hit counter script

Bosch VG5-7230-CPT5 Operation Manual page 51

Hide thumbs Also See for VG5-7230-CPT5:
Table of Contents

Advertisement

AUTODOME IP starlight 7000 HD
Ref. Description
9
10
11
12
The Pipe Interface Board contains all of the connectors for control, data, image, and power
wires. Follow the procedures below to make the proper connections.
Warning!
Use a 24 VAC Class 2 power supply only.
!
1.
2.
3.
Caution!
To protect the camera from damage due to cold temperatures, ensure that you connect the
!
24 VAC heater power wires to the P101 connector.
Connecting Alarm Inputs and Outputs
4
Figure 8.26: Alarm and relay connectors
Bosch Security Systems
Connector Wire
Dome Power
P101
Heater Power
P107
RJ45 Ethernet
J101
To camera
Attach an RJ45 connector plug to the Ethernet cable and connect the plug to its mating
connector J101 on the Pipe Interface Board.
Attach the control data in/out wires to their respective terminals on the P105 connector
on the Pipe Interface Board.
Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board. If
this model has a heater, connect the 24 VAC heater power wires to connector P107.
To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm
wires. Alarm Out 4 is a relay.
PIN
1
2
3
4
PIN
1
2
3
4
5
6
Installing the Roof Parapet and Pipe Mounts | en
Pin Description
Gauge
AWG
3
Dome 24 VAC
18-14
2
Earth Ground
1
Dome 24 VAC
AWG
2
Heater 24 VAC
18-14
1
Heater 24 VAC
WHITE
BROWN
ORANGE
GREEN
WHITE
BROWN
ORANGE
GREEN
YELLOW
BLUE
Operation Manual
P102
P103
2016-07 | 1.0 | F.01U.283.679
51
1
2
3
4
5
6
7
P104