E9: Protection and error parameters
Code
E9.00 Automatic error reset attempts
E9.01 Automatic error reset interval
E9.02 Automatic error reset attempts restart time 0...65,535
E9.05 Last error type
E9.06 Second last error type
E9.07 Third last error type
E9.10 Output frequency at last error
E9.11 Setting frequency at last error
E9.12 Output current at last error
E9.13 Output voltage at last error
E9.14 DC-bus voltage at last error
E9.15 Power module temperature at last error
E9.97 Last error detail
E9.98 Second last error detail
E9.99 Third last error detail
Value range of E9.05...E9.07:
0: No error
1: OC-1, overcurrent at constant speed
2: OC-2, overcurrent during acceleration
3: OC-3, overcurrent during deceleration
4: OE-1, overvoltage at constant speed
5: OE-2, overvoltage during acceleration
6: OE-3, overvoltage during deceleration
7: OE-4, overvoltage during stop
8: UE-1, undervoltage during run
9: SC, surge current or short circuit
10: IPH.L, input phase loss
11: OPH.L, output phase loss
12: ESS-, soft start error
20: OL -1, converter overload
21: OH, converter over temperature
23: FF, fan failure
DOK-RCON04-VFC3210****-IT01-EN-P