manufacturer matched indoor and outdoor systems. | 15 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 16
Installation Instructions Figure 26 Thermostat Wiring Diagram for BOVA15/BVA15 Matched System 1 6 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
12.2 High Voltage Disconnect Switch Install a separate disconnect switch at the outdoor unit. Field supplied fl exible electrical conduit must be used for high voltage wiring. Figure 27 | 17 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Upon initial unit installation, wait one (1) hour before starting the unit if compressor crankcase heater is used and the outdoor ambient temperature is below 70 ºF. 60 MIN. Figure 31 1 8 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
"Force Mode". Outdoor temperature must be between 55°F and 120°F Ensure Sections 7,8,9,10,11,12 and 13 have been completed. with indoor temperature kept between 70°F and 80°F. | 19 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 20
Measured Liquid Line Pressure = _______ PSIG Calculate subcooling value = ________ºF Table 8 R-410A Refrigerant chart - Final Subcooling Insulation Figure 36 2 0 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 21
Wait 5 minutes for the system condition to stabilize between adjustments. When the subcooling matches the design value (Table 9), the system is properly charged. | 21 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
20 minutes. Defrost will terminate once outdoor coil temperature (T3) reaches 64°F for a period of 1 minute or defrost time has exceeded 8 minutes. 2 2 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Hz), the unit will continue to run but in a limited condition. The only exception is when the system is in defrost mode, which only displays "dF" (without any numerical digits following). 2 4 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
AC voltage of power input (V) DC voltage (V) of compressor input Continuous running time of the compressor (min) Last fault code Software version Remark“--” Table 14 | 25 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
SW4 Dip SWITCH:Control logic settings SW6 Dip SWITCH: Select capacity DC motor port Compressor: W port Compressor: V port Compressor: U port Power input Power input Reserve Figure 40 2 6 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 27
SW4 Dip SWITCH:Control logic settings SW6 Dip SWITCH: Select capacity DC motor port Compressor: W port Compressor: V port Compressor: U port Power input Power input Reserve Figure 41 | 27 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Replace T4 sensor T4 sensor in the range of Table there another Remove all other heat source near heat sources T3/T4? Replace control board Figure 42 2 8 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 29
(U2,V2,W2) (CN32) >36Ω, and/or Replace motor the resistance between compressor winding and ground >10MΩ? Did the Replace control board fail? control board Restart system Figure 45 | 29 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 30
Is the main control chip properly installed? the connection Does main control chip Power off and correct have poor contact? the contact Replace control board Figure 48 3 0 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 31
Tighten the screws and/or or is there enough apply silicone grease Restart system silicone grease? Figure 49 Did the control Replace control board board fail? Restart system Figure 50 | 31 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 32
Figure 52 Is the system Adjust refrigerant overcharged? Is the high pressure switch Replace high connected correctly and pressure switch resistance ≥1Ω? Restart system Figure 51 3 2 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 33
>11.5A for 2/3T and >15.5A for Is the compressor current >11.5A 4/5T? Replace compressor for 2/3T and >15.5A for 4/5T? Restart system Restart System Figure 53 Figure 54 | 33 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 34
T3 and T5 sensors Ensure they are correctly placed after properly placed service? Is the Adjust or replace EEV/TXV working EEV/TXV normally? Restart System Figure 55 3 4 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 35
Table Is the Replace compressor current >11.5A compressor for 2/3T and >15.5A for 4/5T? Restart System Figure 57 Replace control board Figure 58 | 35 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 36
T4 sensor seated diagram for correctly? correct connection Is the resistance of T4 Replace T4 sensor in the range of Table 15? Restart system Figure 59 3 6 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. Make sure nothing is blocking all air inlets and outlets and clean the coils as necessary Figure 62 | 41 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 42
Installation Instructions NOTES: 4 2 | Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 43
Installation Instructions NOTES: | 43 Bosch IDS BOVA15 Split System Heat Pump - BTC 761701317 A (02.2022)
Page 44
United States and Canada Bosch Thermotechnology Corp. 65 Grove St. Watertown, MA 02472 Tel: 866-642-3198 Fax: 954-776-5529 www.bosch-thermotechnology.us BTC 761701317 A / 02.2022 Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances.