hit counter script
Miele DA 362-75 Operating And Installation Instructions
Miele DA 362-75 Operating And Installation Instructions

Miele DA 362-75 Operating And Installation Instructions

Hide thumbs Also See for DA 362-75:

Advertisement

Operating and Installation
Instructions
Ventilation System
DA 362-75
DA 362-110
UV
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
M.-Nr. 06 191 500

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 362-75

  • Page 1 Operating and Installation Instructions Ventilation System DA 362-75 DA 362-110 To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 06 191 500...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the hood Operation Main power switch ..........10 Joystick .
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is designed to vent This appliance is intended for cooking smoke and odors only. residential use only. Use the Be certain your appliance is appliance only for its intended properly installed and grounded by purpose.
  • Page 4 Supervise its use by the conditions it may be possible for an elderly or infirm. installation in these applications. Please contact the nearest Miele dealer or the Be careful when preparing a Technical Service Department with flambé beneath the hood.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS , WARNING - TO REDUCE , WARNING TO REDUCE THE RISK OF INJURY THE RISK OF A RANGE TOP TO PERSONS IN THE EVENT OF A GREASE FIRE: RANGE TOP GREASE FIRE, Never leave surface units OBSERVE THE FOLLOWING: unattended at high settings.
  • Page 6 When installing the hood, follow the an active chimney, dryer vent, vent recommended minimum safety flue, or room ventilating ductwork. Seek distances between a Miele cooktop and professional advice before connecting the hood: an exhaust hood vent to an existing, –...
  • Page 7: Functional Description

    The active charcoal filters may be room air can occur. purchased from your Miele dealer or Miele’s Technical Service Department. When the hood is turned on, the air pressure of the exhaust fan auto-...
  • Page 8: Guide To The Hood

    Guide to the hood...
  • Page 9: Grease Filter

    – to show how long the grease filters additional accessory have been in use (see "Operation / Filter timers"). DA 362-75 two filters DA 362-110 four filters – to change the number of hours counted by the grease filter timer e Main power switch (see "Operation / Reprogramming the...
  • Page 10: Main Power Switch

    Operation Main power switch Joystick only for the DA 362-110 Press the main power switch to "l" to use the fan and lighting. If the appliance is not going to be used for a long period of time (e.g. while vacationing) it should be turned off ("0") at the main power switch.
  • Page 11: Turning On The Fan

    Fan performance Selecting the power level DA 362-75: The maximum air flow capacity is ^ Press the joystick to the right, to 425 cfm. Factors such as narrow duct increase the fan speed.
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down Overhead lighting If odors or smoke remain in the kitchen The overhead lighting can be turned on after cooking has been completed, the and off independently of the fan. Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes.
  • Page 13: Filter Timers

    Operation Filter timers Checking the filter timers To check the percentage of time set Grease filter timer already used: A timer monitors the hours of operation. ^ Press the joystick to the left to turn The indicator for the grease filter will the fan on.
  • Page 14: Reprogramming The Timers

    Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. The indicators of the fan power scale – A time of 20 hours should be show the programmed time: programmed in kitchens with 1st indicator from the left = 20 hours...
  • Page 15 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and can not be used to exhaust fumes. The charcoal filter timer is not preset. Before using the hood in recirculation mode, the charcoal filter timer must be programmed.
  • Page 16: Cleaning And Care

    Cleaning and care Stainless steel Before cleaning or servicing the Stainless steel surfaces can be cleaned hood, disconnect it from the power using a non-abrasive stainless steel supply by either removing the fuse, cleaner. unplugging it from the outlet or manually "tripping"...
  • Page 17: Grease Filters

    Cleaning and care Grease filters Cleaning the grease filters ^ Clean the filters: The reusable metal grease filters remove solid particles from the vented – by hand: use a scrub brush in warm kitchen air (grease, dust, etc). water with a mild detergent. –...
  • Page 18 Cleaning and care Inserting the grease filters When putting the grease filters back make sure that the locking clips are visible facing down towards the cooking surface. If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing.
  • Page 19: Active Charcoal Filters

    Cleaning and care Active charcoal filters Before using: ^ Program the charcoal filter timer, see In recirculation mode four active charcoal filters must be used in "Operation/Reprogramming the addition to the grease filters. The charcoal filter timer". charcoal filters are designed to absorb cooking odors.
  • Page 20: Changing The Light Bulb

    Cleaning and care Changing the light bulb Before changing the light bulb, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become ^ Turn the bulb to the left and pull it extremely hot, and they can burn your hands.
  • Page 21: After Sales Service

    After Sales Service In the event of a fault which you can not correct yourself please contact the Miele Technical Service Department 1-800-999-1360 techserv@mieleusa.com 1-800-565-6435 service@miele.ca When contacting the Technical Service Department, please quote the model and serial number of your appliance.
  • Page 23: Installation Instructions

    Installation Instructions...
  • Page 24: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling authority about the be biodegradable and recyclable.
  • Page 25: Electrical Data

    Installation, repairs and other work 120 VAC, 60 Hz, 15 A power outlet. by unqualified persons could be DA 362-75: dangerous. The manufacturer can Maximum load ....320 W not be held responsible for Fan.
  • Page 26: Appliance Dimensions

    Appliance dimensions DA 362-75 *Cut out dimensions A depth T, min. 1 " (40 mm), is necessary in the rear of the cabinet.
  • Page 27: Appliance Dimensions

    Appliance dimensions DA 362-110 *Cut out dimensions A depth T, min. 1 " (40 mm), is necessary in the rear of the cabinet.
  • Page 28: Installation

    Installation Do not install this hood over any appliance that burns solid fuel. The minimum safety distance allowed between the top of a Miele cooking surface and the bottom of the hood is: – 22" (55 cm) above electric cooktops –...
  • Page 29: Installation

    Installation The hood is designed to be installed within cabinetry and kitchen islands. The top half (motor and fan assembly) should be accessible after installation. If the motor and fan assembly are not accessible, assemble the ductwork and the electical connection before the installation.
  • Page 30: Air Extraction Mode

    Installation Air extraction mode Exhaust connection ^ Connect the ductwork to the exhaust Non-return flaps connection using appropriate measures for the type of ductwork being installed (hose clamp, duct tape, etc.). Note: A Y- adapter is supplied with the DA 362-110. It may be used to feed the exhaust from both connections to a common duct.
  • Page 31: Recirculation Mode

    For recirculation mode the following accessories can be ordered from your Miele dealer or the Technical Service Department: For DA 362-75: – 1 conversion kit ^ The reducing collar must be used in for recirculation recirculation mode.
  • Page 32 Installation ^ DA 362-75: Recirculation connection In recirculation mode, one cut out must be made, where the ducting ends, for the installation of the recirculation vents, b. If installing the hood over an island or in a cabinet at ceiling height, a suitable cut-out has to be made in the front panel, d.
  • Page 33: Installing The Joystick

    Installation Installing the joystick Joystick extension The joystick can be extended for an easier reach. ^ Attach the lower part of the joystick to the extension with a spring washer. Turn the m-symbol to the front and ^ Insert the lower half of the desired joystick into the socket, loosely screw in place with an allen wrench while using a wrench to counter the...
  • Page 34: Electrical Connection

    Installation Electrical connection Before connecting the appliance to power read the "Important Safety Instructions". ^ Plug in the power cord. ^ Before using the appliance remove the grease filters and remove the protective foil from the filter frame. Insert the grease filters back into place.
  • Page 35: Air Extraction

    – The extraction ducting should be as – If the exhaust is ducted through an short and straight as possible, and outside wall, a Miele Telescopic Wall the number of sharp bends should Vent can be used. be minimized.
  • Page 36 Air extraction Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important: If the ductwork runs through rooms, ceilings, garages, etc.
  • Page 40 Alteration rights reserved / 2204 M.-Nr. 06 191 500 / 01 This paper was bleached without the use of chlorine.

This manual is also suitable for:

Da 362-110

Table of Contents