20
en | Control panel installation
3.
Figure 5.4: Mount control panel on standoffs
4.
5.2.2
Connect earth ground
5.2.3
Configure OUTPUT A using the jumper
When planning your installation, carefully consider the use of OUTPUT A. OUTPUT A is a form
C relay. You can configure the common terminal (C) of Output A (OUTPUT A) using the
jumper:
–
–
–
The control panel ships with the jumper in the default position, AUX power. (OUTPUT A, 'C'
terminal providing AUX PWR). To reconfigure the 'C' terminal as a COM terminal (parallel to all
COM terminals), remove the door covering the jumper pins, and move the jumper to the left
two pins. The OUTPUT A LED lights when OUTPUT A is active. Refer to the figure below or to
the Enclosure Wiring Label (B5512/B4512/B3512) to set the OUTPUT A jumper.
Figure 5.5: OUTPUT A jumper configuration options (B5512 shown)
2017.04 | 15 | F.01U.287.180
Place the control panel on top of the standoffs. Align the holes in the corners of the
control panel with the openings at the top of each standoff. Secure the control panel to
the standoffs with supplied, self-threading screws.
If using the B12 Mounting Plate for D8103 Enclosure, rest the hook tabs on the mounting
plate hooks within the enclosure. Secure the lock-down tab to the plate mounting hole
with the screw provided.
To provide +12 VDC (AUX power)
To be a COM terminal (parallel to all COM terminals)
To be a dry contact (no voltage, not common)
OUTPUT A (C terminal) = AUX PWR
P1
COM AUX
OUTPUT A (C terminal) = COM
P1
COM AUX
OUTPUT A (C terminal) = DRY
P1
COM AUX
18 VAC
18VAC
+ BAT -
COMMUNICATION MODULE 1
P1
COM AUX
SDI2
Device Bus
R Y G B
AUX
OUTPUT A
- 12 V +
NO C NC
COM AUX
R
Y
G
PWR A
B COM
OUTPUT A
Installation Manual
100BASE-T
LINK
ON-BOARD POINTS
Voltage Ranges
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
1 k
End of Line Resistors
1 COM 2
3 COM 4 5 COM 6
B
1
COM
2
3
COM
4
5
COM
6
Bosch Security Systems, Inc.
Control Panels
ETHERNET
USB
C
OUTPUT
B
7 COM 8
7
COM
8