en | Mechanical installation of Central Equipment
Front panel
Figure 6.7: OMN-DANTEGTW front panel description
Power LED state Description
Steady yellow (1) The Dante gateway is still
Blinking yellow
(1)
Steady green (2)
Alternating
yellow/green
2021.01 | V2.2 |
booting/connecting to the
network
The Dante gateway is
experiencing a problem
The device is fully operational
and discoverable at both the
TM
Dante
and the OMNEO sides
The AES70 identify function is
active
Hardware Installation Manual
How to solve
Wait until fully booted, this takes
about 30 seconds.
Make sure at least one of the
network connectors at the Dante
side has a link indication.
Connect the OMNEO side to an
Ethernet network. The Ethernet
connector must show the link
indication.
If there are multiple Dante
gateway's in the same OMNEO
network, make sure the Dante
side of these gateways is also in the
TM
same Dante
network.
Make sure there is no network
connection between the Dante
and the OMNEO side. This is never
allowed.
If there is only a single Dante
gateway, use the Dante controller
to set the Dante gateway as
preferred clock master.
If these tips do not solve the
problem, the device is broken and
needs to be exchanged.
N/A
Disable the Identify function (e.g.
via Docent). Rebooting the device
will also cancel this function.