en | Mechanical installation of Central Equipment
Front panel
Figure 6.7: OMN-DANTEGTW front panel description
Power LED state Description
Steady yellow (1) The Dante gateway is still
Blinking yellow
(1)
Steady green (2)
Alternating
yellow/green
2021.01 | V2.2 |
booting/connecting to the
network
The Dante gateway is
experiencing a problem
The device is fully operational
and discoverable at both the
TM
Dante
and the OMNEO sides
The AES70 identify function is
active
Hardware Installation Manual
How to solve
–
Wait until fully booted, this takes
about 30 seconds.
–
Make sure at least one of the
network connectors at the Dante
side has a link indication.
–
Connect the OMNEO side to an
Ethernet network. The Ethernet
connector must show the link
indication.
–
If there are multiple Dante
gateway's in the same OMNEO
network, make sure the Dante
side of these gateways is also in the
TM
same Dante
network.
–
Make sure there is no network
connection between the Dante
and the OMNEO side. This is never
allowed.
–
If there is only a single Dante
gateway, use the Dante controller
to set the Dante gateway as
preferred clock master.
–
If these tips do not solve the
problem, the device is broken and
needs to be exchanged.
N/A
–
Disable the Identify function (e.g.
via Docent). Rebooting the device
will also cancel this function.