Useful features and the detail of system BIOS settings, RAID Features Configuration Utility, and EXPRESSBUILDER Chapter 3: Appendix Error messages and Windows Event Logs Other documents Provides the detail of NEC ESMPRO, Universal RAID Utility, and the other features. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Unless otherwise stated, Hard disk drives (HDD) described in this document refer to the following. • Hard disk drives (HDD) • Solid state drive (SSD) Removable media Unless otherwise stated, removable media described in this document refer to the following. • USB memory Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Oracle Linux 6.4/UEK R2 or later (x86_64) POST POST described in this document refer to the following. • Power On Self-Test BMC described in this document refer to the following. • Baseboard Management Controller Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Web Console WEB Console described in this document refer to the following. • Web browser to use remote management feature via HTTP/HTTPS protocol using EXPRESSSCOPE Engine SP3 (BMC), and contents used for remote management control. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Trademarks Trademarks EXPRESSSCOPE is a registered trademark of NEC Corporation. Microsoft, Windows, Windows Server, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Intel and Xeon are registered trademarks of Intel Corporation of the United States. AT is a registered trademark of International Business Machines Corporation of the United States and other countries.
Outside the European Union If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority and ask for the correct method of disposal. This product is RoHS compliant Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 11
○ ○ 等) ○:表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006标准规定的限量要求以 下。 ×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006标准规定的限量要 求。 Vietnam RoHS information relevant for Vietnam market Complying with "CIRCULAR, No.30/2011/TT-BCT (Hanoi, August 10 2011), Temporary regulations on content limit for certain hazardous substances in electrical products" Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 12
миллионных частей; полибромбифенолы (PBB) – не превышает 0,1 % веса вещества или в концентрации до 1000 миллионных частей; полибромдифеноловые эфиры (PBDE) – не превышает 0,1 % веса вещества или в концентрации до 1000 миллионных частей. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Warnings and Additions to This Document Warnings and Additions to This Document 1. No part of this document may be reproduced in any form without the prior written permission of NEC Corporation. 2. The contents of this document may be revised without prior notice.
NEC Express5800 Series Express5800/A1040b, A2040b, A2020b, A2010b Maintenance This chapter explains maintenance of server, and what actions are to be taken in case of trouble when operating this server. 1. Transfer, Movement, and Disposal Describes how to transfer this server to a third party. Also describes how to dispose, relocate and store this server.
Important NEC assumes no liability for data leakage should the product be transferred to a third party without erasing the data. Data seems to be erased when you empty "Recycle Bin" of Windows or execute the "format" command of the operating system.
Some components including cooling fans, batteries, and the optical disk drive work for a limited period of time and require replacement. For stable operation of the server, NEC recommends you regularly replace these components. Contact your sales representative for information on replacement or the lifetime of components.
Safety precautions in Precautions for Use in "User’s Guide". • Make sure to complete installation. • Do not get your fingers caught. • Be careful of handling internal components that may be hot. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 18
Mesures de sécurité dans Précautions d’utilisation dans « Guide de l’utilisateur ». • Assurez-vous de terminer l’installation. • Faite attention à ne pas coincer vos doigts. • Faites attention en manipulant les composants internes qui peuvent être chauds. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 19
Precauzioni per l'uso nella “Guida per l'utente”. • Accertarsi di completare l'installazione. • Prestare attenzione a non schiacciarsi le dita. • Prestare attenzione durante la manipolazione di componenti interni che possono essere caldi. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 20
Eigentum kommen. Einzelheiten finden Sie auf Sicherheitsmaßnahmen in Vorsichtsmaßnahmen beim Gebrauch im „Bedienungsanleitung“. • Achten Sie darauf, die Installation abzuschließen. • Klemmen Sie Ihre Finger nicht ein. • Seien Sie vorsichtig bei der Behandlung von internen Komponenten, die heiß sein könnten. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 21
Precauciones de seguridad en la sección Precauciones de uso de la “Guía del usuario”. • Asegurarse de completar la instalación. • Evitar que sus dedos queden atrapados. • Tenga cuidado al manipular los componentes internos que pueden estar calientes. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 22
When storing the server, monitor the environmental conditions of the storage area (temperature: −10°C to 55°C, humidity: 20% to 80%). (No dew condensation is permitted) Make backup copies of important data stored in the hard disk drive. Tips Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 23
Check and adjust the system clock before operating after relocating or storing Note the server. • If the system clock time is significantly delayed or advanced over time in spite of adjustment, contact your sales representative. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Checking and Applying Updates Express5800 Series posts update information for BIOS, FW (firmware), driver, and others of the server and peripheral devices on our website. We recommend that the latest update always be applied for stable system.
Le non-respect de ces instructions risque de vous blesser mortellement ou sérieusement. Pour plus de détails, consultez Mesures de sécurité dans Précautions d’utilisation dans « Guide de l’utilisateur ». • Ne démontez pas, ne réparez pas et ne transformez pas le serveur. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 26
Precauciones de uso de la “Guía del usuario”. • No desmonte, repare ni modifique el servidor. • Desconecte el enchufe antes de limpiar el servidor. 为了安全使用本设备,请务必遵守以下的注意事项。否则有导致人员死亡或者重伤的危险。详情请参照【用 户指南】的【使用注意事项】。 请勿自行对本设备进行拆卸、修理或改造 请勿在电源插头插入的状态下操作 Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
SYSTEM POWER LED is off. An optical mouse does not work properly if the optical sensor is not clean. Wipe the sensor with a dry cloth to remove any dirt or dust. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Use only cleaner dedicated to CD/DVD media. Cleaning a CD/DVD media with record spray/cleaner, benzene, or thinner causes damage to the CD/DVD media contents. At worst, inserting the CD/DVD media into the server may cause failure. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
User Support Before getting after-sales service, check the contents of the warranty and service. Maintenance Services Service representatives from NEC subsidiary companies or companies authorized by NEC provide maintenance services. For the services, contact your sales representative. Before Asking for Repair If you think that a failure occurred, follow the steps below: 1.
Click Settings on the charm bar. To go to step 5, you can directly choose Event Viewer on the menu that appears when you right click on the lower left corner of the screen. [Settings] [Event Viewer] Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 31
Chapter 1 Maintenance 4. Collecting Failure Information Click Control Panel from Settings. Click System and Security of Control Panel. Click Administrative Tools and then click View event logs of System and Security. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Click Save All Event As... from Action menu. Type the file name of the archived log in File name. Select the type of the log file you want to save in Save as type, and then click Save. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
2. Type msinfo32.exe in the text box, and then press the <Enter> key. [Search] [Run] 3. System Information starts. 4. Click Export from File menu. 5. Type a file name to save in File Name, and then Click Save. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
When OS is started, following two logs are registered. These do not affect operation of the Tips system. ・pnp 00:0b: disabling [mem 0xadf00000-0xadffffff] because it overlaps 0000:00:1c.7 BAR 14 [mem 0xac000000-0xadffffff] ・pnp 00:0b: disabling [mem 0xadef0000-0xadef0fff] because it overlaps 0000:00:1c.7 BAR 14 [mem 0xac000000-0xadffffff] <How to collect event logs> Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
OS or contained in OS media. Consult with your sales representative before dumping the memory. Dumping the memory while the server is in operating normally may affect the system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
POWER switch is pressed. The POWER LED lights amber during initialization. Press the POWER switch after the POWER LED turns off. Nothing is displayed on screen → It may take time to display NEC logo. Wait for a while. POST does not complete ...
→ If not, make sure that Internal Flash Memory is connected correctly. See Chapter 2 (5. Details of EXPRESSBUILDER). Did you purchase Internal Flash Memory as BTO? → If not, copy EXPRESSBUILDER to Internal Flash Memory first. See Chapter 2 (5. Details of EXPRESSBUILDER). Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Have you checked precautions for installation? → For installing OS, refer to "Installation Guide (Linux)". A product key was not requested → If you install using the backup DVD-ROM, entering the product key is not required. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 39
→ "Create a parameter file for Windows OS" must be run using Microsoft ® HTML Application host. If it ® does not start, associate the file type with Microsoft HTML Application host via the following process. (1) Select Run in Windows Start menu. (2) Enter %windir%\system32\mshta.exe/register. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
→ Change the boot device configuration from HDD Drive BBS Priorities of the BIOS Setup Boot menu. Is BIOS configuration correct? → On [Boot Priorities] menu of BIOS SETUP, confirm that [Windows Boot Manager] has the upper priority than other boot devices. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
→ If you want to turn off the power at the blue screen, execute forced shutdown (continue to press the power switch for 4 seconds). If you press the switch briefly instead of holding it, the server will not power off. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
→ If the battery charging status is low, the battery may not be recognized. If the battery is not recognized although 24 hours has passed, restart the system once. If the battery is still not recognized although the above action has been taken, the extra battery may be faulty. Contact your service representative. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 43
DISK LED flashes frequently even while the Hard Disk Drive is not accessed. → When Patrol Read is running, the DISK LED flashes even if the Hard Disk Drive is not being accessed. If SATA Hard Disk Drive is used, the DISK LED may stay on. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 44
To display correct controller name, run the following command stored in the EXPRESSBUILDER DVD and reboot the system. Windows Server 2012: Drive letter of optical disk:\002\win\winnt\ws2012\elxfc\friendlyname.exe Windows Server 2008 R2: Drive letter of optical disk:\002\win\winnt\ws2008x64\elxstor\friendlyname.exe Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Unable to access the Hard Disk Drive Is the Hard Disk Drive supported by the server? → Operation of any device that is not authorized by NEC is not guaranteed. Is the Hard Disk Drive properly installed? → Check the Hard Disk Drive installation status and the cable connections.
(The rest is omitted.) → Even if this message is registered in Windows Event Log, since the retry operation was successful in hardware and firmware, there is no problem. Use the system as it is. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
→ For details of NEC ESMPRO Manager, see "NEC ESMPRO Manager Installation Guide" in EXPRESSBUILDER or its help. NEC ESMPRO Agent (Windows) → For details of NEC ESMPRO Agent, refer to "NEC ESMPRO Agent Installation Guide (Windows)" in EXPRESSBUILDER or its help. NEC ESMPRO Agent (Linux) →...
[?] Unable to turn off the power Is the suppression feature of the SYSTEM POWER switch enabled? → Restart the system once and start the BIOS setup utility. The menu to be confirmed: Server → Power Switch Inhibit Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
(if the system is power on, restart the system after performing Clear All Faults). → Configuring the environment which can be supplied from two electric power companies or using UPS is recommended as a means to prevent AC power from not being supplied. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
We recommend that this option is performed by the system administrator. For details, refer to Windows Help. Recovery of Linux System If any file necessary for running Linux is damaged, refer to the manual related to setup procedure provided with your OS or contained in OS media. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
To reset the BMC, press BMC RESET Switch at least five seconds. BMC RESET Switch resets only BMC and that does not reboot the server. Tips Example: A2040b/ A2020b/ A2010b BMC#1 RESET switch BMC#2 RESET switch Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
If the remote power-on function is used, cycle the power once to load the OS after the power has been forcibly turned off, and then turn off the power again by shutting down the SYSTEM POWER Switch (Keep pressing for at least 4 seconds) Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
When executing the system diagnostics, be sure to disconnect LAN cable. Executing the system diagnostics with the LAN cable connected may affect the network. On checking hard disk drives, no data is written to the disk. Tips Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
"ELILO boot:". When the system starts without entering the boot option, system diagnostics is performed on SOL screen. ELILO boot: .. [option] <ENTER> Console used for system diagnostics Boot option Not specified Serial tedoli tedoli_vga Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
044 ETH Run / 081 ETH Run / 082 ETH Run / 091 ETH Run 092 ETH Run / 093 ETH Run / 094 ETH Run / USB DOM Run DVD FAIL / SERIAL1 Run / VGA1 Run / Execution Status (SOL/Serial) Execution Status (VGA) Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Select Reboot or Shutdown. *********************************************************** Please select next action. *********************************************************** 1: Attempt to retry the test 2: Reboot 3: Shutdown Enter selection [Shutdown]: 2 Exit menu (SOL/Serial) Exit menu (VGA) This completes System Diagnostics. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
BMC Configuration – Used to provide settings for alert feature by Baseboard Management Controller (BMC) and for using remote management feature from management PC. BMC Configuration Initialization – Used to initialize BMC configuration data. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Describes the EXPRESSBUILDER attached to the server. 5. EXPRESSSCOPE Engine SP3 Describes EXPRESSSCOPE Engine SP3. 6. NEC ESMPRO Describes NEC ESMPRO Agent and NEC ESMPRO Manager, applications to manage and monitor the server. 7. NEC Product Info Collection Utility Describes the NEC Product Info Collection utility 8.
Main menu • Advanced menu • Security menu • Server menu • Boot menu • Save & Exit menu These menu has submenus for relevant items. Selecting submenus allows you to configure further detailed parameters. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
(an NTP server) is recommended. If the system time becomes considerably slow or fast over time even though you regularly adjust it, contact the agent where you purchased the server or the maintenance service company for maintenance. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
If you move the cursor to Advanced, the Advanced menu appears. For the menus that show a “ ” to their left, select a menu and press the <Enter> key to display its submenu. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 65
Enabled in usual operation. This option needs to be [Enabled] disabled for booting a specific OS. Refer to Chapter 4 (3. Settings for each OS) in User's Guide. Processor Error Mode Specify the error mode of processor. [Poison] ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 66
Shows whether the Intel 64 architecture is supported on Not Supported Processors 1 to 4 or not. Hyper-Threading Supported Shows whether the Hyper-Threading Technology is Not Supported supported or not on Processors 1 to 4. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 67
Enable or disable the Turbo Boost Technology feature. [Enabled] This option is displayed only when the installed processor supports this feature. This option is displayed only when EIST is set to Enabled. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 68
If Intra is selected, memory modules in socket are interleaved. Patrol Scrub Disabled Enable or disable memory RAS feature (Patrol Scrubbing). [Enabled] Demand Scrub Disabled Enable or disable memory RAS feature (Demand Scrubbing). [Enabled] Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 69
Number (Spared) Not Present: Indicates no DIMM is installed. Number (Mirrored / Lock Step / Spared): Indicates memory capacity and specified mode (Mirrored / Lock Step / Spared) in memory RAS mode. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 70
Disabled assigned to PCI card at BMC failover. This item is [Enabled] displayed only for other than Express5800/A1040b. This parameter value needs to be changed depending on OS to boot. Refer to Chapter 4 (3. Settings for Each OS) for details.
Page 71
]: Factory settings Note If RAID Controller, LAN card (network boot), or Fibre Channel controller does not connect with a hard disk drive that contains an OS, set the option ROM for that slot to Disabled. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 72
For details about the options, see the table below. Option Parameter Descriptions PCI1-16 LinkSpeed Limit 2.5 GT/s Specify the upper limit of link speed of each PCI slot. 5.0 GT/s [8.0 GT/s] ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 73
SR IOV Support [Disabled] Enable or disable Single Root I/O Virtualization feature. Enabled Wake On LAN/PME Disabled Enable or disable the feature that remotely powers on [Enabled] through a network. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 74
For details about the options, see the table below. Option Parameter Descriptions SATA Information – SATA Mode Disabled Set SATA Mode. [IDE Mode] AHCI Mode ]: Factory settings Note NEC has not verified AHCI driver support. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 75
1. System BIOS (a) SATA Information submenu For details about the options, see the table below (display only). Option Parameter Descriptions SATA Port – Shows a device connected to SATA port. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 76
USB Mass Storage Device. 30 sec 40 sec Controller Timeout 1 sec Specify the timeout period when Control, Bulk, and 5 sec Interrupt Transfer commands are issued to USB 10 sec Controller. [20 sec] ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 77
Serial B Base I/O 3F8h Specify the base I/O address for serial port B [2F8h] 3E8h 2E8h Serial B Interrupt IRQ 4 Specify the interrupt for serial port B [IRQ 3] Console Redirection Settings – – Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 78
Specifying [Serial Port A] or [Serial [Serial Port B] Port B] (only either can be specified) allows direct connection via terminal unit such as NEC ESMPRO Manager, and options for connection shown below are displayed. Terminal Type [VT100+] Select the terminal type.
Page 79
Option Parameter Descriptions iSCSI Initiator Name Alphanumeric Specify iSCSI Initiator Name with IQN format. characters (Example: iqn.2001-03.jp.nec:initiator) Add an Attempt – – Delete Attempts – – Change Attempt Order – – ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 80
Select a port and press the <Enter> key to display submenu to set parameter. ]: Factory settings If you select a port used for iSCSI boot and press the <Enter> key, a submenu to set parameter is displayed. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 81
One way: Only iSCSI target authenticates iSCSI Initiator. Mutual: iSCSI target and iSCSI Initiator authenticate each other. CHAP Name Alphanumeric Specify CHAP Name that the target authenticates. characters (up to 16 characters) Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 82
Commit Changes and Exit – Delete the specified Attempt and return to iSCSI Configuration submenu. Discard Changes and Exit – Does not delete the specified Attempt and return to iSCSI Configuration submenu. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 83
Commit Changes and Exit – Save the changed Attempt order and return to iSCSI Configuration submenu. Discard Changes and Exit – Does not save the changed Attempt order and return to iSCSI Configuration submenu. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Security Configuration – – Password On Boot [Disabled] Enable or disable the feature that requires a password Enabled entry on boot. This option can be selected when Administrator Password is set. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 85
Administrator Password has been set. This option is displayed only when TPM device is installed. ]: Factory settings Trusted Computing submenu From the Security menu, select Trusted Computing and then press the <Enter> key to display the menu screen shown below. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 86
Directed I/O feature (Virtualization of I/O feature). This option is displayed only when the installed processor supports this feature. This option is inaccessible when Intel TXT Support is set to Enabled. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Boot Monitoring [Disabled] Enable or disable the boot monitoring feature. Enabled To use this feature, NEC ESMPRO Agent must be installed on OS. If starting up an OS on which it is not installed, disable this feature. Boot Monitoring Time Number Specify boot monitoring timeout.
Page 88
If [Yes] is selected, clears error information related to system resource such as CPU/memory and reconfigure all the necessary resources at next boot of SETUP. This parameter is automatically reset to [No] after system resources are reconfigured. ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 89
– Shows the revision of Sensor Data Record. ME Version – Shows the firmware version of Management Engine. Descriptor Revision – Shows the revision of descriptor. Chipset Revision – Shows the revision of chipset. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 90
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to show its submenus. For details about the options, see the table below. Option Parameter Descriptions PSU Redundancy Specify the redundancy of power supply units. [2N] ]: Factory settings Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
UEFI USB Floppy Drive BBS – Priorities UEFI Hard Disk Drive BBS Priorities – UEFI USB Key Drive BBS Priorities – UEFI USB Hard Disk Drive BBS – Priorities UEFI Network Drive BBS Priorities – Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 92
OS boot entry is cleared. To recover OS boot entry, restore the configuration file backed up by using Backup/Restore feature of Remote Management or set it again with the tool on OS. Refer to Chapter 3 (7.7.3 Backup/Restore) in User's Guide for more information. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
If you change BIOS SETUP parameters, be sure to backup the configuration information by using Backup/Restore feature of Remote Management. Refer to Chapter 3 (7.7.3 Backup/Restore) in User's Guide for more information. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Starts from 1 Drive group (Disk Array) Starts from 0 Starts from 1 To be assigned based on an enclosure Drive (Physical Device) Starts from 0 that contains the physical device and its slot number. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 96
• Tips WebBIOS can specify the background initialization priority, but Universal RAID Utility cannot. • Although Universal RAID Utility can specify the priority of initialization (Slow Initialize), this server does not support this function. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Memory is connected correctly. See a) in Chapter 2 (4.3 Utilities Provided by EXPRESSBUILDER - (4) Internal Flash Memory. When EXPRESSBUILDER is started from Internal Flash Memory, Boot Selection Menu shown in Chapter 2 (4.2 Menus of EXPRESSBUILDER) - (1) Boot Selection Menu appears. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Starts a utility stored in EXPRESSBUILDER. For details about the provided utilities, see Chapter 2 (4.3 Utilities Provided by EXPRESSBUILDER). c) Versions Displays software and driver versions in EXPRESSBUILDER. d) Exit Select this menu to quit EXPRESSBUILDER. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 99
You can read Instruction Manuals or install bundled software using Autorun Menu. Adobe Reader is required to view or print manuals. Integrated Installation You can easily install Starter Pack or applications using this feature. If you want to uninstall the applications or install individually, choose Applications. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
You can save the data to Internal Flash Memory when Internal Flash Memory is installed. File Execution Directly runs a external utility on removable media. Use this feature only for utilities provided by NEC. Note Do not run the file provided by the third party.
Page 101
Update Copies data of the EXPRESSBUILDER disc or other media to Internal Flash Memory. The data is overwritten and all previous data is cleared. The parameter file and RAID configuration data are retained. Tips Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Accessing a CD-ROM, DVD ROM, floppy disk, ISO image, or USB flash drive in the server To actualize these functions, virtual USB mass storage (Remote FD, Remote CD/DVD, Remote USB Memory, or Virtual Flash) is always connected as USB mass storage. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
EXPRESSBUILDER or its help. NEC ESMPRO Manager NEC ESMPRO Manager can remotely control and monitor the hardware and the RAID system of the server. To use these features, install the bundled software for the server such as NEC ESMPRO Agent.
Chapter 2 Convenient Features 6. NEC ESMPRO NEC ExpressUpdate Agent NEC ExpressUpdate Agent enables you to manage and update the versions of the firmware and software installed in the managed server. You can install the downloaded packages easily by using NEC ExpressUpdate.
7. NEC Product Info Collection Utility NEC Product Info Collection Utility NEC Product Info Collection Utility can collect various information related to the server all at once. This utility allows you to collect server information (Product Info) for maintenance. Usage (Windows) Execute ¥stdclct¥collect.exe contained in the installation folder of this utility.
You must use four or more Physical Devices to create a RAID 6 Logical Drive by using Universal RAID Utility. If you want to create a RAID 6 Logical Drive with three Physical Devices, you need to use WebBIOS. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
NEC Express5800 Series Express5800/A1040b, A2040b, A2020b, A2010b Appendix 1. POST Error Message Shows a list of error messages for errors detected by a self diagnostic test called POST. 2. List of Windows Event Logs Shows a list of Windows event logs 3.
Write down the displayed messages and beep patterns before contacting your sales representative. • The list contains messages only for the server. For details about error messages of optional devices, and the actions to take, refer to the instructions that come with each product. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 111
A verify error (inconsistency between was detected when trying to read and write data) occurred while program data. writing into Flash ROM. (After that change destination to backup area by fault tolerant feature, and process is ongoing.) Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 112
(L0 Cache). 0001E33B CPU Internal Error was detected (L1 I-Cache). 0001E33C CPU Internal Error was detected (L1 D-Cache). 0001E33D CPU Internal Error was detected (L1 Cache). 0001E33E CPU Internal Error was detected (L2 I-Cache). Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 113
Contact your service representative. Jumper setting or weak battery. 0002E2EC The Setup Menu setting was BIOS Reset was executed from web This is not an error. cleared through the WEB UI. browser of EXPRESSSCOPE Engine SP3. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 114
Displayed while BIOS update is in progress. This is not an error. Wait until BIOS update Running is completed. BIOS Recovery Displayed while BIOS recovery is in This is not an error. Wait until BIOS Running progress. recovery is completed. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
When the system is used. system. (A different number replaces X depending on the system.) Warning A Reset command is issued to device \Device\RaidPort0. Megasr1 During Consistency Check This event does not affect system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 116
Unless the application event is registered after license authentication, 8198 this event does not affect system operation. Go to the following When installing an OS, running an OS Microsoft website for details. for the first time http://support.microsoft.com/kb/921471/en-us Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 117
Check to make sure the network cable is properly connected. Upon system startup or upon applying If the message appears upon system startup or upon applying Starter Starter Pack Pack, there is no problem in system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 118
Warning NtpClient will try again in 3473457 minutes and double the reattempt Time-Service interval thereafter. The error was: No such host is known. (0x80072AF9) Upon OS Installation This event does not affect system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 119
Microsoft-Windows-Use Warning {56EA1054-1959-467f-BE3B-A2A787C4B6EA} failed, error code is The Profiles Service revision level is unknown. 1534 Unless the application event is registered after license authentication, Upon OS Installation this event does not affect system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 120
Warning Auto-generating a self-signed certificate for server authentication. Hyper-V-VMMS 12520 This event is logged when activating Windows Server 2008 R2 Hyper-V, When the system is used. but this event does not affect system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 121
Shut down physical computer. Stopping/saving all virtual machines... Hyper-V-VMMS 14100 This event is logged when activating Windows Server 2008 R2 Hyper-V, When the system is used. but this event does not affect system operation. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
'WScript.Echo " Data LS Byte = 0x" & hex(outparams.ResponseData(1)) 'WScript.Echo " Data MS Byte = 0x" & hex(outparams.ResponseData(2)) WScript.Echo " Power Consumption = " & outparams.ResponseData(2)*256 + _ outparams.ResponseData(1) & " watts" End If ' End Script Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 123
Power Consumption = 76 watts The power consumption is 76 watts. Power consumption readings may not be acquired depending on the power supply Tips configuration of the server. The completion code in such cases is 0xC1 or 0xCB. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
GetSensorType(Reserve_LS, Reserve_MS, Record_LS, Record_MS, sensorType) If sensorType = 1 Then ' Temperature WScript.Echo "===========================================" call GetIDString(Reserve_LS, Reserve_MS, Record_LS, Record_MS) WScript.Echo " Sensor Type = Temperature" sensorNum = outparams.ResponseData(10) call GetSensor(Reserve_LS, Reserve_MS, Record_LS, Record_MS,sensorNum) End If Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 125
End If End Sub Sub get2complement(raw, rv, bit) Select Case bit case 4: If raw And &h8 Then rv = 0 - ((&h10 - raw) and &h0f) Else rv = raw End If case 8: Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 126
Ambient, or Front Panel. In the case of the sample above, the data is obtained from a sensor that contains Fnt Pnl Temp in its ID, with a resulting intake air temperature of 27°C. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
In such cases, either of the following messages is displayed. Unable to send RAW command (channel=0x0 netfn=0x3e lun=0x0 cmd=0xb rsp=0xc1): Invalid Command Unable to send RAW command (channel=0x0 netfn=0x3e lun=0x0 cmd=0xb rsp=0xcb): Requested sensor, data, or record not found Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
The sensor indicating intake air temperature contains Amb, Ambient, or Fnt Pnl Temp in its name. The data in the above example is obtained from the sensor that contains Fnt Pnl Temp in its ID and the intake air temperature is 27 ° C. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 132
All Rights Reserved. This program is licensed under the BSD license (the one with advertisement clause removed). If you are submitting changes to the project, please see CONTRIBUTIONS file for more instructions. License ------- Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 133
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 134
BSD License which accompanies this distribution. The full text of the license may be found at http://opensource.org/licenses/bsd-license.php THE PROGRAM IS DISTRIBUTED UNDER THE BSD LICENSE ON AN "AS IS" BASIS, WITHOUT WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 135
We wish to avoid the danger that redistributors of a free program will individually obtain patent licenses, in effect making the program proprietary. To prevent this, we have made it clear that any Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 136
Program is not required to print an announcement.) These requirements apply to the modified work as a whole. If identifiable sections of that work are not derived from the Program, Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 137
Program is void, and will automatically terminate your rights under this License. However, parties who have received copies, or rights, from you under this License will not have their licenses terminated so long as such Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 138
9. The Free Software Foundation may publish revised and/or new versions of the General Public License from time to time. Such new versions will be similar in spirit to the present version, but may differ in detail to Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 139
GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version. This program is distributed in the hope that it will be useful, Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 140
By contrast, the GNU General Public Licenses are intended to guarantee your freedom to share and change free software--to make sure the software is free for all its users. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 141
The Lesser General Public License permits more lax criteria for linking other code with the library. We call this license the "Lesser" General Public License because it Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 142
Activities other than copying, distribution and modification are not covered by this License; they are outside its scope. The act of Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 143
Thus, it is not the intent of this section to claim rights or contest your rights to work written entirely by you; rather, the intent is to exercise the right to control the distribution of derivative or collective works based on the Library. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 144
(Executables containing this object code plus portions of the Library will still fall under Section 6.) Otherwise, if the work is a derivative of the Library, you may distribute the object code for the work under the terms of Section 6. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 145
It may happen that this requirement contradicts the license restrictions of other proprietary libraries that do not normally accompany the operating system. Such a contradiction means you cannot Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 146
It is not the purpose of this section to induce you to infringe any Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 147
CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE LIBRARY (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 148
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/). This product includes cryptographic software written by Eric Young (eay@cryptsoft.com). LICENSE ISSUES ============== The OpenSSL toolkit stays under a dual license, i.e. both the conditions of Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 149
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED * OF THE POSSIBILITY OF SUCH DAMAGE. * ==================================================================== * This product includes cryptographic software written by Eric Young * (eay@cryptsoft.com). This product includes software written by Tim * Hudson (tjh@cryptsoft.com). Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 150
* The licence and distribution terms for any publically available version or * derivative of this code cannot be changed. i.e. this code cannot simply be * copied and put under another distribution licence * [including the GNU Public Licence.] Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 151
* and can be used freely for any purpose (the GNU license being the most * restrictive); see below for details. [However, none of that term is relevant at this point in time. All of Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 152
David Mazieres under a BSD-style license. * Copyright 1995, 1996 by David Mazieres <dm@lcs.mit.edu>. * Modification and redistribution in source and binary forms is * permitted provided that due credit is given to the author and the Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 153
Markus Friedl Theo de Raadt Niels Provos Dug Song Aaron Campbell Damien Miller Kevin Steves Daniel Kouril Wesley Griffin Per Allansson Nils Nordman Simon Wilkinson Portable OpenSSH additionally includes code from the following copyright Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 154
The Regents of the University of California Constantin S. Svintsoff * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions * are met: Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 155
* sale, use or other dealings in this Software without prior written * authorization. ****************************************************************************/ OpenSLP The following copyright and license is applicable to the entire OpenSLP project (libslp, slpd, and related documentation): Copyright (C) 2000 Caldera Systems, Inc Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 156
Redistribution and use in source and binary forms, with or without modification, are permitted provided that this notice is preserved. The names of the copyright holders may not be used to endorse or promote products derived from this software without their specific Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 157
* You can obtain a current copy of the Eclipse Public License from * http://www.opensource.org/licenses/eclipse-1.0.php /* ------------------------------------------------------------------------- */ /* Copyright (c) 2006 The Open Group /* Permission is hereby granted, free of charge, to any person obtaining a Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 158
* in documentation (online or textual) provided with the package. * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions * are met: Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 159
These notices must be retained in any copies of any part of this documentation and/or software. SHA1 * FIPS 180-2 SHA-224/256/384/512 implementation * Last update: 02/02/2007 * Issue date: 04/30/2005 * Copyright (C) 2005, 2007 Olivier Gay <olivier.gay@a3.epfl.ch> Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 160
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF * SUCH DAMAGE. ExploerCanvas js-tables Apache License Version 2.0, January 2004 Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 161
License, each Contributor hereby grants to You a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare Derivative Works of, publicly display, publicly perform, sublicense, and distribute the Work and such Derivative Works in Source or Object form. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 162
Work and reproducing the content of the NOTICE file. 7. Disclaimer of Warranty. Unless required by applicable law or agreed to in writing, Licensor provides the Work (and each Contributor provides its Contributions) on an "AS IS" BASIS, Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 163
Recipient (as defined in Article 1 below) constitutes the Recipient’s acceptance of this Agreement. Article 1 (Definitions) 1. “Digital Font Program” shall mean a computer program containing, or used to render or display fonts. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 164
7. The Recipient may create, use, reproduce and/or Redistribute a Derived Program under the terms stated above for the Licensed Program: provided, that the Recipient shall follow the provisions set forth in Article 3 Paragraph 1 when Redistributing the Derived Program. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 165
1. The term of this Agreement shall begin from the time of receipt of the Licensed Program by the Recipient and shall continue as long as the Recipient retains any such Licensed Program in any way. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...
Page 166
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide...