Page 1
SE2417HG 1. Disassembly Procedures: Step Figure Remark Turn off power, S1.Before Unplug external cables disassemble from product To remove the stand: Press the button on the red circle then pull out the stand follow the arrow, stand will be remove.
SE2417HG Use a Philips-head screwdriver to remove 2 screws for unlocking mechanisms. (No.1~2 screw size=M3x4; Torque=4±1kgf.cm) S3.Remove the REAR COVER Use Penknife to separate the bezel and rear cove follow the arrows in sequence, then you can take out rear cover.
SE2417HG S6.Remove the FFC cable S7.Remove the PAPER TAPE and panel FFC cable S8.Remove the Remove and turn over it. MAIN FRAME...
Page 4
SE2417HG Use a Philips-head screwdriver to remove 5 screws for unlocking main board and power board (No.1~4 screw size=D3x6; Torque=6±1kgf.cm S9.Remove the No.5 screw size=M4x6; MAIN &POWER Torque= 6±1kgf.cm) BOARD Remove the cables Use a Philips-head screwdriver to remove 4 screws for unlocking Key S10.Remove the...
Page 5
SE2417HG S11.The PANEL Use a Philips-head screwdriver to remove S12.Remove the 1screws for unlocking main frame screw (No.1 screw size= Q3x6 Torque=4±1kgf.cm) S13.The MAIN FRAME S14.The BEZEL...
Page 6
SE2417HG Remove electrolyte capacitors (red mark) from printed circuit boards S15.Remove capacitor Take out bulk cap. pin solder with soldering iron and absorber Lift the bulk cap. up and away from the PCB...
SE2417HG 2. Product material information The following substances, preparations, or components should be disposed of or recovered separately from other WEEE in compliance with Article 4 of EU Council Directive 75/442/EEC. Capacitors / condensers (containing No used PCB/PCT) Mercury containing components...